summaryrefslogtreecommitdiff
path: root/doc/verify.html
blob: bd4a953439dd21725378a130c1d3c8cc35da5268 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<html>
  <head>
    <title>verify</title>
    <meta http-equiv="content-type" content="text/html;
      charset=ISO-8859-1">
    <meta name="author" content="Graeme Gill">
  </head>
  <body>
    <h2><b>profile/verify</b></h2>
    <h3>Summary</h3>
    Verify a color transform by comparing CIE measurement values from
    two test charts. The charts can be any suitably formatted CGATS or <a
      href="File_Formats.html#.ti3">.ti3</a> format that contains
    corresponding XYZ, Lab or spectral values. The overall average and
    worst case delta E will be reported, as well as the worst 10% and
    best 90% of values.<br>
    <h3>Usage Summary</h3>
    <tt><small>verify&nbsp; [-options] target.ti3 measured.ti3<br>
        &nbsp;-v&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;

        &nbsp; Verbose - print each patch value<br>
        &nbsp;-n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Normalise

        each files reading to white Y<br>
        &nbsp;-N&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Normalise

        each files reading to white XYZ<br>
        &nbsp;-D&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Use

        D50 100.0 as L*a*b* white reference<br>
        &nbsp;-c&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;

        &nbsp; Show CIE94 delta E values<br>
        &nbsp;-k &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
        &nbsp; &nbsp; Show CIEDE2000 delta E values<br>
        &nbsp;-s &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
        &nbsp; &nbsp; Sort patch value by error<br>
        &nbsp;-w&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;

        &nbsp; create VRML vector visualisation (measured.wrl)<br>
      </small></tt><tt><small>&nbsp;-W
        &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
        &nbsp; &nbsp; create VRML marker &amp; vector visualisation
        (measured.wrl)</small></tt><tt><br>
    </tt><tt> </tt><tt><small>&nbsp;-x&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;

        &nbsp; Use VRML axes<br>
        &nbsp;</small></tt><tt><small><small>-f
          [illum]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Use Fluorescent
          Whitening Agent compensation [opt. simulated inst. illum.:<br>
          &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;

          M0, M1, M2, A, C, D50 (def.), D50M2, D65, F5, F8, F10 or
          file.sp]<br>
          &nbsp;-i illum&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
          Choose illuminant for computation of CIE XYZ from spectral
          data &amp; FWA:<br>
          &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;

          A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp<br>
          &nbsp;-o observ&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; Choose
          CIE Observer for spectral data:<br>
        </small><small>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;

