1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
|
#ifndef INST_H
/*
* instlib API definition.
*
* See spotread.c, chartread.c, illumread.c & ccxxmake.c for examples of
* the API usage.
*
* Abstract base class for common color instrument interface
* and other common instrument stuff.
*/
/*
* Argyll Color Correction System
*
* Author: Graeme W. Gill
* Date: 15/3/2001
*
* Copyright 2001 - 2013 Graeme W. Gill
* All rights reserved.
*
* This material is licenced under the GNU GENERAL PUBLIC LICENSE Version 2 or later :-
* see the License2.txt file for licencing details.
*
*/
/*
If you make use of the instrument driver code here, please note
that it is the author(s) of the code who take responsibility
for its operation. Any problems or queries regarding driving
instruments with the Argyll drivers, should be directed to
the Argyll's author(s), and not to any other party.
If there is some instrument feature or function that you
would like supported here, it is recommended that you
contact Argyll's author(s) first, rather than attempt to
modify the software yourself, if you don't have firm knowledge
of the instrument communicate protocols. There is a chance
that an instrument could be damaged by an incautious command
sequence, and the instrument companies generally cannot and
will not support developers that they have not qualified
and agreed to support.
*/
#include "dev.h" /* Base device class */
#include "insttypes.h" /* libinst Includes this functionality */
#include "disptechs.h" /* libinst Includes this functionality */
#include "icoms.h" /* libinst Includes this functionality */
#include "conv.h"
#ifdef __cplusplus
extern "C" {
#endif
/* ------------------------------------------------- */
/* aprox. debug level guide:
1,2 Applications, internal errors
2,3 High level instrument drivers
4,5 High level instrument communications
6,7 High level serial/USB communications
8,9 Low level serial/USB communications
*/
/* ------------------------------------------------- */
/* Structure for holding an instrument patch reading */
#ifdef NEVER /* Declared in xicc/xspect.h */
/* Type of measurement result */
typedef enum { /* XYZ units, Spectral units */
inst_mrt_none = 0, /* Not set */
inst_mrt_emission = 1, /* cd/m^2, mW/(m^2.sr.nm) */
inst_mrt_ambient = 2, /* Lux mW/(m^2.nm) */
inst_mrt_emission_flash = 3, /* cd.s/m^2, mW.s/(m^2.sr.nm) */
inst_mrt_ambient_flash = 4, /* Lux.s mW.s/(m^2.nm) */
inst_mrt_reflective = 5, /* %, %/nm */
inst_mrt_transmissive = 6, /* %, %/nm */
inst_mrt_frequency = 7 /* Hz */
} inst_meas_type;
#endif // NEVER
#define ICOM_MAX_LOC_LEN 10
struct _ipatch {
char loc[ICOM_MAX_LOC_LEN]; /* patch location */
inst_meas_type mtype; /* Measurement type */
int XYZ_v; /* XYZ valid */
double XYZ[3]; /* XYZ values */
xspect sp; /* Spectrum. sp.spec_n > 0 if valid */
/* Reflectance/Transmittance 0.0 .. 100.0%, norm = 100.0 */
/* or mW/nm/m^2, norm = 1.0, etc. */
double duration; /* Apparent total duration in seconds (flash measurement) */
/* Typicall limited to sampling rate of instrument. */
}; typedef struct _ipatch ipatch;
/* ---------------------------------------- */
/* Instrument interface abstract base class */
/* Abstract return codes in ms 8bits. */
/* Instrument dependant codes in ls 16 bits. */
/* Note :- update inst_interp_error() in inst.c if anything here is changed. */
/* and also check all the instrument specific XXX_interp_code() routines too. */
typedef enum {
inst_ok = 0x000000,
inst_notify = 0x010000, /* A Notification */
inst_warning = 0x020000, /* A Warning */
inst_no_coms = 0x030000, /* init_coms() hasn't been called yet */
inst_no_init = 0x040000, /* init_inst() hasn't been called yet */
