summaryrefslogtreecommitdiff
path: root/debian/dispcal.1
diff options
context:
space:
mode:
Diffstat (limited to 'debian/dispcal.1')
-rw-r--r--debian/dispcal.1289
1 files changed, 0 insertions, 289 deletions
diff --git a/debian/dispcal.1 b/debian/dispcal.1
deleted file mode 100644
index ce04a1f..0000000
--- a/debian/dispcal.1
+++ /dev/null
@@ -1,289 +0,0 @@
-.\" DO NOT MODIFY THIS FILE! It was generated by help2man 1.43.3.
-.TH CALIBRATE "1" "August 2013" "Calibrate a Display, Version 1.5.1" "User Commands"
-.SH NAME
-Calibrate \- Calibrate a Display.
-.SH DESCRIPTION
-Calibrate a Display, Version 1.5.1
-Author: Graeme W. Gill, licensed under the AGPL Version 3
-Diagnostic: Usage requested
-usage: dispcal [options] outfile
-.TP
-\fB\-v\fR [n]
-Verbose mode
-.HP
-\fB\-display\fR displayname Choose X11 display name
-.TP
-\fB\-d\fR n[,m]
-Choose the display n from the following list (default 1)
-Optionally choose different display m for VideoLUT access
-.IP
-1 = 'Screen 1, Output VBOX0 at 0, 0, width 1605, height 1079'
-.TP
-\fB\-dweb[\fR:port]
-Display via a web server at port (default 8080)
-.TP
-\fB\-c\fR listno
-Set communication port from the following list (default 1)
-.IP
-** No ports found **
-.TP
-\fB\-r\fR
-Report on the calibrated display then exit
-.TP
-\fB\-R\fR
-Report on the uncalibrated display then exit
-.TP
-\fB\-m\fR
-Skip adjustment of the monitor controls
-.TP
-\fB\-o\fR [profile.icc]
-Create fast matrix/shaper profile [different filename to outfile.icc]
-.TP
-\fB\-O\fR "description"
-Fast ICC Profile Description string (Default "outfile")
-.TP
-\fB\-u\fR
-Update previous calibration and (if \fB\-o\fR used) ICC profile VideoLUTs
-.TP
-\fB\-q\fR [vlmh]
-Quality \- Very Low, Low, Medium (def), High
-.TP
-\fB\-p\fR
-Use telephoto mode (ie. for a projector) (if available)
-.TP
-\fB\-t\fR [temp]
-White Daylight locus target, optional target temperaturee in deg. K (deflt.)
-.TP
-\fB\-T\fR [temp]
-White Black Body locus target, optional target temperaturee in deg. K
-.TP
-\fB\-w\fR x,y
-Set the target white point as chromaticity coordinates
-.TP
-\fB\-b\fR bright
-Set the target white brightness in cd/m^2
-.TP
-\fB\-g\fR gamma
-Set the target response curve advertised gamma (Def. 2.4)
-Use "\-gl" for L*a*b* curve
-Use "\-gs" for sRGB curve
-Use "\-g709" for REC 709 curve (should use \fB\-a\fR as well!)
-Use "\-g240" for SMPTE 240M curve (should use \fB\-a\fR as well!)
-Use "\-G2.4 \fB\-f0\fR" for BT.1886
-.TP
-\fB\-G\fR gamma
-Set the target response curve actual technical gamma
-.TP
-\fB\-f\fR [degree]
-Amount of black level accounted for with output offset (default all output offset)
-.TP
-\fB\-a\fR ambient
-Use viewing condition adjustment for ambient in Lux
-.TP
-\fB\-k\fR factor
-Amount to correct black hue, 0 = none, 1 = full, Default = Automatic
-.TP
-\fB\-A\fR rate
-Rate of blending from neutral to black point. Default 4.0
-.TP
-\fB\-B\fR blkbright
-Set the target black brightness in cd/m^2
-.TP
-\fB\-e\fR [n]
-Run n verify passes on final curves
-.TP
-\fB\-E\fR
-Run only verify pass on installed calibration curves
-.TP
-\fB\-P\fR ho,vo,ss[,vs]
-Position test window and scale it
-ho,vi: 0.0 = left/top, 0.5 = center, 1.0 = right/bottom etc.
-ss: 0.5 = half, 1.0 = normal, 2.0 = double etc.
-.TP
-\fB\-F\fR
-Fill whole screen with black background
-.TP
-\fB\-n\fR
-Don't set override redirect on test window
-.TP
-\fB\-J\fR
-Run instrument calibration first (used rarely)
-.TP
-\fB\-N\fR
-Disable initial calibration of instrument if possible
-.TP
-\fB\-H\fR
-Use high resolution spectrum mode (if available)
-.TP
-\fB\-X\fR file.ccmx
-Apply Colorimeter Correction Matrix
-.TP
-\fB\-X\fR file.ccss
-Use Colorimeter Calibration Spectral Samples for calibration
-.TP
-\fB\-Q\fR observ
-Choose CIE Observer for spectrometer or CCSS colorimeter data:
-1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2, 1964_10c
-.TP
-\fB\-I\fR b|w
-Drift compensation, Black: \fB\-Ib\fR, White: \fB\-Iw\fR, Both: \fB\-Ibw\fR
-.TP
-\fB\-Y\fR A
-Use non\-adaptive integration time mode (if available).
