summaryrefslogtreecommitdiff
path: root/debian/man/colprof.1
diff options
context:
space:
mode:
Diffstat (limited to 'debian/man/colprof.1')
-rw-r--r--debian/man/colprof.1371
1 files changed, 371 insertions, 0 deletions
diff --git a/debian/man/colprof.1 b/debian/man/colprof.1
new file mode 100644
index 0000000..b9feb69
--- /dev/null
+++ b/debian/man/colprof.1
@@ -0,0 +1,371 @@
+.\" DO NOT MODIFY THIS FILE! It was generated by help2man 1.44.1.
+.TH CREATE "1" "September 2014" "Create ICC profile, Version 1.6.3" "User Commands"
+.SH NAME
+Create \- Create ICC profile.
+.SH DESCRIPTION
+Create ICC profile, Version 1.6.3
+Author: Graeme W. Gill, licensed under the AGPL Version 3
+.IP
+Diagnostic: Unknown flag '\-'
+.PP
+usage: debian/tmp/usr/bin/colprof [\-options] inoutfile
+.TP
+\fB\-v\fR
+Verbose mode
+.HP
+\fB\-A\fR manufacturer Manufacturer description string
+.TP
+\fB\-M\fR model
+Model description string
+.TP
+\fB\-D\fR description
+Profile Description string (Default "inoutfile")
+.TP
+\fB\-C\fR copyright
+Copyright string
+.TP
+\fB\-Z\fR tmnb
+Attributes: Transparency, Matte, Negative, BlackAndWhite
+.TP
+\fB\-Z\fR prsa
+Default intent: Perceptual, Rel. Colorimetric, Saturation, Abs. Colorimetric
+.TP
+\fB\-q\fR lmhu
+Quality \- Low, Medium (def), High, Ultra
+.TP
+\fB\-b\fR [lmhun]
+Low quality B2A table \- or specific B2A quality or none for input device
+.TP
+\fB\-ni\fR
+Don't create input (Device) shaper curves
+.TP
+\fB\-np\fR
+Don't create input (Device) grid position curves
+.TP
+\fB\-no\fR
+Don't create output (PCS) shaper curves
+.TP
+\fB\-nc\fR
+Don't put the input .ti3 data in the profile
+.TP
+\fB\-k\fR zhxr
+Black value target: z = zero K,
+h = 0.5 K, x = max K, r = ramp K (def.)
+.HP
+\fB\-k\fR p stle stpo enpo enle shape
+.IP
+stle: K level at White 0.0 \- 1.0
+stpo: start point of transition Wh 0.0 \- Bk 1.0
+enpo: End point of transition Wh 0.0 \- Bk 1.0
+enle: K level at Black 0.0 \- 1.0
+shape: 1.0 = straight, 0.0\-1.0 concave, 1.0\-2.0 convex
+.TP
+\fB\-K\fR parameters
+Same as \fB\-k\fR, but target is K locus rather than K value itself
+.TP
+\fB\-l\fR tlimit
+override total ink limit, 0 \- 400% (default from .ti3)
+.TP
+\fB\-L\fR klimit
+override black ink limit, 0 \- 100% (default from .ti3)
+.TP
+\fB\-a\fR lxXgsmGS
+Algorithm type override
+l = Lab cLUT (def.), x = XYZ cLUT, X = display XYZ cLUT + matrix
+g = gamma+matrix, s = shaper+matrix, m = matrix only,
+G = single gamma+matrix, S = single shaper+matrix
+.TP
+\fB\-u\fR
+If input profile, auto scale WP to allow extrapolation
+.TP
+\fB\-uc\fR
+If input profile, clip cLUT values above WP
+.TP
+\fB\-U\fR scale
+If input profile, scale media white point by scale
+.TP
+\fB\-R\fR
+Restrict white <= 1.0, black and primaries to be +ve
+.TP
+\fB\-V\fR demphasis
+Degree of dark region cLUT grid emphasis 1.0\-4.0 (default 1.00 = none)
+.TP
+\fB\-f\fR [illum]
+Use Fluorescent Whitening Agent compensation [opt. simulated inst. illum.:
+.IP
+M0, M1, M2, A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp]
+.TP
+\fB\-i\fR illum
+Choose illuminant for computation of CIE XYZ from spectral data & FWA:
+.IP
+A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp
+.TP
+\fB\-o\fR observ
+Choose CIE Observer for spectral data:
+.IP
+1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2
+.TP
+\fB\-r\fR avgdev
+Average deviation of device+instrument readings as a percentage (default 0.50%)
+.TP
+\fB\-s\fR src.icc
+Apply gamut mapping to output profile perceptual B2A table for given source space
+.TP
+\fB\-S\fR src.icc
+Apply gamut mapping to output profile perceptual and saturation B2A table
+.TP
+\fB\-nP\fR
+Use colormetric source gamut to make output profile perceptual table
+.TP
+\fB\-nS\fR
+Use colormetric source gamut to make output profile saturation table
+.TP
+\fB\-g\fR src.gam
+Use source image gamut as well for output profile gamut mapping
+.TP
+\fB\-p\fR absprof,...