inst_unsupported = 0x050000, /* Unsupported function */
inst_internal_error = 0x060000, /* Internal software error */
inst_coms_fail = 0x070000, /* Communication failure */
inst_unknown_model = 0x080000, /* Not the expected instrument */
inst_protocol_error = 0x090000, /* Read or Write protocol error */
inst_user_abort = 0x0A0000, /* User hit escape */
inst_user_trig = 0x0C0000, /* User hit trigger key */
inst_misread = 0x0E0000, /* Bad reading, or strip misread */
inst_nonesaved = 0x0F0000, /* No saved data to read */
inst_nochmatch = 0x100000, /* Chart doesn't match */
inst_needs_cal = 0x110000, /* Instrument needs calibration, and read retried */
inst_cal_setup = 0x120000, /* Calibration retry with correct setup is needed */
inst_wrong_config = 0x130000, /* Retry with correct inst. config./sensor posn. needed */
inst_unexpected_reply = 0x140000, /* Unexpected Reply */
inst_wrong_setup = 0x150000, /* Setup is wrong or conflicting */
inst_hardware_fail = 0x160000, /* Hardware failure */
inst_system_error = 0x170000, /* System call (ie malloc) fail */
inst_bad_parameter = 0x180000, /* Bad parameter value */
inst_other_error = 0x190000, /* Some other error */
inst_mask = 0xff0000, /* inst_code mask value */
inst_imask = 0x00ffff /* instrument specific mask value */
} inst_code;
/*
possible UV modes:
Do the reflective measurement with UV rather than normal illuminant
[ Should this be reflectivity against 'A', or absolute ?? ]
(ie. spot, strip, xy or chart). inst_mode_ref_uv
Do a white & UV measurement at the start of each strip reading.
Return result with special call after each strip read.
inst_mode_ref_uv_strip_1
Do a dual white & UV measurement
[ Can do in one hit for spot, but how should two strip passes be handled ?
ie. two separate strip reads of phase 1 & then 2 ? ]
(ie. spot, strip, xy or chart). inst_mode_ref_uv_2pass
Get normal illuminant spectrum.
Get UV spectrum.
get_meas_illum_spectrum(mode);
*/
/* Instrument capabilities & modes */
/* Note that due to the binary combinations, capabilities is not definititive */
/* as to valid modes. check_mode() is definitive. */
/* #defines are for saving modes in a version independent way. */
/* Note :- update inst_mode_sym[] table in inst.c if anything here is changed. */
typedef enum {
inst_mode_none = 0x00000000, /* No capability or mode */
/* Light measurement mode */
inst_mode_reflection = 0x00000001, /* General reflection mode */
# define inst_mode_reflection_sym "REFL"
inst_mode_s_reflection = 0x00000002, /* General saved reflection mode */
# define inst_mode_s_reflection_sym "SRFL"
inst_mode_transmission = 0x00000004, /* General transmission mode */
# define inst_mode_transmission_sym "TRAN"
inst_mode_emission = 0x00000008, /* General emission mode */
# define inst_mode_emission_sym "EMIS"
inst_mode_illum_mask = 0x0000000f, /* Mask of sample illumination sub mode */
/* Action of measurement */
inst_mode_spot = 0x00000010, /* General spot measurement mode */
# define inst_mode_spot_sym "SPOT"
inst_mode_strip = 0x00000020, /* General strip measurement mode */
# define inst_mode_strip_sym "STRP"
inst_mode_xy = 0x00000040, /* General X-Y measurement mode */
# define inst_mode_xy_sym "CHXY"
inst_mode_chart = 0x00000080, /* General chart measurement mode */
# define inst_mode_chart_sym "CHRT"
inst_mode_ambient = 0x00000100, /* General ambient measurement mode */
# define inst_mode_ambient_sym "AMBI"
inst_mode_ambient_flash = 0x00000200, /* General ambient flash measurement mode */
# define inst_mode_ambient_flash_sym "ABFL"
inst_mode_tele = 0x00000400, /* General telephoto measurement mode */
# define inst_mode_tele_sym "TELE"
// Hmm. Should there be a tele_flash mode ????
