@@ -31,6 +31,9 @@
+
+
+
&nbsp; &nbsp; &nbsp; Verbose mode</span><br style="font-family:
monospace;">
<span style="font-family: monospace;"></span><span
@@ -52,6 +55,9 @@
+
+
+
&nbsp; &nbsp; &nbsp; Print spectrum for each reading.</span></small><br
style="font-family: monospace;">
<small><span style="font-family: monospace;"></span><span
@@ -78,6 +84,9 @@
+
+
+
Set COM port, 1..4 (default 1)</span><span style="font-family:
monospace;"></span><span style="font-family: monospace;"><br
style="font-family: monospace;">
@@ -98,6 +107,9 @@
+
+
+
&nbsp; &nbsp; &nbsp; Use transmission measurement mode</span><br
style="font-family: monospace;">
<span style="font-family: monospace;">&nbsp;</span><a style="
@@ -118,6 +130,9 @@
+
+
+
Use emissive measurement mode (absolute results)<br>
</span></small><small><span style="font-family: monospace;">&nbsp;</span><a
style=" font-family: monospace;" href="#eb">-eb</a><span
@@ -137,26 +152,15 @@
+
+
+
Use display white brightness relative measurement mode<br>
</span></small><small><span style="font-family: monospace;">&nbsp;</span><a
style=" font-family: monospace;" href="#ew">-ew</a><span
style="font-family: monospace;">
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Use display white relative measurement mode<br>
+ Use display white point relative chromatically adjusted mode<br>
</span></small><small><span style="font-family: monospace;">&nbsp;</span><a
style=" font-family: monospace;" href="#p">-p</a><span
style="font-family: monospace;">
@@ -175,6 +179,9 @@
+
+
+
Use telephoto measurement mode (absolute results)<br>
</span></small><small><span style="font-family: monospace;">&nbsp;</span><a
style=" font-family: monospace;" href="#pb">-pb</a><span
@@ -194,6 +201,9 @@
+
+
+
Use </span></small><small><span style="font-family: monospace;">projector</span></small><small><span
style="font-family: monospace;"> white brightness relative
measurement mode<br>
@@ -215,9 +225,13 @@
+
+
+
Use </span></small><small><span style="font-family: monospace;">projector</span></small><small><span
- style="font-family: monospace;"> white relative measurement mode</span></small><small><span
- style="font-family: monospace;"></span></small><br>
+ style="font-family: monospace;"> </span></small><small><span
+ style="font-family: monospace;">white point relative
+ chromatically adjusted mode</span></small><br>
<small><span style="font-family: monospace;">&nbsp;</span><a
style="font-family: monospace;" href="#a">-a</a><span
style="font-family: monospace;">
@@ -236,6 +250,9 @@
+
+
+
Use ambient measurement mode (absolute results)<br>
&nbsp;<a href="#f">-f</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
@@ -252,6 +269,9 @@
+
+
+
Use ambient flash measurement mode (absolute results)<br>
</span></small><font size="-1"><span style="font-family:
monospace;">&nbsp;<a href="#y">-y X</a>
@@ -270,6 +290,9 @@
+
+
+
Display type - instrument specific list to choose from.</span></font><br>
<small><span style="font-family: monospace;">&nbsp;</span><a
style="font-family: monospace;" href="spotread.html#I">-I illum</a><span
@@ -286,6 +309,9 @@
&nbsp;&nbsp;
M0,
+
+
+
M1, M2, A, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp</span></small><br
style="font-family: monospace;">
<small><span style="font-family: monospace;"></span><span
@@ -319,6 +345,9 @@ D50
+
+
+
D50M2, D65, F5, F8, F10 or file.sp</span><br style="font-family:
monospace;">
<span style="font-family: monospace;">&nbsp;</span><a style="
@@ -342,6 +371,9 @@ D50
+
+
+
&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp; </span></small><small><span
style="font-family: monospace;">1931_2 </span></small><small><span
style="font-family: monospace;"> (def.)</span></small><small><span
@@ -364,6 +396,9 @@ D50
+
+
+
Set filter configuration:<br>
&nbsp;&nbsp;
n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
@@ -381,6 +416,9 @@ D50
+
+
+
None<br>
&nbsp;&nbsp;
p&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
@@ -398,6 +436,9 @@ D50
+
+
+
Polarising filter<br>
&nbsp;&nbsp;
6&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
@@ -415,6 +456,9 @@ D50
+
+
+
D65<br>
&nbsp;&nbsp;
u&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
@@ -432,6 +476,9 @@ D50
+
+
+
U.V. Cut<br>
&nbsp;<a href="#E">-E extrafilterfile</a>&nbsp;&nbsp;&nbsp;
Apply extra filter compensation file<br>
@@ -452,6 +499,9 @@ D50
+
+
+
Display Yxy instead of Lab<br>
</span></font><font size="-1"><span style="font-family:
monospace;">&nbsp;<a href="#h">-h</a>
@@ -470,6 +520,9 @@ D50
+
+
+
Display LCh instead of Lab</span></font><br>
<font size="-1"><span style="font-family: monospace;">&nbsp;<a
href="#V">-V</a>
@@ -488,6 +541,9 @@ D50
+
+
+
Show running average and std. devation from ref.</span></font><br>
<font size="-1"><span style="font-family: monospace;">&nbsp;<a
href="#T">-T</a>
@@ -506,6 +562,9 @@ D50
+
+
+
Display correlated color temperatures and CRI<br>
</span></font><font size="-1"><span style="font-family:
monospace;">&nbsp;<a href="#N">-N</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
@@ -523,6 +582,9 @@ D50
+
+
+
Disable initial calibration of instrument if possible</span></font><br>
