From c07d0c2d2f6f7b0eb6e92cc6204bf05037957e82 Mon Sep 17 00:00:00 2001 From: =?UTF-8?q?J=C3=B6rg=20Frings-F=C3=BCrst?= Date: Mon, 1 Sep 2014 15:43:52 +0200 Subject: Imported Upstream version 1.6.3 --- doc/Installing_MSWindows.html | 57 ++++++++++++++++++++----------------------- 1 file changed, 26 insertions(+), 31 deletions(-) (limited to 'doc/Installing_MSWindows.html') diff --git a/doc/Installing_MSWindows.html b/doc/Installing_MSWindows.html index 9079db0..c08e16d 100644 --- a/doc/Installing_MSWindows.html +++ b/doc/Installing_MSWindows.html @@ -2,9 +2,9 @@ + charset=windows-1252"> + charset=windows-1252"> Argyll Installation on Microsoft Windows @@ -60,9 +60,9 @@
 So if the current value of PATH is "%SystemRoot%\system32;%SystemRoot%" and you unpacked Argyll version - 1.5.1 in d:\bin\, then you + 1.6.3 in d:\bin\, then you would modify PATH to be - "%SystemRoot%\system32;%SystemRoot%;d:\bin\Argyll_V1.5.1\bin", - + "%SystemRoot%\system32;%SystemRoot%;d:\bin\Argyll_V1.6.3\bin", - i.e. you append the path to the Argyll binaries to your PATH, separated by the ';' character. The change will take effect when you start a new command shell, which you start from Start @@ -112,25 +112,31 @@ have to disable all of them. Reboot after changing settings.


-

Serial Instruments:
+

Serial Instruments:

If you are using a serial connected instrument, then there is nothing special to do to enable this.
-

USB Instruments:

+

USB Instruments:

If you are using a USB connected instrument, then suitable USB drivers may need to be - installed.
+ style="font-weight: bold;">USB system drivers may need to + be installed.

-
Note that the Huey - and i1 Display Pro and ColorMunki Display colorimeter - appears as an HID (USB Human Interface Device Class) device, and - hence will be assigned to the default MSWindows HID driver. You - therefore don't need to install an Argyll usb driver for these - instruments, although it is possible to select the libusb0.sys - driver as an alternative to the default HID driver.
+ Note that the Huey, + i1 Display Pro, ColorMunki Display and ColorHug + colorimeter appears as an HID (USB Human Interface Device Class) + device, and hence will be assigned to the default MSWindows HID + driver. You therefore don't need to install an + Argyll usb system driver + for these instruments, although it is possible to select the + libusb0.sys driver as an alternative to the default HID driver.
+
+ If you are using the JETI specbos 1211 or 1201, + then you may need to install the FTDI Virtual COM + Port Drivers (VCP), if they are not already on your system.

Jump to your operating system version:

@@ -158,13 +164,7 @@
To install the Argyll driver for the first instrument:
-     Settings -> Power -> Hold Shift Key down and click - "Restart" -> Troubleshoot -> Advanced Options -> Startup - Settings -> Restart ->
-     (After Reboot) -> "Disable Driver Signature - Enforcement" (number 7 on the list)
-     (After system starts, Plug in instrument)
+     (Plug in instrument)
    Desktop -> Settings -> Control Panel -> Hardware and Sound -> Device Manager ->
    Other Devices -> <instrument being @@ -191,12 +191,7 @@
To install the Argyll Driver:
- Settings -> Power -> Hold - Shift Key down and click "Restart" -> Troubleshoot -> - Advanced Options -> Startup Settings -> Restart ->
-     (After Reboot) -> Disable Driver Signature - Enforcement" (number 7 on the list)
-     (After system starts, Plug in instrument)
+     (Plug in instrument)
    Desktop -> Settings -> Control Panel -> Hardware and Sound -> Device Manager
    (Locate the instrument in the device list. It may -- cgit v1.2.3