inst_mode_sub_mask = 0x000007f0, /* Mask of sub-mode */
/* Basic mode */
inst_mode_basic_mask = inst_mode_illum_mask | inst_mode_sub_mask,
/* Extra dependent modes */
inst_mode_emis_nonadaptive = 0x00000800, /* Emissom Non-adaptive mode */
# define inst_mode_emis_nonadaptive_sys "EMNA"
inst_mode_ref_uv = 0x00001000, /* Ultra Violet measurement mode */
# define inst_mode_ref_uv_sym "REUV"
inst_mode_emis_refresh_ovd = 0x00002000, /* Emissom Refresh mode override */
# define inst_mode_emis_refresh_ovd_sym "EMRO"
inst_mode_emis_norefresh_ovd = 0x00006000, /* Emissom Non-refresh mode override */
# define inst_mode_emis_norefresh_ovd_sym "ENRO"
inst_mode_dep_extra_mask = 0x00007800, /* Mask of measurement modifiers */
/* Extra independent modes */
inst_mode_colorimeter = 0x00004000, /* Colorimetric mode */
# define inst_mode_colorimeter_sym "COLI"
inst_mode_spectral = 0x00008000, /* Spectral mode */
# define inst_mode_spectral_sym "SPEC"
inst_mode_highres = 0x00010000, /* High Resolution Spectral mode */
# define inst_mode_highres_sym "HIRZ"
inst_mode_extra_mask = 0x0001c000, /* Mask of extra modes */
/* Configured for calibration & capable of returning it from inst_mode_calibration */
inst_mode_calibration = 0x80000000, /* Configured for calibration */
# define inst_mode_calibration_sym "CALB"
/* Combined operating modes (from above): */
/* These mode capabilities are also use to set the mode */
/* Test for a mode should be IMODETST(flags, mode) */
inst_mode_ref_spot = inst_mode_spot /* Reflection spot measurement mode */
| inst_mode_reflection,
inst_mode_ref_strip = inst_mode_strip /* Reflection strip measurement mode */
| inst_mode_reflection,
inst_mode_ref_xy = inst_mode_xy /* Reflection X-Y measurement mode */
| inst_mode_reflection,
inst_mode_ref_chart = inst_mode_chart /* Reflection Chart measurement mode */
| inst_mode_reflection,
inst_mode_s_ref_spot = inst_mode_spot /* Saved reflection spot measurement mode */
| inst_mode_s_reflection,
inst_mode_s_ref_strip = inst_mode_strip /* Saved reflection strip measurement mode */
| inst_mode_s_reflection,
inst_mode_s_ref_xy = inst_mode_xy /* Saved reflection X-Y measurement mode */
| inst_mode_s_reflection,
inst_mode_s_ref_chart = inst_mode_chart /* Saved reflection Chart measurement mode */
| inst_mode_s_reflection,
inst_mode_trans_spot = inst_mode_spot /* Transmission spot measurement mode */
| inst_mode_transmission, /* Normal Diffuse/90 */
inst_mode_trans_spot_a = inst_mode_ambient /* Transmission spot measurement mode */
| inst_mode_transmission, /* Alternate 90/diffuse */
inst_mode_trans_strip = inst_mode_strip /* Transmission strip measurement mode */
| inst_mode_transmission,
inst_mode_trans_xy = inst_mode_xy /* Transmission X-Y measurement mode */
| inst_mode_transmission,
inst_mode_trans_chart = inst_mode_chart /* Transmission chart measurement mode */
| inst_mode_transmission,
inst_mode_emis_spot = inst_mode_spot /* Spot emission measurement mode */
| inst_mode_emission,
inst_mode_emis_tele = inst_mode_tele /* Telephoto emission measurement mode */
| inst_mode_emission,
inst_mode_emis_ambient = inst_mode_ambient /* Ambient emission measurement mode */
| inst_mode_emission,
inst_mode_emis_ambient_flash = inst_mode_ambient_flash /* Ambient emission flash measurement */
| inst_mode_emission,
inst_mode_emis_strip = inst_mode_strip /* Strip emission measurement mode */
| inst_mode_emission,
inst_mode_measurement_mask = inst_mode_illum_mask /* Mask of exclusive measurement modes */
| inst_mode_sub_mask
| inst_mode_dep_extra_mask
} inst_mode;
/* Test for a specific mode */
/* (This isn't foolproof - it->check_mode() is better for modes */
/* composed of more than one bit) */
#define IMODETST(mbits, mode) (((mbits) & (mode)) == (mode))
