diff options
author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-09-01 13:56:46 +0200 |
---|---|---|
committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-09-01 13:56:46 +0200 |
commit | 22f703cab05b7cd368f4de9e03991b7664dc5022 (patch) | |
tree | 6f4d50beaa42328e24b1c6b56b6ec059e4ef21a5 /debian/spec2cie.1 |
Initial import of argyll version 1.5.1-8debian/1.5.1-8
Diffstat (limited to 'debian/spec2cie.1')
-rw-r--r-- | debian/spec2cie.1 | 84 |
1 files changed, 84 insertions, 0 deletions
diff --git a/debian/spec2cie.1 b/debian/spec2cie.1 new file mode 100644 index 0000000..1ec3695 --- /dev/null +++ b/debian/spec2cie.1 @@ -0,0 +1,84 @@ +.\" DO NOT MODIFY THIS FILE! It was generated by help2man 1.43.3. +.TH CONVERT "1" "August 2013" "Convert spectral .ti3 file, Version 1.5.1" "User Commands" +.SH NAME +Convert \- Convert spectral .ti3 file. +.SH SYNOPSIS +.B spec2cie +[\fIoptions\fR] \fIinput.ti3 output.ti3\fR +.SH DESCRIPTION +Convert spectral .ti3 file, Version 1.5.1 +Author: Gerhard Fuernkranz, licensed under the AGPL Version 3 +.TP +\fB\-v\fR +Verbose mode +.TP +\fB\-I\fR illum +Override actual instrument illuminant in .ti3 file: +.IP +A, C, D50, D50M2, D65, F5, F8, F10 or file.sp +(only used in conjunction with \fB\-f\fR) +.TP +\fB\-f\fR [illum] +Use Fluorescent Whitening Agent compensation [simulated inst. illum.: +.IP +M0, M1, M2, A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp] +.TP +\fB\-i\fR illum +Choose illuminant for computation of CIE XYZ from spectral data & FWA: +A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp +.TP +\fB\-o\fR observ +Choose CIE Observer for spectral data: +.IP +1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2 +.TP +\fB\-n\fR +Don't output spectral values +.TP +\fB\-p\fR +Plot each values spectrum +.TP +input.ti3 +Measurement file +.TP +output.ti3 +Converted measurement file +.PP +Author: Gerhard Fuernkranz, licensed under the AGPL Version 3 +.PP +Usage: spec2cie [options] input.ti3 output.ti3 +.TP +\fB\-v\fR +Verbose mode +.TP +\fB\-I\fR illum +Override actual instrument illuminant in .ti3 file: +.IP +A, C, D50, D50M2, D65, F5, F8, F10 or file.sp +(only used in conjunction with \fB\-f\fR) +.TP +\fB\-f\fR [illum] +Use Fluorescent Whitening Agent compensation [simulated inst. illum.: +.IP +M0, M1, M2, A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp] +.TP +\fB\-i\fR illum +Choose illuminant for computation of CIE XYZ from spectral data & FWA: +A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp +.TP +\fB\-o\fR observ +Choose CIE Observer for spectral data: +.IP +1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2 +.TP +\fB\-n\fR +Don't output spectral values +.TP +\fB\-p\fR +Plot each values spectrum +.TP +input.ti3 +Measurement file +.TP +output.ti3 +Converted measurement file |