summaryrefslogtreecommitdiff
path: root/.pc/03_usb-db.diff
diff options
context:
space:
mode:
authorJörg Frings-Fürst <debian@jff-webhosting.net>2014-09-01 13:56:46 +0200
committerJörg Frings-Fürst <debian@jff-webhosting.net>2014-09-01 13:56:46 +0200
commit22f703cab05b7cd368f4de9e03991b7664dc5022 (patch)
tree6f4d50beaa42328e24b1c6b56b6ec059e4ef21a5 /.pc/03_usb-db.diff
Initial import of argyll version 1.5.1-8debian/1.5.1-8
Diffstat (limited to '.pc/03_usb-db.diff')
-rw-r--r--.pc/03_usb-db.diff/usb/55-Argyll.rules90
1 files changed, 90 insertions, 0 deletions
diff --git a/.pc/03_usb-db.diff/usb/55-Argyll.rules b/.pc/03_usb-db.diff/usb/55-Argyll.rules
new file mode 100644
index 0000000..3da9c69
--- /dev/null
+++ b/.pc/03_usb-db.diff/usb/55-Argyll.rules
@@ -0,0 +1,90 @@
+# udev rule to recognize instruments and make them accessible to user applications.
+# Copy this to /etc/udev/rules.d/55-Argyll.rules
+
+# Skip all this to speed things up if it'a not a usb add.
+ACTION!="add", GOTO="argyll_rules_end"
+SUBSYSTEM!="usb", GOTO="argyll_rules_end"
+
+# Recognize the color measurement devices
+
+# Colorimtre HCFR
+ATTRS{idVendor}=="04db", ATTRS{idProduct}=="005b", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+
+# MonacoOPTIX (Same as i1 Display 1)
+ATTRS{idVendor}=="0670", ATTRS{idProduct}=="0001", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+
+# HueyL (not tested)
+ATTRS{idVendor}=="0765", ATTRS{idProduct}=="5001", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+# HueyL (not tested)
+ATTRS{idVendor}=="0765", ATTRS{idProduct}=="5010", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+# i1Display 3
+ATTRS{idVendor}=="0765", ATTRS{idProduct}=="5020", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+# ColorMunki Smile
+ATTRS{idVendor}=="0765", ATTRS{idProduct}=="6003", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+# DTP20
+ATTRS{idVendor}=="0765", ATTRS{idProduct}=="d020", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+# DTP92Q (not tested)
+ATTRS{idVendor}=="0765", ATTRS{idProduct}=="d092", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+# DTP94
+ATTRS{idVendor}=="0765", ATTRS{idProduct}=="d094", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+
+# i1Pro
+ATTRS{idVendor}=="0971", ATTRS{idProduct}=="2000", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+# i1Monitor
+ATTRS{idVendor}=="0971", ATTRS{idProduct}=="2001", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+# i1Display
+ATTRS{idVendor}=="0971", ATTRS{idProduct}=="2003", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+# i1 io table (not tested)
+ATTRS{idVendor}=="0971", ATTRS{idProduct}=="2004", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+# Huey
+ATTRS{idVendor}=="0971", ATTRS{idProduct}=="2005", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+# i1 iSis (not tested)
+ATTRS{idVendor}=="0971", ATTRS{idProduct}=="2006", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+# ColorMunki
+ATTRS{idVendor}=="0971", ATTRS{idProduct}=="2007", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+
+# Spyder 1
+ATTRS{idVendor}=="085c", ATTRS{idProduct}=="0100", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+# Spyder 2
+ATTRS{idVendor}=="085c", ATTRS{idProduct}=="0200", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+# Spyder 3
+ATTRS{idVendor}=="085c", ATTRS{idProduct}=="0300", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+# Spyder 4
+ATTRS{idVendor}=="085c", ATTRS{idProduct}=="0400", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+
+# ColorHug, old and new
+ATTRS{idVendor}=="04d8", ATTRS{idProduct}=="f8da", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+ATTRS{idVendor}=="273f", ATTRS{idProduct}=="1001", ENV{COLOR_MEASUREMENT_DEVICE}="1"
+
+
+# Let udev-acl manage these devices, if it's available
+TEST=="/var/run/ConsoleKit/database", ENV{COLOR_MEASUREMENT_DEVICE}=="*?", ENV{ACL_MANAGE}="1"
+
+# Otherwise, restrict access to members of the plugdev group,
+# which the user may have to add to the system.
+ENV{COLOR_MEASUREMENT_DEVICE}=="*?", ENV{ACL_MANAGE}!="*?", MODE="660", GROUP="plugdev"
+
+# Set ID_VENDOR and ID_MODEL acording to VID and PID
+IMPORT{program}="usb-db %p"
+
+LABEL="argyll_rules_end"