diff options
Diffstat (limited to 'debian/man/spotread.1')
-rw-r--r-- | debian/man/spotread.1 | 123 |
1 files changed, 123 insertions, 0 deletions
diff --git a/debian/man/spotread.1 b/debian/man/spotread.1 new file mode 100644 index 0000000..050f708 --- /dev/null +++ b/debian/man/spotread.1 @@ -0,0 +1,123 @@ +.\" DO NOT MODIFY THIS FILE! It was generated by help2man 1.44.1. +.TH MEASURE "1" "September 2014" "spotread" "User Commands" +.SH NAME +Measure \- Read Print Spot values. +.SH DESCRIPTION +Measure spot values, Version 1.6.3 +.SH SYNOPSIS +.B spotread +.RB [\-options]\ [logfile] +.TP +\fB\-v\fR +Verbose mode +.TP +\fB\-s\fR +Print spectrum for each reading +.TP +\fB\-S\fR +Plot spectrum for each reading +.TP +\fB\-c\fR listno +Set communication port from the following list (default 1) +.IP +** No ports found ** +.TP +\fB\-t\fR +Use transmission measurement mode +.TP +\fB\-e\fR +Use emissive measurement mode (absolute results) +.TP +\fB\-eb\fR +Use display white brightness relative measurement mode +.TP +\fB\-ew\fR +Use display white point relative chromatically adjusted mode +.TP +\fB\-p\fR +Use telephoto measurement mode (absolute results) +.TP +\fB\-pb\fR +Use projector white brightness relative measurement mode +.TP +\fB\-pw\fR +Use projector white point relative chromatically adjusted mode +.TP +\fB\-a\fR +Use ambient measurement mode (absolute results) +.TP +\fB\-f\fR +Use ambient flash measurement mode (absolute results) +.TP +\fB\-I\fR illum +Set simulated instrument illumination using FWA (def \fB\-i\fR illum): +M0, M1, M2, A, C, D50, D50M2, D65, F5, F8, F10 or file.sp] +.TP +\fB\-i\fR illum +Choose illuminant for computation of CIE XYZ from spectral data & FWA: +A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp +.TP +\fB\-Q\fR observ +Choose CIE Observer for spectral data or CCSS instrument: +1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2 +(Choose FWA during operation) +.TP +\fB\-F\fR filter +Set filter configuration (if aplicable): +.TP +n +None +.TP +p +Polarising filter +.TP +6 +D65 +.TP +u +U.V. Cut +.TP +\fB\-E\fR extrafilterfile +Apply extra filter compensation file +.TP +\fB\-x\fR +Display Yxy instead of Lab +.TP +\fB\-h\fR +Display LCh instead of Lab +.TP +\fB\-V\fR +Show running average and std. devation from ref. +.TP +\fB\-T\fR +Display correlated color temperatures and CRI +.TP +\fB\-N\fR +Disable auto calibration of instrument +.TP +\fB\-H\fR +Start in high resolution spectrum mode (if available) +.TP +\fB\-X\fR file.ccmx +Apply Colorimeter Correction Matrix +.TP +\fB\-X\fR file.ccss +Use Colorimeter Calibration Spectral Samples for calibration +.TP +\fB\-Y\fR r|n +Override refresh, non\-refresh display mode +.TP +\fB\-Y\fR R:rate +Override measured refresh rate with rate Hz +.TP +\fB\-Y\fR A +Use non\-adaptive integration time mode (if available). +.TP +\fB\-W\fR n|h|x +Override serial port flow control: n = none, h = HW, x = Xon/Xoff +.TP +\fB\-D\fR [level] +Print debug diagnostics to stderr +.TP +logfile +Optional file to save reading results as text |