+Incorporate abstract profile(s) into output tables
+.TP
+\fB\-t\fR intent
+Override gamut mapping intent for output profile perceptual table:
+.TP
+\fB\-T\fR intent
+Override gamut mapping intent for output profile saturation table:
+.IP
+a \- Absolute Colorimetric (in Jab) [ICC Absolute Colorimetric]
+.IP
+aw \- Absolute Colorimetric (in Jab) with scaling to fit white point
+aa \- Absolute Appearance
+.IP
+r \- White Point Matched Appearance [ICC Relative Colorimetric]
+.IP
+la \- Luminance axis matched Appearance
+.IP
+p \- Perceptual (Preferred) (Default) [ICC Perceptual]
+.IP
+pa \- Perceptual Apperance
+ms \- Saturation
+.IP
+s \- Enhanced Saturation [ICC Saturation]
+.IP
+al \- Absolute Colorimetric (Lab)
+rl \- White Point Matched Colorimetric (Lab)
+.TP
+\fB\-c\fR viewcond
+set input viewing conditions for output profile CIECAM02 gamut mapping,
+.IP
+either an enumerated choice, or a parameter
+.TP
+\fB\-d\fR viewcond
+set output viewing conditions for output profile CIECAM02 gamut mapping
+.IP
+either an enumerated choice, or a parameter
+Also sets out of gamut clipping CAM space.
+either an enumerated choice, or a series of parameters:value changes
+.IP
+pp \- Practical Reflection Print (ISO\-3664 P2)
+pe \- Print evaluation environment (CIE 116\-1995)
+pc \- Critical print evaluation environment (ISO\-3664 P1)
+mt \- Monitor in typical work environment
+mb \- Bright monitor in bright work environment
+md \- Monitor in darkened work environment
+jm \- Projector in dim environment
+jd \- Projector in dark environment
+tv \- Television/Film Studio
+.IP
+pcd \- Photo CD \- original scene outdoors
+.IP
+ob \- Original scene \- Bright Outdoors
+cx \- Cut Sheet Transparencies on a viewing box
+.TP
+\fB\-P\fR
+Create gamut gammap_p.wrl and gammap_s.wrl diagostics
+.TP
+\fB\-O\fR outputfile
+Override the default output filename.
+.TP
+inoutfile
+Base name for input.ti3/output.icc file
+.PP
+Author: Graeme W. Gill, licensed under the AGPL Version 3
+.IP
+Diagnostic: Unknown flag '\-'
+.PP
+usage: debian/tmp/usr/bin/colprof [\-options] inoutfile
+.TP
+\fB\-v\fR
+Verbose mode
+.HP
+\fB\-A\fR manufacturer Manufacturer description string
+.TP
+\fB\-M\fR model
+Model description string
+.TP
+\fB\-D\fR description
+Profile Description string (Default "inoutfile")
+.TP
+\fB\-C\fR copyright
+Copyright string
+.TP
+\fB\-Z\fR tmnb
+Attributes: Transparency, Matte, Negative, BlackAndWhite
+.TP
+\fB\-Z\fR prsa
+Default intent: Perceptual, Rel. Colorimetric, Saturation, Abs. Colorimetric
+.TP
+\fB\-q\fR lmhu
+Quality \- Low, Medium (def), High, Ultra
+.TP
+\fB\-b\fR [lmhun]
+Low quality B2A table \- or specific B2A quality or none for input device
+.TP
+\fB\-ni\fR
+Don't create input (Device) shaper curves
+.TP
+\fB\-np\fR
+Don't create input (Device) grid position curves
+.TP
+\fB\-no\fR
+Don't create output (PCS) shaper curves
+.TP
+\fB\-nc\fR
+Don't put the input .ti3 data in the profile
+.TP
+\fB\-k\fR zhxr
+Black value target: z = zero K,
+h = 0.5 K, x = max K, r = ramp K (def.)
