+ <h2><b>spectro/</b><span style="text-decoration: underline;"></span>spec2cie</h2>
+ <h3>Summary</h3>
+ Convert spectral <a href="File_Formats.html#.ti3">.ti3</a>
+ readings into CIE XYZ or L*a*b* readings. FWA compensation may be
+ applied.<br>
+ <h3>Usage</h3>
+ <tt><small>spec2cie [options] <span style="font-style: italic;">input.ti3
+ output.ti3<br>
+ &nbsp;</span></small></tt><tt><small>-v
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
+ Verbose mode</small></tt><br>
+ <tt><small><small>&nbsp;<a
+ href="file:///D:/src/argyll/doc/spec2cie.html#I">-I <i>illum</i></a>&nbsp;&nbsp;
+ &nbsp;&nbsp; Override
+ actual instrument illuminant
+ in .ti3 file:<br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
+ &nbsp;
+ &nbsp;&nbsp; A, C, D50, D50M2, D65, F5,
+ F8, F10 or file.sp<br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
+ (only
+ used in conjunction with <span style="font-weight: bold;">-f</span>)<br>
+ </small></small></tt><tt><small><small>&nbsp;<a
+ href="file:///D:/src/argyll/doc/colprof.html#f">-f [<i>illum</i>]</a>
+ &nbsp;&nbsp; Use Fluorescent Whitening Agent compensation
+ [simulated inst. illum.:<br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
+ M0, M1, M2, A, C, D50 (def.), D50M2, D65, F5, F8, F10 or
+ file.sp]<br>
+ </small></small></tt><tt><small><small><small>&nbsp;<a
+ href="file:///D:/src/argyll/doc/spec2cie.html#i">-i <i>illum</i></a>&nbsp;&nbsp;
+ &nbsp;&nbsp; Choose illuminant for computation of CIE XYZ
+ from spectral data &amp; FWA:<br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
+ &nbsp;
+ &nbsp;&nbsp;&nbsp;
+ A, C, D50 (def.), D50M2, D65, F5,
+ F8, F10 or file.sp<br>
+ &nbsp;</small></small><a href="#o">-o
+ <i>observ</i></a>&nbsp;
+ &nbsp;&nbsp; Choose CIE Observer for spectral
+ data:<br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
+&nbsp;
+&nbsp;&nbsp;
+ 1931_2 </small></tt><tt><small> (def.)</small></tt><tt><small>,
+ 1964_10, S&amp;B
+ 1955_2, shaw, J&amp;V 1978_2<br>
+ &nbsp;<a href="#p">-n</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
+Don't
+output
+ spectral values<br>
+ </small></tt><tt><small>&nbsp;<a href="#p">-p</a>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
+ Plot
+ each values spectrum</small></tt><tt><br>
+ </tt><tt>
+ </tt><tt><small>&nbsp;<span style="font-style: italic;">input.ti3</span>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
+Measurement
+ file<br>
+ &nbsp;<span style="font-style: italic;">output.ti3</span>&nbsp;&nbsp;&nbsp;&nbsp;
+ Converted
+ measurement file</small></tt><br>
+ <h3>Comments</h3>
+ This program takes the spectral data in a .ti3 file, converts them
+ to
+ XYZ and Lab and fills the XYZ_[XYZ] and LAB_[LAB] columns in the
+ output
+ .ti3 file with the computed XYZ and Lab values. If the columns
+ XYZ_[XYZ] and/or LAB_[LAB] are missing in the input file, they are
+ added to the output file.<br>
+ <br>
+ All other columns are copied from the input to the output .ti3 file.<br>
+ <br>
+ <br>
+ <a name="I"></a>The <b>-I</b> parameter allows specifying a an
+ illumination
+ spectrum for the actual instrument illuminant, overriding that
+ computed from
+ the type of instrument (recorded in the .ti3 file). This is rarely
+ used. This parameter is can
+ only be used in combination with the <span style="font-weight:
+ bold;">-f</span>
+ flag. If a
+ filename is specified instead, it will be assumed to be an Argyll
+ specific <a href="file:///D:/src/argyll/doc/File_Formats.html#.sp">.sp</a>
+ custom spectrum file.
