summaryrefslogtreecommitdiff
path: root/doc/XRGA.html
blob: 778b8bdc5d5692e27dac1e7d33b8ebf124e84af1 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
<!DOCTYPE html PUBLIC "-//w3c//dtd html 4.0 transitional//en">
<html>
  <head>
    <meta http-equiv="Content-Type" content="text/html;
      charset=windows-1252">
    <meta http-equiv="content-type" content="text/html;
      charset=windows-1252">
    <meta name="GENERATOR" content="Mozilla/4.73 [en] (WinNT; I)
      [Netscape]">
    <title>Argyll XRGA conversion</title>
  </head>
  <body>
    <br>
    <h2> <u>Conversion to/from XRGA<br>
      </u></h2>
    After purchasing Gretag-Macbeth, X-Rite harmonized the subtly
    different calibration standards the two companies were using for
    their reflective measurement instruments, in order to minimize
    changes with the introduction of new instruments. The result was the
    <a href="http://www.xrite.com/xrite-graphic-arts-standard">XRGA
      standard</a>, introduced in September 2010.<br>
    <br>
    Current X-Rite instruments are natively calibrated to XRGA, while
    older instruments from X-Rite are calibrated to XRDI, and
    Gretag-Macbeth instruments to GMDI standards. To smooth the
    interchange of old and new instruments, a spectral <a
href="https://www.xrite.com/documents/literature/en/L7-462_XRGA_WhitePaper_en.pdf">conversion



      is possible</a> between these different standards. While such a
    conversion is not perfect, it reduces the discontinuities between
    old instrument families and current X-Rite instruments.<br>
    <br>
    By default, Argyll will use the native calibration of Gretag-Macbeth
    and X-Rite instruments. These are summarized here:<br>
    <br>
    &nbsp; <br>
    <table border="0" cellpadding="2" cellspacing="2">
      <tbody>
        <tr>
          <td valign="top"><a href="instruments.html#DTP20">DTP20
              "Pulse"</a>&nbsp; <br>
          </td>
          <td valign="top">XRDI<br>
          </td>
        </tr>
        <tr>
          <td valign="top"><a href="instruments.html#DTP22">DTP22
              Digital Swatchbook</a></td>
          <td valign="top">XRDI<br>
          </td>
        </tr>
        <tr>
          <td valign="top"><a href="instruments.html#DTP41">DTP41</a></td>
          <td valign="top">XRDI<br>
          </td>
        </tr>
        <tr>
          <td valign="top"><a href="instruments.html#dtp51">DTP51</a></td>
          <td valign="top">XRDI<br>
          </td>
        </tr>
        <tr>
          <td valign="top"> <a href="instruments.html#sl">Spectrolino</a>/
            <a href="instruments.html#ss">SpectroScan</a></td>
          <td valign="top">GMDI<br>
          </td>
        </tr>
        <tr>
          <td valign="top"><a href="instruments.html#i1p">Eye-One Pro</a>
            Rev A-D</td>
          <td valign="top">GMDI<br>
          </td>
        </tr>
        <tr>
          <td valign="top"><a href="instruments.html#ColorMunki"><span
                style="text-decoration: underline;">ColorMunki</span></a>
            Design or Photo</td>
          <td valign="top">XRGA<br>
          </td>
        </tr>
        <tr>
          <td valign="top"><a href="instruments.html#i1p2">Eye-One Pro2</a>
            (Eye-One Pro Rev E)</td>
          <td valign="top">XRGA<br>
          </td>
        </tr>
      </tbody>
    </table>
    <br>
    <br>
    You can override this and force reflective data to be a particular
    calibration standard in two ways:<br>
    <br>
    <a name="A"></a>Using the <b>-A</b> command line option in <a
      href="spotread.html#A">spotread</a> and <a
      href="chartread.html#A">chartread</a>:<br>
    <br>
    &nbsp;&nbsp;&nbsp; <b>-A </b>N|A|X|G<br>
    <br>
    &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; The <b>N</b> argument sets
    the calibration to Native.<br>
    &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; The <b>A</b> argument sets
    the calibration to XRGA.<br>
    &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; The <b>X</b> argument sets
    the calibration to XRDI.<br>
    &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; The <b>G</b> argument sets
    the calibration to GMDI.<br>
    <br>
    <br>
    Or by setting an environment variable:<br>
    (Note that command line options will override this.)<br>
    <br>
    <br>
    <span style="font-weight: bold;"><a name="ARGYLL_XRGA"></a>ARGYLL_XRGA</span><br>
    <br>
    <div style="margin-left: 40px;"> If the <span style="font-weight:
        bold;">ARGYLL_XRGA&nbsp;</span> environment variable is set to:<br>
      <br>
      &nbsp;&nbsp;&nbsp; <b>XRGA</b>, then all Getag-MacBeth/X-Rite
      reflective measurements will be converted to XRGA.<br>
      <b>&nbsp;&nbsp;&nbsp; XRDI</b>, then all Getag-MacBeth/X-Rite
      reflective measurements will be converted to XRDI.<br>
      <b>&nbsp;&nbsp;&nbsp; GMDI</b>, then all Getag-MacBeth/X-Rite
      reflective measurements will be converted to GMDI.<br>
      <br>
      If not set (or set to some other string), then the native
      calibration will be used. Note that the values must be upper case.<br>
    </div>
    <span style="font-weight: bold;"></span><br>
    All of the above except the <b>DTP51</b> can have a conversion
    applied. <br>
    (The DTP51 returns only colorimetric data, while the conversion
    requires spectral data.)<br>
    <br>
    You can also convert from one standard to the other using <a
      href="spec2cie.html#A">spec2cie</a>.<br>
    <br>