1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
|
.\" DO NOT MODIFY THIS FILE! It was generated by help2man 1.43.3.
.TH READ "1" "August 2013" "Read Target Test Chart, Version 1.5.1" "User Commands"
.SH NAME
Read \- Read Target Test Chart.
.SH DESCRIPTION
Read Target Test Chart, Version 1.5.1
Author: Graeme W. Gill, licensed under the AGPL Version 3
usage: chartread [\-options] outfile
.TP
\fB\-v\fR
Verbose mode
.TP
\fB\-c\fR listno
Set communication port from the following list (default 1)
.IP
** No ports found **
.TP
\fB\-t\fR
Use transmission measurement mode
.TP
\fB\-d\fR
Use display measurement mode (white Y relative results)
.TP
\fB\-e\fR
Emissive for transparency on a light box
.TP
\fB\-p\fR
Measure patch by patch rather than strip
.TP
\fB\-x\fR [lx]
Take external values, either L*a*b* (\fB\-xl\fR) or XYZ (\fB\-xx\fR).
.TP
\fB\-n\fR
Don't save spectral information (default saves spectral)
.TP
\fB\-l\fR
Save CIE as D50 L*a*b* rather than XYZ
.TP
\fB\-L\fR
Save CIE as D50 L*a*b* as well as XYZ
.TP
\fB\-r\fR
Resume reading partly read chart
.TP
\fB\-I\fR file.cal
Override calibration info from .ti2 in resulting .ti3
.TP
\fB\-F\fR filter
Set filter configuration (if aplicable):
.TP
n
None
.TP
p
Polarising filter
.TP
6
D65
.TP
u
U.V. Cut
.TP
\fB\-N\fR
Disable initial calibration of instrument if possible
.TP
\fB\-B\fR
Disable auto bi\-directional strip recognition
.TP
\fB\-H\fR
Use high resolution spectrum mode (if available)
.TP
\fB\-X\fR file.ccmx
Apply Colorimeter Correction Matrix
.TP
\fB\-X\fR file.ccss
Use Colorimeter Calibration Spectral Samples for calibration
.TP
\fB\-Q\fR observ
Choose CIE Observer for CCSS instrument:
1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2
.TP
\fB\-T\fR ratio
Modify strip patch consistency tolerance by ratio
.TP
\fB\-S\fR
Suppress wrong strip & unexpected value warnings
.TP
\fB\-W\fR n|h|x
Override serial port flow control: n = none, h = HW, x = Xon/Xoff
.TP
\fB\-D\fR [level]
Print debug diagnostics to stderr
.TP
outfile
Base name for input[ti2]/output[ti3] file
.PP
Author: Graeme W. Gill, licensed under the AGPL Version 3
usage: chartread [\-options] outfile
.TP
\fB\-v\fR
Verbose mode
.TP
\fB\-c\fR listno
Set communication port from the following list (default 1)
.IP
** No ports found **
.TP
\fB\-t\fR
Use transmission measurement mode
.TP
\fB\-d\fR
Use display measurement mode (white Y relative results)
.TP
\fB\-e\fR
Emissive for transparency on a light box
.TP
\fB\-p\fR
Measure patch by patch rather than strip
.TP
\fB\-x\fR [lx]
Take external values, either L*a*b* (\fB\-xl\fR) or XYZ (\fB\-xx\fR).
.TP
\fB\-n\fR
Don't save spectral information (default saves spectral)
.TP
\fB\-l\fR
Save CIE as D50 L*a*b* rather than XYZ
.TP
\fB\-L\fR
Save CIE as D50 L*a*b* as well as XYZ
.TP
\fB\-r\fR
Resume reading partly read chart
.TP
\fB\-I\fR file.cal
Override calibration info from .ti2 in resulting .ti3
.TP
\fB\-F\fR filter
Set filter configuration (if aplicable):
.TP
n
None
.TP
p
Polarising filter
.TP
6
D65
.TP
u
U.V. Cut
.TP
\fB\-N\fR
Disable initial calibration of instrument if possible
.TP
\fB\-B\fR
Disable auto bi\-directional strip recognition
.TP
\fB\-H\fR
Use high resolution spectrum mode (if available)
.TP
\fB\-X\fR file.ccmx
Apply Colorimeter Correction Matrix
.TP
\fB\-X\fR file.ccss
Use Colorimeter Calibration Spectral Samples for calibration
.TP
\fB\-Q\fR observ
Choose CIE Observer for CCSS instrument:
1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2
.TP
\fB\-T\fR ratio
Modify strip patch consistency tolerance by ratio
.TP
\fB\-S\fR
Suppress wrong strip & unexpected value warnings
.TP
\fB\-W\fR n|h|x
Override serial port flow control: n = none, h = HW, x = Xon/Xoff
.TP
\fB\-D\fR [level]
Print debug diagnostics to stderr
.TP
outfile
Base name for input[ti2]/output[ti3] file
|