+ Illuminant details are:<br>
+ <br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; A&nbsp;&nbsp; CIE
+ tungsten
+ filament lamp 2848K<br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; D50 CIE daylight 5000K<br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; D65 CIE daylight 6500K<br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; F5&nbsp; CIE Fluorescent
+ 6350K, CRI 72<br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; F8&nbsp; CIE Fluorescent
+ 5000K, CRI 95<br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; F10 CIE Fluorescent
+ 5000K,
+ CRI 81<br>
+ <br>
+ <br>
+ <a name="f"></a> The <b>-f</b> flag enables Fluorescent Whitening
+ Agent (FWA) compensation. This only works if spectral data is
+ available and, the instrument is not UV filtered.&nbsp; FWA
+ compensation adjusts the spectral samples so that they appear to
+ have been measured using an illuminant that has a different level of
+ Ultra Violet to the one the instrument actually used in the
+ measurement. The optional illumination parameter allows specifying a
+ standard or custom illumination spectrum to be used as the similated
+ instrument illuminant, overriding the default <b>D50</b> or CIE
+ computation illuminant used for FWA (see <b>-i</b> below<b>). </b>See
+ <a href="colprof.html#f">colprof -f</a> for a fuller explanation. <br>
+ <br>
+ <a name="i"></a>The <b>-i</b> parameter allows specifying a
+ standard or custom illumination spectrum, applied to spectral .ti3
+ data to compute PCS (Profile Connection Space) tristimulus values. <b>A</b>,
+ <b>D50</b>, <b>D65</b>, <b>F5</b>, <b>F8</b>, <b>F10</b> are a
+ selection of standard illuminant spectrums, with <b>D50</b> being
+ the default. If a filename is specified instead, it will be assumed
+ to be an Argyll specific <a
+ href="file:///D:/src/argyll/doc/File_Formats.html#.sp">.sp</a>
+ custom spectrum file. This only works if spectral data is available.
+ Illuminant details are:<br>
+ <br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; A&nbsp;&nbsp; CIE
+ tungsten filament lamp 2848K<br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; D50 CIE daylight 5000K<br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; D65 CIE daylight 6500K<br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; F5&nbsp; CIE Fluorescent
+ 6350K, CRI 72<br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; F8&nbsp; CIE Fluorescent
+ 5000K, CRI 95<br>
+ &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; F10 CIE Fluorescent
+ 5000K, CRI 81<br>
+ <br>
+ Custom illuminants are most often used when a&nbsp; viewing booth or
+ other known viewing conditions is going to be used to view results.
+ Other illuminant reference files could be created using a suitable
+ measuring instrument such as a spectrolino, or an eyeone using <a
+ href="spotread.html">spotread</a>, although such instruments do
+ not themselves provide the necessary response down to Ultra Violet
+ that is needed for accurate operation of Fluorescent Whitening Agent
+ compensation. The best way of measuring a custom illuminant is to
+ use <a href="illumread.html">illumread</a>, since it uses a special
+ method to estimate the illuminant UV in a way that complements FWA
+ compensation. (See the discussion above for the <b>-f</b> flag).<br>
+ <br>
+ Note that if an illuminant other than D50 is chosen, the resulting
+ ICC profile will not be standard, and may not work perfectly with
+ other profiles that that use&nbsp; the standard ICC D50 illuminant,
+ particularly if the absolute rendering intent is used. Profiles
+ should generally be linked with other profiles that have the same
+ illuminant and observer.<br>
+ <br>
+ <a name="o"></a> The <b>-o</b> flag allows specifying a tristimulus
+ observer, and is used to compute PCS (Profile Connection Space)
+ tristimulus values. The following choices are available:<br>
+ <b>&nbsp; 1931_2</b> selects the standard CIE 1931 2 degree observer
+ (the default).<br>
+ &nbsp; <b>1964_10</b> selects the standard CIE 1964 10 degree
+ observer.<br>
+ &nbsp; <b>1955_2</b> selects the Stiles and Birch 1955 2 degree
+ observer<br>
+ &nbsp; <b>1978_2 </b>selects the Judd and Voss 1978 2 degree
+ observer<br>
+ &nbsp; <b>shaw</b> selects the Shaw and Fairchild 1997 2 degree
+ observer<br>
+ <br>
+ Note that if an observer other than 1931 2 degree is chosen, the
+ resulting ICC profile will not be standard, and cannot be freely
+ interchanged with other profiles that that us the standard 1931 2
+ degree
+ observer. Profiles should only be linked with other profiles that
+ have
+ the same illuminant and observer.<br>
+ <br>
+ <br>
+ <br>
+ <a name="n"></a>The <span style="font-weight: bold;">-n</span> flag
+ disables the output of the spectral values. If just the XYZ and
+ L*a*b*
+ values are needed, this makes for a smaller, easier to read file.<br>
+ <br>
+ <a name="p"></a>The <span style="font-weight: bold;">-p</span> flag
+ causes each spectrum to be plotted. If FWA compensation is used,
+ then
+ the before/after compensation spectrums will be shown.<br>