summaryrefslogtreecommitdiff
path: root/debian/colprof.1
diff options
context:
space:
mode:
Diffstat (limited to 'debian/colprof.1')
-rw-r--r--debian/colprof.1369
1 files changed, 0 insertions, 369 deletions
diff --git a/debian/colprof.1 b/debian/colprof.1
deleted file mode 100644
index 75e8564..0000000
--- a/debian/colprof.1
+++ /dev/null
@@ -1,369 +0,0 @@
-.\" DO NOT MODIFY THIS FILE! It was generated by help2man 1.43.3.
-.TH CREATE "1" "August 2013" "Create ICC profile, Version 1.5.1" "User Commands"
-.SH NAME
-Create \- Create ICC profile.
-.SH DESCRIPTION
-Create ICC profile, Version 1.5.1
-Author: Graeme W. Gill, licensed under the AGPL Version 3
-.IP
-Diagnostic: Unknown flag '\-'
-.PP
-usage: debian/tmp/usr/bin/colprof [\-options] inoutfile
-.TP
-\fB\-v\fR
-Verbose mode
-.HP
-\fB\-A\fR manufacturer Manufacturer description string
-.TP
-\fB\-M\fR model
-Model description string
-.TP
-\fB\-D\fR description
-Profile Description string (Default "inoutfile")
-.TP
-\fB\-C\fR copyright
-Copyright string
-.TP
-\fB\-Z\fR tmnb
-Attributes: Transparency, Matte, Negative, BlackAndWhite
-.TP
-\fB\-Z\fR prsa
-Default intent: Perceptual, Rel. Colorimetric, Saturation, Abs. Colorimetric
-.TP
-\fB\-q\fR lmhu
-Quality \- Low, Medium (def), High, Ultra
-.TP
-\fB\-b\fR [lmhun]
-Low quality B2A table \- or specific B2A quality or none for input device
-.TP
-\fB\-y\fR
-Verify A2B profile
-.TP
-\fB\-ni\fR
-Don't create input (Device) shaper curves
-.TP
-\fB\-np\fR
-Don't create input (Device) grid position curves
-.TP
-\fB\-no\fR
-Don't create output (PCS) shaper curves
-.TP
-\fB\-nc\fR
-Don't put the input .ti3 data in the profile
-.TP
-\fB\-k\fR zhxr
-Black value target: z = zero K,
-h = 0.5 K, x = max K, r = ramp K (def.)
-.HP
-\fB\-k\fR p stle stpo enpo enle shape
-.IP
-stle: K level at White 0.0 \- 1.0
-stpo: start point of transition Wh 0.0 \- Bk 1.0
-enpo: End point of transition Wh 0.0 \- Bk 1.0
-enle: K level at Black 0.0 \- 1.0
-shape: 1.0 = straight, 0.0\-1.0 concave, 1.0\-2.0 convex
-.TP
-\fB\-K\fR parameters
-Same as \fB\-k\fR, but target is K locus rather than K value itself
-.TP
-\fB\-l\fR tlimit
-override total ink limit, 0 \- 400% (default from .ti3)
-.TP
-\fB\-L\fR klimit
-override black ink limit, 0 \- 100% (default from .ti3)
-.TP
-\fB\-a\fR lxXgsmGS
-Algorithm type override
-l = Lab cLUT (def.), x = XYZ cLUT, X = display XYZ cLUT + matrix
-g = gamma+matrix, s = shaper+matrix, m = matrix only,
-G = single gamma+matrix, S = single shaper+matrix
-.TP
-\fB\-u\fR
-If input profile, auto scale WP to allow extrapolation
-.TP
-\fB\-uc\fR
-If input profile, clip cLUT values above WP
-.TP
-\fB\-U\fR scale
-If input profile, scale media white point by scale
-.TP
-\fB\-R\fR
-Restrict white <= 1.0, black and primaries to be +ve
-.TP
-\fB\-f\fR [illum]
-Use Fluorescent Whitening Agent compensation [opt. simulated inst. illum.:
-.IP
-M0, M1, M2, A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp]
-.TP
-\fB\-i\fR illum
-Choose illuminant for computation of CIE XYZ from spectral data & FWA:
-.IP
-A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp
-.TP
-\fB\-o\fR observ
-Choose CIE Observer for spectral data:
-.IP
-1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2
-.TP
-\fB\-r\fR avgdev
-Average deviation of device+instrument readings as a percentage (default 0.50%)
-.TP
-\fB\-s\fR src.icc
-Apply gamut mapping to output profile perceptual B2A table for given source space
-.TP
-\fB\-S\fR src.icc
-Apply gamut mapping to output profile perceptual and saturation B2A table
-.TP
-\fB\-nP\fR
-Use colormetric source gamut to make output profile perceptual table
-.TP
-\fB\-nS\fR
-Use colormetric source gamut to make output profile saturation table
-.TP
-\fB\-g\fR src.gam
-Use source image gamut as well for output profile gamut mapping
-.TP
-\fB\-p\fR absprof,...
