+.\" DO NOT MODIFY THIS FILE! It was generated by help2man 1.44.1.
+.TH READ "1" "September 2014" "dispread" "User Commands"
+.SH NAME
+Read \- Read a Display.
+.SH DESCRIPTION
+Read a Display
+.SH SYNOPSIS
+.B dispread
+.RB [options]\ outfile
+.TP
+\fB\-v\fR
+Verbose mode
+.HP
+\fB\-display\fR displayname Choose X11 display name
+.TP
+\fB\-d\fR n[,m]
+Choose the display n from the following list (default 1)
+Optionally choose different display m for VideoLUT access
+.IP
+1 = 'Screen 1, Output DVI\-I\-1 at 0, 0, width 1920, height 1080'
+.TP
+\fB\-dweb[\fR:port]
+Display via a web server at port (default 8080)
+.TP
+\fB\-c\fR listno
+Set communication port from the following list (default 1)
+.IP
+** No ports found **
+.TP
+\fB\-p\fR
+Use telephoto mode (ie. for a projector) (if available)
+.TP
+\fB\-k\fR file.cal
+Load calibration file into display while reading
+.TP
+\fB\-K\fR file.cal
+Apply calibration file to test values while reading
+.TP
+\fB\-s\fR
+Save spectral information (default don't save)
+.TP
+\fB\-P\fR ho,vo,ss[,vs]
+Position test window and scale it
+ho,vi: 0.0 = left/top, 0.5 = center, 1.0 = right/bottom etc.
+ss: 0.5 = half, 1.0 = normal, 2.0 = double etc.
+.TP
+\fB\-F\fR
+Fill whole screen with black background
+.TP
+\fB\-n\fR
+Don't set override redirect on test window
+.TP
+\fB\-E\fR
+Encode the test values for video range 16..235/255
+.TP
+\fB\-J\fR
+Run instrument calibration first (used rarely)
+.TP
+\fB\-N\fR
+Disable initial calibration of instrument if possible
+.TP
+\fB\-H\fR
+Use high resolution spectrum mode (if available)
+.TP
+\fB\-w\fR
+Disable normalisation of white to Y = 100
+.TP
+\fB\-X\fR file.ccmx
+Apply Colorimeter Correction Matrix
+.TP
+\fB\-X\fR file.ccss
+Use Colorimeter Calibration Spectral Samples for calibration
+.TP
+\fB\-Q\fR observ
+Choose CIE Observer for spectrometer or CCSS colorimeter data:
+1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2, 1964_10c
+.TP
+\fB\-I\fR b|w
+Drift compensation, Black: \fB\-Ib\fR, White: \fB\-Iw\fR, Both: \fB\-Ibw\fR
+.TP
+\fB\-Y\fR R:rate
+Override measured refresh rate with rate Hz
+.TP
+\fB\-Y\fR A
+Use non\-adaptive integration time mode (if available).
+.TP
+\fB\-Y\fR p
+Don't wait for the instrument to be placed on the display
+.TP
+\fB\-C\fR "command"
+Invoke shell "command" each time a color is set
+.TP
+\fB\-M\fR "command"
+Invoke shell "command" each time a color is measured
+.TP
+\fB\-W\fR n|h|x
+Override serial port flow control: n = none, h = HW, x = Xon/Xoff
+.TP
+\fB\-D\fR [level]
+Print debug diagnostics to stderr
+.TP
+outfile
+Base name for input[ti1]/output[ti3] file