<font size="-1"><span style="font-family: monospace;">&nbsp;</span><a
style="font-family: monospace;" href="#H">-H</a><span
@@ -546,6 +608,9 @@ D50
+
+
+
Apply Colorimeter Correction Matrix</span></font><br>
<span style="font-family: monospace;">&nbsp;<a href="#X2">-X
file.ccss</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
@@ -568,6 +633,9 @@ Samples
+
+
+
for calibration</span><br>
<font size="-1"><span style="font-family: monospace;">&nbsp;</span><a
style=" font-family: monospace;" href="#Yrn">-<font size="-1">Y</font>
@@ -579,14 +647,20 @@ Samples
+
+
+
&nbsp;&nbsp;&nbsp;&nbsp; Override refresh, non-refresh display
mode</span></font><br>
+ <tt>&nbsp;<a href="#YR">-Y R:<i>rate</i></a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
+
+ Override measured refresh rate with rate Hz</tt><br>
<font size="-1"><span style="font-family: monospace;">&nbsp;</span><a
- style=" font-family: monospace;" href="#YA">-<font size="-1">Y</font>A</a><span
+ style=" font-family: monospace;" href="#YA">-<font size="-1">Y </font>A</a><span
style="font-family: monospace;">
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
- &nbsp;&nbsp;&nbsp;&nbsp; Use non-adaptive integration time mode
- (if available).</span></font><br>
+ &nbsp;&nbsp;&nbsp; Use non-adaptive integration time mode (if
+ available).</span></font><br>
<font size="-1"><span style="font-family: monospace;">&nbsp;<a
href="#W">-W n|h|x</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Override
@@ -611,6 +685,9 @@ none,
+
+
+
h = HW, x = Xon/Xoff</span></font><br>
<small><span style="font-family: monospace;">&nbsp;</span><a style="
font-family: monospace;" href="#D">-D [level]</a><span
@@ -633,6 +710,9 @@ none,
+
+
+
Optional file to save reading results<br style="font-family:
monospace;">
</span></font><small><span style="font-family: monospace;"></span><span
@@ -695,7 +775,9 @@ none,
<a name="ew"></a>The <span style="font-weight: bold;">-ew</span>
flag allows measuring in emissive mode using instruments that
support this mode, with the reading being relative to the white
- value read as the first reading.<br>
+ value read as the first reading using a Bradford chromatic adaption.
+ This matches the absolute &lt;-&gt; relative intent transformation
+ of Argyll ICC profiles.<br>
<br>
<a name="p"></a>The <span style="font-weight: bold;">-p</span> flag
allows measuring in telephoto mode, using instruments that support
@@ -714,7 +796,9 @@ none,
<a name="pw"></a>The <span style="font-weight: bold;">-pw</span>
flag allows measuring in telephoto mode using instruments that
support this mode, with the reading being relative to the white
- value read as the first reading.<br>
+ value read as the first reading using a Bradford chromatic adaption.
+ This matches the absolute &lt;-&gt; relative intent transformation
+ of Argyll ICC profiles.<br>
<br>
<a name="a"></a>The <span style="font-weight: bold;">-a</span> flag
allows measuring in ambient illumination mode using instruments that
@@ -749,9 +833,9 @@ none,
and how this works, see <a href="instruments.html">Operation of
particular instruments</a>. <b>3)</b> Any installed CCSS files
(if applicable), or CCMX files. These files are typically created
- using <a href="file:///D:/src/argyll/doc/ccxxmake.html">ccxxmake</a>,
+ using <a href="ccxxmake.html">ccxxmake</a>,
and installed using <a
- href="file:///D:/src/argyll/doc/oeminst.html">oeminst</a>. The
+ href="oeminst.html">oeminst</a>. The
default and Base Calibration types will be indicated in the usage.<br>
<br>
<a name="I"></a>The <b>-I</b> parameter allows specifying a
@@ -883,6 +967,9 @@ a
+
+
+
colorimeters accuracy for a particular type of display.<br>
<br>
<a name="Yrn"></a> The -<span style="font-weight: bold;">Y r </span>and
@@ -892,6 +979,9 @@ a
+
+
+
<b>-Y n</b> options overrides the refresh display mode set by the <a
href="#y">-y display type selection</a>, with <b>-Y</b><span
style="font-weight: bold;"> r</span> forcing refresh display mode,
@@ -899,6 +989,12 @@ a
instruments support a display measurement refresh mode, or the
ability to override the mode set by the display type selection.<br>
<br>
+ <a name="YR"></a> The -<span style="font-weight: bold;">Y R:<i>rate</i></span><b></b>
+ options overrides calibration of the instrument refresh rate. This
+ may be useful if the instrument supports this function and the
+ refresh rate cannot be accurately calibrated from the display
+ itself.<br>
+ <br>
<a name="YA"></a> The -<span style="font-weight: bold;">Y A</span>
option uses a non-adaptive integration time emission measurement
mode, if the instrument supports it, such as the Eye-One Pro or
@@ -975,6 +1071,10 @@ a
can be toggled on and off using the <span style="font-weight:
bold;">h</span> key.<br>
<br>
+ If the instrument supports a laser target (such as the JETI
+ specbos), then this can be toggled on &amp; off using the <b>t</b>
+ key. It will automatically be turned off at each measurement.<br>
+ <br>
If the instrument supports stored readings (ie. DTP20), then these
can be ignored using the <span style="font-weight: bold;">n</span>
key.<br>