-Incorporate abstract profile(s) into output tables
-.TP
-\fB\-t\fR intent
-Override gamut mapping intent for output profile perceptual table:
-.TP
-\fB\-T\fR intent
-Override gamut mapping intent for output profile saturation table:
-.IP
-a \- Absolute Colorimetric (in Jab) [ICC Absolute Colorimetric]
-.IP
-aw \- Absolute Colorimetric (in Jab) with scaling to fit white point
-aa \- Absolute Appearance
-.IP
-r \- White Point Matched Appearance [ICC Relative Colorimetric]
-.IP
-la \- Luminance axis matched Appearance
-.IP
-p \- Perceptual (Preferred) (Default) [ICC Perceptual]
-.IP
-pa \- Perceptual Apperance
-ms \- Saturation
-.IP
-s \- Enhanced Saturation [ICC Saturation]
-.IP
-al \- Absolute Colorimetric (Lab)
-rl \- White Point Matched Appearance (Lab)
-.TP
-\fB\-c\fR viewcond
-set input viewing conditions for output profile CIECAM02 gamut mapping,
-.IP
-either an enumerated choice, or a parameter
-.TP
-\fB\-d\fR viewcond
-set output viewing conditions for output profile CIECAM02 gamut mapping
-.IP
-either an enumerated choice, or a parameter
-Also sets out of gamut clipping CAM space.
-either an enumerated choice, or a series of parameters:value changes
-.IP
-pp \- Practical Reflection Print (ISO\-3664 P2)
-pe \- Print evaluation environment (CIE 116\-1995)
-pc \- Critical print evaluation environment (ISO\-3664 P1)
-mt \- Monitor in typical work environment
-mb \- Bright monitor in bright work environment
-md \- Monitor in darkened work environment
-jm \- Projector in dim environment
-jd \- Projector in dark environment
-.IP
-pcd \- Photo CD \- original scene outdoors
-.IP
-ob \- Original scene \- Bright Outdoors
-cx \- Cut Sheet Transparencies on a viewing box
-.TP
-\fB\-P\fR
-Create gamut gammap_p.wrl and gammap_s.wrl diagostics
-.TP
-\fB\-O\fR outputfile
-Override the default output filename.
-.TP
-inoutfile
-Base name for input.ti3/output.icc file
-.PP
-Author: Graeme W. Gill, licensed under the AGPL Version 3
-.IP
-Diagnostic: Unknown flag '\-'
-.PP
-usage: debian/tmp/usr/bin/colprof [\-options] inoutfile
-.TP
-\fB\-v\fR
-Verbose mode
-.HP
-\fB\-A\fR manufacturer Manufacturer description string
-.TP
-\fB\-M\fR model
-Model description string
-.TP
-\fB\-D\fR description
-Profile Description string (Default "inoutfile")
-.TP
-\fB\-C\fR copyright
-Copyright string
-.TP
-\fB\-Z\fR tmnb
-Attributes: Transparency, Matte, Negative, BlackAndWhite
-.TP
-\fB\-Z\fR prsa
-Default intent: Perceptual, Rel. Colorimetric, Saturation, Abs. Colorimetric
-.TP
-\fB\-q\fR lmhu
-Quality \- Low, Medium (def), High, Ultra
-.TP
-\fB\-b\fR [lmhun]
-Low quality B2A table \- or specific B2A quality or none for input device
-.TP
-\fB\-y\fR
-Verify A2B profile
-.TP
-\fB\-ni\fR
-Don't create input (Device) shaper curves
-.TP
-\fB\-np\fR
-Don't create input (Device) grid position curves
-.TP
-\fB\-no\fR
-Don't create output (PCS) shaper curves
-.TP
-\fB\-nc\fR
-Don't put the input .ti3 data in the profile
-.TP
-\fB\-k\fR zhxr
-Black value target: z = zero K,
-h = 0.5 K, x = max K, r = ramp K (def.)