/* Test for a specific mode in capability and mode */
#define IMODETST2(mcap, mbits, mode) (IMODETST(mcap, mode) && IMODETST(mbits, mode))
#define MAX_INST_MODE_SYM_SZ (32 * (4 + 1)) /* Each bit sym is 4 chars */
/* Return a string with a symbolic encoding of the mode flags */
void inst_mode_to_sym(char sym[MAX_INST_MODE_SYM_SZ], inst_mode mode);
/* Return a set of mode flags that correspond to the symbolic encoding */
/* Return nz if a symbol wasn't recognized */
int sym_to_inst_mode(inst_mode *mode, const char *sym);
/* Instrument capabilities 2 */
/* (Available capabilities may be mode dependent) */
typedef enum {
inst2_none = 0x00000000, /* No capabilities */
inst2_xy_holdrel = 0x00000001, /* Needs paper hold/release between each sheet */
inst2_xy_locate = 0x00000002, /* Needs user to locate patch locations */
inst2_xy_position = 0x00000004, /* Can be positioned at a given location */
inst2_meas_disp_update = 0x00000010, /* Is able to measure display update delay */
inst2_get_refresh_rate = 0x00000020, /* Is able to get the calibrated refresh rate */
inst2_set_refresh_rate = 0x00000040, /* Is able to set the calibrated refresh rate */
inst2_emis_refr_meas = 0x00000080, /* Has an emissive refresh rate measurement func. */
inst2_prog_trig = 0x00000100, /* Progromatic trigger measure capability */
inst2_user_trig = 0x00000200, /* User trigger measure capability, */
/* i.e. via user button and uicallback. */
inst2_switch_trig = 0x00000400, /* Inst. switch trigger measure capability, */
/* i.e. instrument directly starts measurement */
/* via mechanical switch. */
inst2_user_switch_trig = 0x00000800, /* User or switch trigger measure capability */
inst2_bidi_scan = 0x00001000, /* Try and recognise patches scanned from either dir. */
inst2_cal_using_switch = 0x00002000, /* DTP22 special - use switch triggered calibration */
inst2_has_scan_toll = 0x00004000, /* Instrument will honour modified scan tollerance */
inst2_no_feedback = 0x00008000, /* Instrument doesn't give any user feedback */
inst2_opt_calibs = 0x00010000, /* Instrument has optional calibrations */
inst2_has_leds = 0x00200000, /* Instrument has some user viewable indicator LEDs */
inst2_has_target = 0x00400000, /* Instrument has aiming target */
inst2_has_sensmode = 0x00800000, /* Instrument can report it's sensors mode */
inst2_has_battery = 0x01000000, /* Instrument is battery powered */
inst2_disptype = 0x02000000, /* Has a display/calibration type selector */
/* (ie. get_disptypesel(), set_disptype */
inst2_ccmx = 0x04000000, /* Colorimeter Correction Matrix capability */
inst2_ccss = 0x08000000, /* Colorimeter Cal. Spectral Set capability */
inst2_ambient_mono = 0x10000000, /* The ambient measurement is monochrome */
inst2_ambient_cardioid = 0x20000000, /* The ambient measurement has a cardioid response */
inst2_get_min_int_time = 0x40000000, /* Is able to get the minimum integration time */
inst2_set_min_int_time = 0x80000000 /* Is able to set the minimum integration time */
} inst2_capability;
/* Instrument capabilities 3 (room for expansion) */
/* (Available capabilities may be mode dependent) */
typedef enum {
inst3_none = 0x00000000, /* No capabilities */
inst3_average = 0x00000001 /* Can set to average multiple measurements into 1 */
/* See inst_opt_set_averages */
} inst3_capability;
/* - - - - - - - - - - - - - - - - - - - */
/* API ideas for supporting calibration management:
functions to:
return number of used and free builtin slots, + password required flag.
write builtin calibration or ccss/ccmx file
write builtin calibration or ccss/ccmx file
delete builtin calibration or ccss/ccmx file
Things to be allowed for:
optional password
configuration specific calibrations. How are they marked ?
