From 9491825ddff7a294d1f49061bae7044e426aeb2e Mon Sep 17 00:00:00 2001 From: =?UTF-8?q?J=C3=B6rg=20Frings-F=C3=BCrst?= Date: Fri, 6 Nov 2015 05:38:49 +0100 Subject: Imported Upstream version 1.8.3 --- doc/chartread.html | 51 ++++++++++++++++++++++++++++++++++++++------------- 1 file changed, 38 insertions(+), 13 deletions(-) mode change 100644 => 100755 doc/chartread.html (limited to 'doc/chartread.html') diff --git a/doc/chartread.html b/doc/chartread.html old mode 100644 new mode 100755 index 4d5b005..e9dddaf --- a/doc/chartread.html +++ b/doc/chartread.html @@ -27,6 +27,7 @@ Verbose + mode
 -c listno  -d
@@ -62,6 +65,7 @@ measurement + Display type - instrument specific list to choose from.

 -e  -p
  -x [lx]            Take - manually entered - values, either L*a*b* (-xl) or XYZ (-xx).

 -n
 -l  -I file.cal        Override @@ -127,30 +135,35 @@ partly + Set filter configuration:
  n                  + None
  p                  + Polarising filter
  6                  + D65
  u                  + U.V. Cut

 
 
-X file.ccss          @@ -188,6 +202,7 @@ Samples + for calibration
 -Q observ1931_2 (def.)  -S                 @@ -224,6 +241,7 @@ strip + & unexpected value warnings
 -W n|h|x           @@ -231,6 +249,7 @@ Override + serial port flow control: n = none, h = HW, x = Xon/Xoff
.ti2]/output[chartread + -I parameter allows overriding the .ti2 calibration curves placed in the resulting .ti3 file with the actual calibration that was used for that particular print.
@@ -415,12 +436,15 @@ Override strip instruments (i.e.. Eye-One Pro, Color Munki) when used with Argyll will automatically recognize a strip when read in the reverse direction by matching the patch readings against their expected - values. If the randomized patch layout has not been used, or the - expected values are not known accurately enough, this may cause - erroneous reverse recognition, so the -B flag - allows this to be turned off, forcing strips to only be read in the - forward direction.
+ values. If the expected values are not known accurately enough, this + may cause erroneous reverse recognition, so the -B + flag allows this to be turned off, forcing strips to only be read in + the forward direction. (Note that the DTP20 always allows + bi-directional strip reading.) If the randomized patch layout has + not been used, then  bi-directional strip recognition will + automatically turned off, and a warning issued if the -B flag is not + used.

The -H option turns on high resolution spectral mode, if the instrument @@ -443,10 +467,8 @@ Override colorimeters that rely on sensor spectral sensitivity calibration information (ie. the X-Rite i1d3, or the DataColor Spyder4 & - Spyder 5).This - can - improve - a colorimeters accuracy for a particular type of display.
+ Spyder 5).This can improve a colorimeters accuracy for a + particular type of display.

The -T ratio argument modifies the patch consistency tolerance threshold for some @@ -482,7 +504,10 @@ Override advisable to also use the -B flag if warnings are turned off, since many warnings indicate that the expected values are not to be relied on. With warnings - suppressed, greater care must be taken to read the correct strip.
+ suppressed, greater care must be taken to read the correct strip. If + the randomized patch layout has not been used, then "wrong strip" + warnings will automatically be suppressed, and bi-directional strip + recognition turned off.

The -W n|h|x parameter overrides the default serial communications flow control -- cgit v1.2.3