diff options
author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-09-07 13:29:54 +0200 |
---|---|---|
committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-09-07 13:29:54 +0200 |
commit | a879b4e708b3e46c9697ba6581687eeb5b02a320 (patch) | |
tree | f85acc5cb1a7c0b03a050c879c20cab3deb9f40e /debian/man/spec2cie.1 | |
parent | 556dffcdad42b938bc196819aa463247de709765 (diff) | |
parent | c07d0c2d2f6f7b0eb6e92cc6204bf05037957e82 (diff) |
state from 2014-09-07 13:30 MESZ
Diffstat (limited to 'debian/man/spec2cie.1')
-rw-r--r-- | debian/man/spec2cie.1 | 84 |
1 files changed, 84 insertions, 0 deletions
diff --git a/debian/man/spec2cie.1 b/debian/man/spec2cie.1 new file mode 100644 index 0000000..9bd7068 --- /dev/null +++ b/debian/man/spec2cie.1 @@ -0,0 +1,84 @@ +.\" DO NOT MODIFY THIS FILE! It was generated by help2man 1.44.1. +.TH CONVERT "1" "September 2014" "Convert spectral .ti3 file, Version 1.6.3" "User Commands" +.SH NAME +Convert \- Convert spectral .ti3 file. +.SH SYNOPSIS +.B spec2cie +[\fIoptions\fR] \fIinput.ti3 output.ti3\fR +.SH DESCRIPTION +Convert spectral .ti3 file, Version 1.6.3 +Author: Gerhard Fuernkranz, licensed under the AGPL Version 3 +.TP +\fB\-v\fR +Verbose mode +.TP +\fB\-I\fR illum +Override actual instrument illuminant in .ti3 file: +.IP +A, C, D50, D50M2, D65, F5, F8, F10 or file.sp +(only used in conjunction with \fB\-f\fR) +.TP +\fB\-f\fR [illum] +Use Fluorescent Whitening Agent compensation [simulated inst. illum.: +.IP +M0, M1, M2, A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp] +.TP +\fB\-i\fR illum +Choose illuminant for computation of CIE XYZ from spectral data & FWA: +A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp +.TP +\fB\-o\fR observ +Choose CIE Observer for spectral data: +.IP +1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2 +.TP +\fB\-n\fR +Don't output spectral values +.TP +\fB\-p\fR +Plot each values spectrum +.TP +input.ti3 +Measurement file +.TP +output.ti3 +Converted measurement file +.PP +Author: Gerhard Fuernkranz, licensed under the AGPL Version 3 +.PP +Usage: spec2cie [options] input.ti3 output.ti3 +.TP +\fB\-v\fR +Verbose mode +.TP +\fB\-I\fR illum +Override actual instrument illuminant in .ti3 file: +.IP +A, C, D50, D50M2, D65, F5, F8, F10 or file.sp +(only used in conjunction with \fB\-f\fR) +.TP +\fB\-f\fR [illum] +Use Fluorescent Whitening Agent compensation [simulated inst. illum.: +.IP +M0, M1, M2, A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp] +.TP +\fB\-i\fR illum +Choose illuminant for computation of CIE XYZ from spectral data & FWA: +A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp +.TP +\fB\-o\fR observ +Choose CIE Observer for spectral data: +.IP +1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2 +.TP +\fB\-n\fR +Don't output spectral values +.TP +\fB\-p\fR +Plot each values spectrum +.TP +input.ti3 +Measurement file +.TP +output.ti3 +Converted measurement file |