diff options
author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-09-01 15:43:52 +0200 |
---|---|---|
committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-09-01 15:43:52 +0200 |
commit | c07d0c2d2f6f7b0eb6e92cc6204bf05037957e82 (patch) | |
tree | 41791cbe367cf023b98043fee56f9346b2592b49 /doc/spotread.html | |
parent | d7f89e6fe63b8697fab5a901cfce457b375638b3 (diff) |
Imported Upstream version 1.6.3upstream/1.6.3
Diffstat (limited to 'doc/spotread.html')
-rw-r--r-- | doc/spotread.html | 148 |
1 files changed, 124 insertions, 24 deletions
diff --git a/doc/spotread.html b/doc/spotread.html index 0259530..aaac0a1 100644 --- a/doc/spotread.html +++ b/doc/spotread.html @@ -31,6 +31,9 @@ + + + Verbose mode</span><br style="font-family: monospace;"> <span style="font-family: monospace;"></span><span @@ -52,6 +55,9 @@ + + + Print spectrum for each reading.</span></small><br style="font-family: monospace;"> <small><span style="font-family: monospace;"></span><span @@ -78,6 +84,9 @@ + + + Set COM port, 1..4 (default 1)</span><span style="font-family: monospace;"></span><span style="font-family: monospace;"><br style="font-family: monospace;"> @@ -98,6 +107,9 @@ + + + Use transmission measurement mode</span><br style="font-family: monospace;"> <span style="font-family: monospace;"> </span><a style=" @@ -118,6 +130,9 @@ + + + Use emissive measurement mode (absolute results)<br> </span></small><small><span style="font-family: monospace;"> </span><a style=" font-family: monospace;" href="#eb">-eb</a><span @@ -137,26 +152,15 @@ + + + Use display white brightness relative measurement mode<br> </span></small><small><span style="font-family: monospace;"> </span><a style=" font-family: monospace;" href="#ew">-ew</a><span style="font-family: monospace;"> - - - - - - - - - - - - - - - Use display white relative measurement mode<br> + Use display white point relative chromatically adjusted mode<br> </span></small><small><span style="font-family: monospace;"> </span><a style=" font-family: monospace;" href="#p">-p</a><span style="font-family: monospace;"> @@ -175,6 +179,9 @@ + + + Use telephoto measurement mode (absolute results)<br> </span></small><small><span style="font-family: monospace;"> </span><a style=" font-family: monospace;" href="#pb">-pb</a><span @@ -194,6 +201,9 @@ + + + Use </span></small><small><span style="font-family: monospace;">projector</span></small><small><span style="font-family: monospace;"> white brightness relative measurement mode<br> @@ -215,9 +225,13 @@ + + + Use </span></small><small><span style="font-family: monospace;">projector</span></small><small><span - style="font-family: monospace;"> white relative measurement mode</span></small><small><span - style="font-family: monospace;"></span></small><br> + style="font-family: monospace;"> </span></small><small><span + style="font-family: monospace;">white point relative + chromatically adjusted mode</span></small><br> <small><span style="font-family: monospace;"> </span><a style="font-family: monospace;" href="#a">-a</a><span style="font-family: monospace;"> @@ -236,6 +250,9 @@ + + + Use ambient measurement mode (absolute results)<br> <a href="#f">-f</a> @@ -252,6 +269,9 @@ + + + Use ambient flash measurement mode (absolute results)<br> </span></small><font size="-1"><span style="font-family: monospace;"> <a href="#y">-y X</a> @@ -270,6 +290,9 @@ + + + Display type - instrument specific list to choose from.</span></font><br> <small><span style="font-family: monospace;"> </span><a style="font-family: monospace;" href="spotread.html#I">-I illum</a><span @@ -286,6 +309,9 @@ M0, + + + M1, M2, A, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp</span></small><br style="font-family: monospace;"> <small><span style="font-family: monospace;"></span><span @@ -319,6 +345,9 @@ D50 + + + D50M2, D65, F5, F8, F10 or file.sp</span><br style="font-family: monospace;"> <span style="font-family: monospace;"> </span><a style=" @@ -342,6 +371,9 @@ D50 + + + </span></small><small><span style="font-family: monospace;">1931_2 </span></small><small><span style="font-family: monospace;"> (def.)</span></small><small><span @@ -364,6 +396,9 @@ D50 + + + Set filter configuration:<br> n @@ -381,6 +416,9 @@ D50 + + + None<br> p @@ -398,6 +436,9 @@ D50 + + + Polarising filter<br> 6 @@ -415,6 +456,9 @@ D50 + + + D65<br> u @@ -432,6 +476,9 @@ D50 + + + U.V. Cut<br> <a href="#E">-E extrafilterfile</a> Apply extra filter compensation file<br> @@ -452,6 +499,9 @@ D50 + + + Display Yxy instead of Lab<br> </span></font><font size="-1"><span style="font-family: monospace;"> <a href="#h">-h</a> @@ -470,6 +520,9 @@ D50 + + + Display LCh instead of Lab</span></font><br> <font size="-1"><span style="font-family: monospace;"> <a href="#V">-V</a> @@ -488,6 +541,9 @@ D50 + + + Show running average and std. devation from ref.