          1931_2 </small><small>(def.)</small><small>, 1964_10, S&amp;B
          1955_2, shaw, J&amp;V 1978_2</small><br>
        &nbsp;<i>target.ti3</i>&nbsp;&nbsp;&nbsp;&nbsp; &nbsp; Target or
        reference patch data file<br>
        &nbsp;<i>measured.ti3</i> &nbsp; &nbsp; Measured or actual patch
        data file</small></tt><br>
    <h3>Usage Details and Discussion</h3>
    <b> verify</b> provides a way of verifying how well a color
    transformation (such a proofing) performs.<br>
    <br>
    The <b>-v</b> flag prints out extra information during the
    checking, and prints each patch value, rather than just a summary.<br>
    <br>
    The <b>-n</b> flag causes the two sets of values to be normalized
    to the Y value of white for each set before comparison. White is
    assumed to be the patch with the largest Y value.<br>
    <br>
    The <b>-N</b> flag causes the two sets of values to be normalized
    to the XYZ of white for each set before comparison. White is assumed
    to be the patch with the largest Y value.<br>
    <br>
    The <b>-D</b> flag causes the white reference point for the
    conversion to L*a*b* to be D50 with a Y value of 100%. By default
    the sample with the largest Y value is found, and the L*a*b* white
    reference scaled to have that Y value. This allows sensible delta E
    values when comparing absolute color values, such as those from
    emission or display measurements.<br>
    <br>
    The <b>-c</b> option causes the differences between the test values
    and the profile prediction of the color for each device value to be
    displayed in CIE94 delta E, rather than plain L*a*b* delta E. CIE94
    delta E has a closer correspondence with perceived color differences
    than the default CIE76 delta E values.<br>
    <br>
    The <b>-k</b> option causes the differences between the test values
    and the profile prediction of the color for each device value to be
    displayed in CIEDE2000 delta E, rather than plain L*a*b* delta E.
    CIEDE2000 delta E has a closer correspondence with perceived color
    differences than either CIE76 or CIE94 delta E values.<br>
    <br>
    If the <b>-s </b>flag is used in combination with the <b>-v</b>
    flag, then the test point by test point output will be sorted from
    worst to best.<br>
    <br>
    The <b>-w</b> creates a <a href="File_Formats.html#VRML">VRML</a>
    3D visualization of the differences between the test points in D50
    L*a*b* space, each difference being shown as a line vector. If the <span
      style="font-weight: bold;">-W</span> flag is used, then the target
    and measured values will also be marked by a small sphere. This can
    be used to visualize the placement of values in a .ti3 (or other
    CGATS file) by using the same file for both "target" and "measured"
    values.<br>
    <br>
    The <b>-x</b> flag adds Lab axes to the VRML output.<br>
    <br>
    The <b>-f</b> flag enables Fluorescent Whitening Agent (FWA)
    compensation. This only works if spectral data is available and, the
    instrument is not UV filtered.&nbsp; FWA compensation adjusts the
    spectral samples so that they appear to have been measured using an
    illuminant that has a different level of Ultra Violet to the one the
    instrument actually used in the measurement. The optional
    illumination parameter allows specifying a standard or custom
    illumination spectrum to be used as the similated instrument
    illuminant, overriding the default <b>D50</b> or CIE computation
    illuminant used for FWA (see <b>-i</b> below<b>). </b>See <a
      href="colprof.html#f">colprof -f</a> for a fuller explanation. The
    same value should be used as was used during the creation of the
    profile.<br>
    <br>
    The <b>-i</b> flag allows specifying a standard or custom
    illumination spectrum, applied to the spectral test point values to
    compute CIE tristimulus values. <b>A</b>, <b>D50</b>, <b>D50M2,
      D65</b>, <b>F5</b>, <b>F8</b>, <b>F10</b> are a selection of
    standard illuminant spectrums, with <b>D50</b> being the default.
    If a filename is specified instead, it will be assumed to be an
    Argyll specific <a href="File_Formats.html#.sp">.sp</a> spectrum
    file. If FWA compensation is used during measurement, this
    illuminant will be used by default as the simulated instrument
    illuminant. The same value should be used as was used during the
    creation of the profile.<br>
    <br>
    The <b>-o</b> flag allows specifying a tristimulus observer, and is
    used to compute PCS (Profile Connection Space) tristimulus values.
    The following choices are available:<br>
    <b>&nbsp; 1931_2</b> selects the standard CIE 1931 2 degree
    observer. The default.<br>
    &nbsp; <b>1964_10</b> selects the standard CIE 1964 10 degree
    observer.<br>
    &nbsp; <b>1955_2</b> selects the Stiles and Birch 1955 2 degree
    observer<br>
    &nbsp; <b>1978_2 </b>selects the Judd and Voss 1978 2 degree
    observer<br>
    &nbsp; <b>shaw</b> selects the Shaw and Fairchild 1997 2 degree
    observer<br>
    <br>
    The same parameter value should be used as was used during the
    creation of the profile.<br>
    <br>
    If both CIE and spectral values are present in the input files, the
    CIE values will be used by default. Using the <span
      style="font-weight: bold;">-i</span>, <span style="font-weight:
      bold;">-o</span> or <span style="font-weight: bold;">-f</span>
    flag will force spectral values to be used. The the <span
      style="font-weight: bold;">-i</span>, <span style="font-weight:
      bold;">-o</span> or <span style="font-weight: bold;">-f</span>
    flags will apply to both the target and measured input files.<br>
    <br>
    <br>
    <br>
    <br>
    <br>
    <br>