summaryrefslogtreecommitdiff
path: root/doc/applycal.html
blob: 5c5e6616939b95173879fe27ddec8bcf56d28e2c (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<html>
  <head>
    <title>applycal</title>
    <meta http-equiv="content-type" content="text/html;
      charset=ISO-8859-1">
    <meta name="author" content="Graeme W. Gill">
  </head>
  <body>
    <h2><b>profile/applycal</b></h2>
    <h3>Summary</h3>
    Apply, re-apply or remove calibration curves to an ICC profile.<br>
    <h3>Usage Summary</h3>
    <small><span style="font-family: monospace;">usage: applycal
        [-options]
        [calfile.cal] inprof.icm [outprof.icm]<br>
        &nbsp;<a href="#v">-v</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Verbose
        mode<br>
        &nbsp;<a href="#a">-a</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Apply
        or re-apply calibration (default)<br>
        &nbsp;<a href="#u">-u</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Remove
        calibration<br>
        &nbsp;<a href="#c">-c</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Check
        calibration<br>
        &nbsp;<a href="#p1">calfile.cal</a>&nbsp;&nbsp;&nbsp;&nbsp;
        Calibration
        file to apply<br>
        &nbsp;<a href="#p2">inprof.icm</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
        ICC
        profile to read<br>
        &nbsp;<a href="#p3">outprof.icm</a>&nbsp;&nbsp;&nbsp;&nbsp;
        modified
        ICC
        profile to write</span></small><br>
    <br>
    <h3>Usage Details <br>
    </h3>
    <a name="v"></a> The <b>-v</b> flag makes applycal more verbose.<br>
    <br>
    <span style="font-weight: bold;"><a name="a"></a>-a</span> By
    default
    the <span style="font-weight: bold;">calfile.cal </span>is applied
    or
    re-applied to the <span style="font-weight: bold;">inprof.icm</span>,
    and then written to <span style="font-weight: bold;">outprof.icm</span>.<br>
    <br>
    <span style="font-weight: bold;"><a name="u"></a>-u</span> This flag
    causes any calibration applied to the <span style="font-weight:
      bold;">inprof.icm</span>
    to be remove, the profile being restored to its pre-calibrated
    state,
    and then written to <span style="font-weight: bold;">outprof.icm</span>.<br>
    <br>
    <span style="font-weight: bold;"><a name="c"></a>-c</span> This flag
    checks the <span style="font-weight: bold;">inprof.icm</span> and
    if
    verbose is on, reports whether it has had calibration applied. It
    will
    return status 0 if it has not been applied, 1 if it has, and 2 on
    error.<br>
    <br>
    <span style="font-weight: bold;"><a name="p1"></a>calfile.cal</span>&nbsp;
must
    be supplied if the calibration is being applied or re-applied.<br>
    <br>
    <span style="font-weight: bold;"><a name="p2"></a>inprof.icm</span>&nbsp;
should
    be the
    path to the ICC profile that will have calibration applied,
    re-applied
    or removed. The appropriate extension should be used for the
    platform, i.e. <span style="font-weight: bold;">icm</span> for
    MSWindows, and <span style="font-weight: bold;">icc</span> for OS X
    or
    Unix/Linux.<br>
    <br>
    <span style="font-weight: bold;"><a name="p3"></a>outprof.icm</span>&nbsp;
should
    be the
    path to the file that will be created to hold the modified ICC
    profile.
    The appropriate extension should be used for the
    platform, i.e. <span style="font-weight: bold;">icm</span> for
    MSWindows, and <span style="font-weight: bold;">icc</span> for OS X
    or
    Unix/Linux.<br>
    <br>
    <h3>Discussion</h3>
    <span style="font-weight: bold;">Applycal</span> provides a means of
    using per channel calibration on devices and systems that don't
    explicitly support such calibration. Once a calibration has been
    created for a device (see <a href="printcal.html">printcal</a>), it
    needs to be then used for all subsequent profiling and printing. If
    the
    printing device, display or system doesn't explicitly support the
    use of
    calibration, then the calibration can be applied during the printing
    of
    profile test charts using <a href="printtarg.html#K">printtarg -K</a>,
    or the reading of a display target using dispread -K, and then for
    processing imagery using <a href="cctiff.html">cctiff</a>
    or by modifying the device ICC profiles using <span
      style="font-weight: bold;">applycal</span>.<br>
    <br>
    <span style="font-weight: bold;">Applycal</span> modifies the
    appropriate input or output per-channel curves of the profile to
    incorporate the per-channel calibration. To allow the calibration to
    be
    re-applied or removed, it first makes a copy of the uncalibrated
    curves
    and stores them in private tags in the profile.<br>
    <br>
    <span style="font-weight: bold;">NOTE</span> that things like the
    white point, black point tag, gamut tag etc. are <span
      style="text-decoration: underline;">not</span> adjusted to account
    for the calibration, nor does applycal read, add or change any
    'vcgt' tag (If a 'vcgt' tag is present and a calibration applied as
    well, then both will be in effect when such a profile is installed
    using typical display installation tools.)<br>
    <br>
    <span style="font-weight: bold;">NOTE</span> that any calibration
    embedded in the ICC profile <span style="font-weight: bold;">'targ</span>'
    tag is ignored, since it is intended for computation of final
    calibrated device value ink limits, and may not represent the exact
    current calibration curves.<br>