</span></font><br> <font size="-1"><span style="font-family: monospace;"> <a href="#T">-T</a> @@ -506,6 +562,9 @@ D50 + + + Display correlated color temperatures and CRI<br> </span></font><font size="-1"><span style="font-family: monospace;"> <a href="#N">-N</a> @@ -523,6 +582,9 @@ D50 + + + Disable initial calibration of instrument if possible</span></font><br> <font size="-1"><span style="font-family: monospace;"> </span><a style="font-family: monospace;" href="#H">-H</a><span @@ -546,6 +608,9 @@ D50 + + + Apply Colorimeter Correction Matrix</span></font><br> <span style="font-family: monospace;"> <a href="#X2">-X file.ccss</a> @@ -568,6 +633,9 @@ Samples + + + for calibration</span><br> <font size="-1"><span style="font-family: monospace;"> </span><a style=" font-family: monospace;" href="#Yrn">-<font size="-1">Y</font> @@ -579,14 +647,20 @@ Samples + + + Override refresh, non-refresh display mode</span></font><br> + <tt> <a href="#YR">-Y R:<i>rate</i></a> + + Override measured refresh rate with rate Hz</tt><br> <font size="-1"><span style="font-family: monospace;"> </span><a - style=" font-family: monospace;" href="#YA">-<font size="-1">Y</font>A</a><span + style=" font-family: monospace;" href="#YA">-<font size="-1">Y </font>A</a><span style="font-family: monospace;"> - Use non-adaptive integration time mode - (if available).</span></font><br> + Use non-adaptive integration time mode (if + available).</span></font><br> <font size="-1"><span style="font-family: monospace;"> <a href="#W">-W n|h|x</a> Override @@ -611,6 +685,9 @@ none, + + + h = HW, x = Xon/Xoff</span></font><br> <small><span style="font-family: monospace;"> </span><a style=" font-family: monospace;" href="#D">-D [level]</a><span @@ -633,6 +710,9 @@ none, + + + Optional file to save reading results<br style="font-family: monospace;"> </span></font><small><span style="font-family: monospace;"></span><span @@ -695,7 +775,9 @@ none, <a name="ew"></a>The <span style="font-weight: bold;">-ew</span> flag allows measuring in emissive mode using instruments that support this mode, with the reading being relative to the white - value read as the first reading.<br> + value read as the first reading using a Bradford chromatic adaption. + This matches the absolute <-> relative intent transformation + of Argyll ICC profiles.<br> <br> <a name="p"></a>The <span style="font-weight: bold;">-p</span> flag allows measuring in telephoto mode, using instruments that support @@ -714,7 +796,9 @@ none, <a name="pw"></a>The <span style="font-weight: bold;">-pw</span> flag allows measuring in telephoto mode using instruments that support this mode, with the reading being relative to the white - value read as the first reading.<br> + value read as the first reading using a Bradford chromatic adaption. + This matches the absolute <-> relative intent transformation + of Argyll ICC profiles.<br> <br> <a name="a"></a>The <span style="font-weight: bold;">-a</span> flag allows measuring in ambient illumination mode using instruments that @@ -749,9 +833,9 @@ none, and how this works, see <a href="instruments.html">Operation of particular instruments</a>. <b>3)</b> Any installed CCSS files (if applicable), or CCMX files. These files are typically created - using <a href="file:///D:/src/argyll/doc/ccxxmake.html">ccxxmake</a>, + using <a href="ccxxmake.html">ccxxmake</a>, and installed using <a - href="file:///D:/src/argyll/doc/oeminst.html">oeminst</a>. The + href="oeminst.html">oeminst</a>. The default and Base Calibration types will be indicated in the usage.<br> <br> <a name="I"></a>The <b>-I</b> parameter allows specifying a @@ -883,6 +967,9 @@ a + + + colorimeters accuracy for a particular type of display.<br> <br> <a name="Yrn"></a> The -<span style="font-weight: bold;">Y r </span>and @@ -892,6 +979,9 @@ a + + + <b>-Y n</b> options overrides the refresh display mode set by the <a href="#y">-y display type selection</a>, with <b>-Y</b><span style="font-weight: bold;"> r</span> forcing refresh display mode, @@ -899,6 +989,12 @@ a instruments support a display measurement refresh mode, or the ability to override the mode set by the display type selection.<br> <br> + <a name="YR"></a> The -<span style="font-weight: bold;">Y R:<i>rate</i></span><b></b> + options overrides calibration of the instrument refresh rate. This + may be useful if the instrument supports this function and the + refresh rate cannot be accurately calibrated from the display + itself.<br> + <br> <a name="YA"></a> The -<span style="font-weight: bold;">Y A</span> option uses a non-adaptive integration time emission measurement mode, if the instrument supports it, such as the Eye-One Pro or @@ -975,6 +1071,10 @@ a can be toggled on and off using the <span style="font-weight: bold;">h</span> key.<br> <br> + If the instrument supports a laser target (such as the JETI + specbos), then this can be toggled on & off using the <b>t</b> + key. It will automatically be turned off at each measurement.<br> + <br> If the instrument supports stored readings (ie. DTP20), then these can be ignored using the <span style="font-weight: bold;">n</span> key.<br> |