summaryrefslogtreecommitdiff
path: root/debian/man/dispread.1
diff options
context:
space:
mode:
Diffstat (limited to 'debian/man/dispread.1')
-rw-r--r--debian/man/dispread.1108
1 files changed, 5 insertions, 103 deletions
diff --git a/debian/man/dispread.1 b/debian/man/dispread.1
index dbf1776..a19b8c7 100644
--- a/debian/man/dispread.1
+++ b/debian/man/dispread.1
@@ -1,110 +1,12 @@
.\" DO NOT MODIFY THIS FILE! It was generated by help2man 1.44.1.
-.TH READ "1" "September 2014" "Read a Display, Version 1.6.3" "User Commands"
+.TH READ "1" "September 2014" "dispread" "User Commands"
.SH NAME
Read \- Read a Display.
.SH DESCRIPTION
-Read a Display, Version 1.6.3
-Author: Graeme W. Gill, licensed under the AGPL Version 3
-Diagnostic: Usage requested
-usage: dispread [options] outfile
-.TP
-\fB\-v\fR
-Verbose mode
-.HP
-\fB\-display\fR displayname Choose X11 display name
-.TP
-\fB\-d\fR n[,m]
-Choose the display n from the following list (default 1)
-Optionally choose different display m for VideoLUT access
-.IP
-1 = 'Screen 1, Output DVI\-I\-1 at 0, 0, width 1920, height 1080'
-.TP
-\fB\-dweb[\fR:port]
-Display via a web server at port (default 8080)
-.TP
-\fB\-c\fR listno
-Set communication port from the following list (default 1)
-.IP
-** No ports found **
-.TP
-\fB\-p\fR
-Use telephoto mode (ie. for a projector) (if available)
-.TP
-\fB\-k\fR file.cal
-Load calibration file into display while reading
-.TP
-\fB\-K\fR file.cal
-Apply calibration file to test values while reading
-.TP
-\fB\-s\fR
-Save spectral information (default don't save)
-.TP
-\fB\-P\fR ho,vo,ss[,vs]
-Position test window and scale it
-ho,vi: 0.0 = left/top, 0.5 = center, 1.0 = right/bottom etc.
-ss: 0.5 = half, 1.0 = normal, 2.0 = double etc.
-.TP
-\fB\-F\fR
-Fill whole screen with black background
-.TP
-\fB\-n\fR
-Don't set override redirect on test window
-.TP
-\fB\-E\fR
-Encode the test values for video range 16..235/255
-.TP
-\fB\-J\fR
-Run instrument calibration first (used rarely)
-.TP
-\fB\-N\fR
-Disable initial calibration of instrument if possible
-.TP
-\fB\-H\fR
-Use high resolution spectrum mode (if available)
-.TP
-\fB\-w\fR
-Disable normalisation of white to Y = 100
-.TP
-\fB\-X\fR file.ccmx
-Apply Colorimeter Correction Matrix
-.TP
-\fB\-X\fR file.ccss
-Use Colorimeter Calibration Spectral Samples for calibration
-.TP
-\fB\-Q\fR observ
-Choose CIE Observer for spectrometer or CCSS colorimeter data:
-1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2, 1964_10c
-.TP
-\fB\-I\fR b|w
-Drift compensation, Black: \fB\-Ib\fR, White: \fB\-Iw\fR, Both: \fB\-Ibw\fR
-.TP
-\fB\-Y\fR R:rate
-Override measured refresh rate with rate Hz
-.TP
-\fB\-Y\fR A
-Use non\-adaptive integration time mode (if available).
-.TP
-\fB\-Y\fR p
-Don't wait for the instrument to be placed on the display
-.TP
-\fB\-C\fR "command"
-Invoke shell "command" each time a color is set
-.TP
-\fB\-M\fR "command"
-Invoke shell "command" each time a color is measured
-.TP
-\fB\-W\fR n|h|x
-Override serial port flow control: n = none, h = HW, x = Xon/Xoff
-.TP
-\fB\-D\fR [level]
-Print debug diagnostics to stderr
-.TP
-outfile
-Base name for input[ti1]/output[ti3] file
-.PP
-Author: Graeme W. Gill, licensed under the AGPL Version 3
-Diagnostic: Usage requested
-usage: dispread [options] outfile
+Read a Display
+.SH SYNOPSIS
+.B dispread
+.RB [options]\ outfile
.TP
\fB\-v\fR
Verbose mode