diff options
Diffstat (limited to 'debian/man/dispread.1')
-rw-r--r-- | debian/man/dispread.1 | 108 |
1 files changed, 5 insertions, 103 deletions
diff --git a/debian/man/dispread.1 b/debian/man/dispread.1 index dbf1776..a19b8c7 100644 --- a/debian/man/dispread.1 +++ b/debian/man/dispread.1 @@ -1,110 +1,12 @@ .\" DO NOT MODIFY THIS FILE! It was generated by help2man 1.44.1. -.TH READ "1" "September 2014" "Read a Display, Version 1.6.3" "User Commands" +.TH READ "1" "September 2014" "dispread" "User Commands" .SH NAME Read \- Read a Display. .SH DESCRIPTION -Read a Display, Version 1.6.3 -Author: Graeme W. Gill, licensed under the AGPL Version 3 -Diagnostic: Usage requested -usage: dispread [options] outfile -.TP -\fB\-v\fR -Verbose mode -.HP -\fB\-display\fR displayname Choose X11 display name -.TP -\fB\-d\fR n[,m] -Choose the display n from the following list (default 1) -Optionally choose different display m for VideoLUT access -.IP -1 = 'Screen 1, Output DVI\-I\-1 at 0, 0, width 1920, height 1080' -.TP -\fB\-dweb[\fR:port] -Display via a web server at port (default 8080) -.TP -\fB\-c\fR listno -Set communication port from the following list (default 1) -.IP -** No ports found ** -.TP -\fB\-p\fR -Use telephoto mode (ie. for a projector) (if available) -.TP -\fB\-k\fR file.cal -Load calibration file into display while reading -.TP -\fB\-K\fR file.cal -Apply calibration file to test values while reading -.TP -\fB\-s\fR -Save spectral information (default don't save) -.TP -\fB\-P\fR ho,vo,ss[,vs] -Position test window and scale it -ho,vi: 0.0 = left/top, 0.5 = center, 1.0 = right/bottom etc. -ss: 0.5 = half, 1.0 = normal, 2.0 = double etc. -.TP -\fB\-F\fR -Fill whole screen with black background -.TP -\fB\-n\fR -Don't set override redirect on test window -.TP -\fB\-E\fR -Encode the test values for video range 16..235/255 -.TP -\fB\-J\fR -Run instrument calibration first (used rarely) -.TP -\fB\-N\fR -Disable initial calibration of instrument if possible -.TP -\fB\-H\fR -Use high resolution spectrum mode (if available) -.TP -\fB\-w\fR -Disable normalisation of white to Y = 100 -.TP -\fB\-X\fR file.ccmx -Apply Colorimeter Correction Matrix -.TP -\fB\-X\fR file.ccss -Use Colorimeter Calibration Spectral Samples for calibration -.TP -\fB\-Q\fR observ -Choose CIE Observer for spectrometer or CCSS colorimeter data: -1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2, 1964_10c -.TP -\fB\-I\fR b|w -Drift compensation, Black: \fB\-Ib\fR, White: \fB\-Iw\fR, Both: \fB\-Ibw\fR -.TP -\fB\-Y\fR R:rate -Override measured refresh rate with rate Hz -.TP -\fB\-Y\fR A -Use non\-adaptive integration time mode (if available). -.TP -\fB\-Y\fR p -Don't wait for the instrument to be placed on the display -.TP -\fB\-C\fR "command" -Invoke shell "command" each time a color is set -.TP -\fB\-M\fR "command" -Invoke shell "command" each time a color is measured -.TP -\fB\-W\fR n|h|x -Override serial port flow control: n = none, h = HW, x = Xon/Xoff -.TP -\fB\-D\fR [level] -Print debug diagnostics to stderr -.TP -outfile -Base name for input[ti1]/output[ti3] file -.PP -Author: Graeme W. Gill, licensed under the AGPL Version 3 -Diagnostic: Usage requested -usage: dispread [options] outfile +Read a Display +.SH SYNOPSIS +.B dispread +.RB [options]\ outfile .TP \fB\-v\fR Verbose mode |