-.TP
-\fB\-C\fR "command"
-Invoke shell "command" each time a color is set
-.TP
-\fB\-M\fR "command"
-Invoke shell "command" each time a color is measured
-.TP
-\fB\-W\fR n|h|x
-Override serial port flow control: n = none, h = HW, x = Xon/Xoff
-.TP
-\fB\-D\fR [level]
-Print debug diagnostics to stderr
-.TP
-inoutfile
-Base name for created or updated .cal and .icc output files
-.PP
-Author: Graeme W. Gill, licensed under the AGPL Version 3
-Diagnostic: Usage requested
-usage: dispcal [options] outfile
-.TP
-\fB\-v\fR [n]
-Verbose mode
-.HP
-\fB\-display\fR displayname Choose X11 display name
-.TP
-\fB\-d\fR n[,m]
-Choose the display n from the following list (default 1)
-Optionally choose different display m for VideoLUT access
-.IP
-1 = 'Screen 1, Output VBOX0 at 0, 0, width 1605, height 1079'
-.TP
-\fB\-dweb[\fR:port]
-Display via a web server at port (default 8080)
-.TP
-\fB\-c\fR listno
-Set communication port from the following list (default 1)
-.IP
-** No ports found **
-.TP
-\fB\-r\fR
-Report on the calibrated display then exit
-.TP
-\fB\-R\fR
-Report on the uncalibrated display then exit
-.TP
-\fB\-m\fR
-Skip adjustment of the monitor controls
-.TP
-\fB\-o\fR [profile.icc]
-Create fast matrix/shaper profile [different filename to outfile.icc]
-.TP
-\fB\-O\fR "description"
-Fast ICC Profile Description string (Default "outfile")
-.TP
-\fB\-u\fR
-Update previous calibration and (if \fB\-o\fR used) ICC profile VideoLUTs
-.TP
-\fB\-q\fR [vlmh]
-Quality \- Very Low, Low, Medium (def), High
-.TP
-\fB\-p\fR
-Use telephoto mode (ie. for a projector) (if available)
-.TP
-\fB\-t\fR [temp]
-White Daylight locus target, optional target temperaturee in deg. K (deflt.)
-.TP
-\fB\-T\fR [temp]
-White Black Body locus target, optional target temperaturee in deg. K
-.TP
-\fB\-w\fR x,y
-Set the target white point as chromaticity coordinates
-.TP
-\fB\-b\fR bright
-Set the target white brightness in cd/m^2
-.TP
-\fB\-g\fR gamma
-Set the target response curve advertised gamma (Def. 2.4)
-Use "\-gl" for L*a*b* curve
-Use "\-gs" for sRGB curve
-Use "\-g709" for REC 709 curve (should use \fB\-a\fR as well!)
-Use "\-g240" for SMPTE 240M curve (should use \fB\-a\fR as well!)
-Use "\-G2.4 \fB\-f0\fR" for BT.1886
-.TP
-\fB\-G\fR gamma
-Set the target response curve actual technical gamma
-.TP
-\fB\-f\fR [degree]
-Amount of black level accounted for with output offset (default all output offset)
-.TP
-\fB\-a\fR ambient
-Use viewing condition adjustment for ambient in Lux
-.TP
-\fB\-k\fR factor
-Amount to correct black hue, 0 = none, 1 = full, Default = Automatic
-.TP
-\fB\-A\fR rate
-Rate of blending from neutral to black point. Default 4.0
-.TP
-\fB\-B\fR blkbright
-Set the target black brightness in cd/m^2
-.TP
-\fB\-e\fR [n]
-Run n verify passes on final curves
-.TP
-\fB\-E\fR
-Run only verify pass on installed calibration curves
-.TP
-\fB\-P\fR ho,vo,ss[,vs]
-Position test window and scale it
-ho,vi: 0.0 = left/top, 0.5 = center, 1.0 = right/bottom etc.
-ss: 0.5 = half, 1.0 = normal, 2.0 = double etc.
-.TP
-\fB\-F\fR
-Fill whole screen with black background
-.TP
-\fB\-n\fR
-Don't set override redirect on test window
-.TP
-\fB\-J\fR
-Run instrument calibration first (used rarely)
-.TP
-\fB\-N\fR
-Disable initial calibration of instrument if possible
-.TP
-\fB\-H\fR
-Use high resolution spectrum mode (if available)
-.TP
-\fB\-X\fR file.ccmx
-Apply Colorimeter Correction Matrix
-.TP
-\fB\-X\fR file.ccss
-Use Colorimeter Calibration Spectral Samples for calibration
-.TP
-\fB\-Q\fR observ
-Choose CIE Observer for spectrometer or CCSS colorimeter data:
-1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2, 1964_10c
-.TP
-\fB\-I\fR b|w
-Drift compensation, Black: \fB\-Ib\fR, White: \fB\-Iw\fR, Both: \fB\-Ibw\fR
-.TP
-\fB\-Y\fR A
-Use non\-adaptive integration time mode (if available).
-.TP
-\fB\-C\fR "command"
-Invoke shell "command" each time a color is set
-.TP
-\fB\-M\fR "command"
-Invoke shell "command" each time a color is measured
-.TP
-\fB\-W\fR n|h|x
-Override serial port flow control: n = none, h = HW, x = Xon/Xoff
-.TP
-\fB\-D\fR [level]
-Print debug diagnostics to stderr
-.TP
-inoutfile
-Base name for created or updated .cal and .icc output files