+.HP
+\fB\-k\fR p stle stpo enpo enle shape
+.IP
+stle: K level at White 0.0 \- 1.0
+stpo: start point of transition Wh 0.0 \- Bk 1.0
+enpo: End point of transition Wh 0.0 \- Bk 1.0
+enle: K level at Black 0.0 \- 1.0
+shape: 1.0 = straight, 0.0\-1.0 concave, 1.0\-2.0 convex
+.TP
+\fB\-K\fR parameters
+Same as \fB\-k\fR, but target is K locus rather than K value itself
+.TP
+\fB\-l\fR tlimit
+override total ink limit, 0 \- 400% (default from .ti3)
+.TP
+\fB\-L\fR klimit
+override black ink limit, 0 \- 100% (default from .ti3)
+.TP
+\fB\-a\fR lxXgsmGS
+Algorithm type override
+l = Lab cLUT (def.), x = XYZ cLUT, X = display XYZ cLUT + matrix
+g = gamma+matrix, s = shaper+matrix, m = matrix only,
+G = single gamma+matrix, S = single shaper+matrix
+.TP
+\fB\-u\fR
+If input profile, auto scale WP to allow extrapolation
+.TP
+\fB\-uc\fR
+If input profile, clip cLUT values above WP
+.TP
+\fB\-U\fR scale
+If input profile, scale media white point by scale
+.TP
+\fB\-R\fR
+Restrict white <= 1.0, black and primaries to be +ve
+.TP
+\fB\-V\fR demphasis
+Degree of dark region cLUT grid emphasis 1.0\-4.0 (default 1.00 = none)
+.TP
+\fB\-f\fR [illum]
+Use Fluorescent Whitening Agent compensation [opt. simulated inst. illum.:
+.IP
+M0, M1, M2, A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp]
+.TP
+\fB\-i\fR illum
+Choose illuminant for computation of CIE XYZ from spectral data & FWA:
+.IP
+A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp
+.TP
+\fB\-o\fR observ
+Choose CIE Observer for spectral data:
+.IP
+1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2
+.TP
+\fB\-r\fR avgdev
+Average deviation of device+instrument readings as a percentage (default 0.50%)
+.TP
+\fB\-s\fR src.icc
+Apply gamut mapping to output profile perceptual B2A table for given source space
+.TP
+\fB\-S\fR src.icc
+Apply gamut mapping to output profile perceptual and saturation B2A table
+.TP
+\fB\-nP\fR
+Use colormetric source gamut to make output profile perceptual table
+.TP
+\fB\-nS\fR
+Use colormetric source gamut to make output profile saturation table
+.TP
+\fB\-g\fR src.gam
+Use source image gamut as well for output profile gamut mapping
+.TP
+\fB\-p\fR absprof,...
+Incorporate abstract profile(s) into output tables
+.TP
+\fB\-t\fR intent
+Override gamut mapping intent for output profile perceptual table:
+.TP
+\fB\-T\fR intent
+Override gamut mapping intent for output profile saturation table:
+.IP
+a \- Absolute Colorimetric (in Jab) [ICC Absolute Colorimetric]
+.IP
+aw \- Absolute Colorimetric (in Jab) with scaling to fit white point
+aa \- Absolute Appearance
+.IP
+r \- White Point Matched Appearance [ICC Relative Colorimetric]
+.IP
+la \- Luminance axis matched Appearance
+.IP
+p \- Perceptual (Preferred) (Default) [ICC Perceptual]
+.IP
+pa \- Perceptual Apperance
+ms \- Saturation
+.IP
+s \- Enhanced Saturation [ICC Saturation]
+.IP
+al \- Absolute Colorimetric (Lab)
+rl \- White Point Matched Colorimetric (Lab)
+.TP
+\fB\-c\fR viewcond
+set input viewing conditions for output profile CIECAM02 gamut mapping,
+.IP
+either an enumerated choice, or a parameter
+.TP
+\fB\-d\fR viewcond
+set output viewing conditions for output profile CIECAM02 gamut mapping
+.IP
+either an enumerated choice, or a parameter
+Also sets out of gamut clipping CAM space.
+either an enumerated choice, or a series of parameters:value changes
+.IP
+pp \- Practical Reflection Print (ISO\-3664 P2)
+pe \- Print evaluation environment (CIE 116\-1995)
+pc \- Critical print evaluation environment (ISO\-3664 P1)
+mt \- Monitor in typical work environment
+mb \- Bright monitor in bright work environment
+md \- Monitor in darkened work environment
+jm \- Projector in dim environment
+jd \- Projector in dark environment
+tv \- Television/Film Studio
+.IP
+pcd \- Photo CD \- original scene outdoors
+.IP
+ob \- Original scene \- Bright Outdoors
+cx \- Cut Sheet Transparencies on a viewing box
+.TP
+\fB\-P\fR
+Create gamut gammap_p.wrl and gammap_s.wrl diagostics
+.TP
+\fB\-O\fR outputfile
+Override the default output filename.
+.TP
+inoutfile
+Base name for input.ti3/output.icc file