-.HP
-\fB\-k\fR p stle stpo enpo enle shape
-.IP
-stle: K level at White 0.0 \- 1.0
-stpo: start point of transition Wh 0.0 \- Bk 1.0
-enpo: End point of transition Wh 0.0 \- Bk 1.0
-enle: K level at Black 0.0 \- 1.0
-shape: 1.0 = straight, 0.0\-1.0 concave, 1.0\-2.0 convex
-.TP
-\fB\-K\fR parameters
-Same as \fB\-k\fR, but target is K locus rather than K value itself
-.TP
-\fB\-l\fR tlimit
-override total ink limit, 0 \- 400% (default from .ti3)
-.TP
-\fB\-L\fR klimit
-override black ink limit, 0 \- 100% (default from .ti3)
-.TP
-\fB\-a\fR lxXgsmGS
-Algorithm type override
-l = Lab cLUT (def.), x = XYZ cLUT, X = display XYZ cLUT + matrix
-g = gamma+matrix, s = shaper+matrix, m = matrix only,
-G = single gamma+matrix, S = single shaper+matrix
-.TP
-\fB\-u\fR
-If input profile, auto scale WP to allow extrapolation
-.TP
-\fB\-uc\fR
-If input profile, clip cLUT values above WP
-.TP
-\fB\-U\fR scale
-If input profile, scale media white point by scale
-.TP
-\fB\-R\fR
-Restrict white <= 1.0, black and primaries to be +ve
-.TP
-\fB\-f\fR [illum]
-Use Fluorescent Whitening Agent compensation [opt. simulated inst. illum.:
-.IP
-M0, M1, M2, A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp]
-.TP
-\fB\-i\fR illum
-Choose illuminant for computation of CIE XYZ from spectral data & FWA:
-.IP
-A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp
-.TP
-\fB\-o\fR observ
-Choose CIE Observer for spectral data:
-.IP
-1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2
-.TP
-\fB\-r\fR avgdev
-Average deviation of device+instrument readings as a percentage (default 0.50%)
-.TP
-\fB\-s\fR src.icc
-Apply gamut mapping to output profile perceptual B2A table for given source space
-.TP
-\fB\-S\fR src.icc
-Apply gamut mapping to output profile perceptual and saturation B2A table
-.TP
-\fB\-nP\fR
-Use colormetric source gamut to make output profile perceptual table
-.TP
-\fB\-nS\fR
-Use colormetric source gamut to make output profile saturation table
-.TP
-\fB\-g\fR src.gam
-Use source image gamut as well for output profile gamut mapping
-.TP
-\fB\-p\fR absprof,...
-Incorporate abstract profile(s) into output tables
-.TP
-\fB\-t\fR intent
-Override gamut mapping intent for output profile perceptual table:
-.TP
-\fB\-T\fR intent
-Override gamut mapping intent for output profile saturation table:
-.IP
-a \- Absolute Colorimetric (in Jab) [ICC Absolute Colorimetric]
-.IP
-aw \- Absolute Colorimetric (in Jab) with scaling to fit white point
-aa \- Absolute Appearance
-.IP
-r \- White Point Matched Appearance [ICC Relative Colorimetric]
-.IP
-la \- Luminance axis matched Appearance
-.IP
-p \- Perceptual (Preferred) (Default) [ICC Perceptual]
-.IP
-pa \- Perceptual Apperance
-ms \- Saturation
-.IP
-s \- Enhanced Saturation [ICC Saturation]
-.IP
-al \- Absolute Colorimetric (Lab)
-rl \- White Point Matched Appearance (Lab)
-.TP
-\fB\-c\fR viewcond
-set input viewing conditions for output profile CIECAM02 gamut mapping,
-.IP
-either an enumerated choice, or a parameter
-.TP
-\fB\-d\fR viewcond
-set output viewing conditions for output profile CIECAM02 gamut mapping
-.IP
-either an enumerated choice, or a parameter
-Also sets out of gamut clipping CAM space.
-either an enumerated choice, or a series of parameters:value changes
-.IP
-pp \- Practical Reflection Print (ISO\-3664 P2)
-pe \- Print evaluation environment (CIE 116\-1995)
-pc \- Critical print evaluation environment (ISO\-3664 P1)
-mt \- Monitor in typical work environment
-mb \- Bright monitor in bright work environment
-md \- Monitor in darkened work environment
-jm \- Projector in dim environment
-jd \- Projector in dark environment
-.IP
-pcd \- Photo CD \- original scene outdoors
-.IP
-ob \- Original scene \- Bright Outdoors
-cx \- Cut Sheet Transparencies on a viewing box
-.TP
-\fB\-P\fR
-Create gamut gammap_p.wrl and gammap_s.wrl diagostics
-.TP
-\fB\-O\fR outputfile
-Override the default output filename.
-.TP
-inoutfile
-Base name for input.ti3/output.icc file