Also for ccss capable instruments:
write corresponding ccmx for given ccss.
*/
typedef enum {
inst_dtflags_none = 0x0000, /* no flags - assume builtin calibration */
inst_dtflags_mtx = 0x0001, /* matrix read from instrument */
inst_dtflags_ccss = 0x0002, /* ccss file */
inst_dtflags_ccmx = 0x0004, /* ccmx file */
inst_dtflags_custom = 0x0010, /* custom (i.e. not built in or OEM) */
inst_dtflags_wr = 0x0020, /* Writable slot */
inst_dtflags_ld = 0x0040, /* mtx/ccss/ccmx is loaded */
inst_dtflags_default = 0x1000, /* Default calibration to use */
inst_dtflags_end = 0x8000 /* end marker */
} inst_dtflags;
#define INST_DTYPE_SEL_LEN 10
#define INST_DTYPE_DESC_LEN 100
/* Structure used to return display type selection information. */
/* Calibrations may be implicit (based on ix and driver code), or */
/* explicit mtx/ccss/ccmx information contained in structure. */
typedef struct _inst_disptypesel {
/* Public: */
inst_dtflags flags; /* Attribute flags */
int cbid; /* Calibration base ID. NZ if valid ccmx calibration base. */
/* Should remain constant between releases */
char sel[INST_DTYPE_SEL_LEN]; /* String of selector character aliases */
char desc[INST_DTYPE_DESC_LEN]; /* Textural description */
int refr; /* Refresh mode flag */
disptech dtech; /* display techology */
/* Private: */
int ix; /* Internal index, */
char isel[INST_DTYPE_SEL_LEN]; /* String of potential selector characters */
// Stuff for ccss & ccmx
char *path; /* Path to ccss or ccmx. NULL if not valid */
int cc_cbid; /* cbid that matrix requires */
double mat[3][3]; /* ccmx matrix */
xspect *sets; /* ccss set of sample spectra. NULL if not valid */
int no_sets; /* ccs number of sets. 0 if not valid */
} inst_disptypesel;
/* - - - - - - - - - - - - - - - - - - - */
/* Instrument options for get_set_opt() */
typedef enum {
inst_opt_unknown = 0x0000, /* Option not specified */
inst_stat_saved_readings = 0x0001, /* Return status of saved reading values */
/* [1 argument type *inst_stat_savdrd] */
inst_stat_s_spot = 0x0002, /* Return number of saved spot readings */
/* [1 argument type *int] */
inst_stat_s_strip = 0x0003, /* Return saved strip details */
/* [args: int *no_patches, int *no_rows */
/* int *pat_per_row] */
inst_stat_s_xy = 0x0004, /* Return saved strip details */
/* [args: int *no_sheets, int *no_patches, */
/* int *no_rows, int *pat_per_row] */
inst_stat_s_chart = 0x0005, /* Return number saved chart details */
/* [args: int *no_patches, int *no_rows */
/* int *pat_per_row, int *chart_id, */
/* int *missing_row ] */
inst_stat_battery = 0x0006, /* Return charged status of battery */
/* [1 argument type *double : range 0.0 - 1.0 ] */
inst_stat_get_filter = 0x0007, /* Get a filter configuration */
/* [1 argument type *inst_opt_filter ] */
inst_opt_initcalib = 0x0008, /* Enable initial calibration (default) [No args] */
inst_opt_noinitcalib = 0x0009, /* Disable initial calibration if < losecs since last */ /* opened, or losecs == 0 [int losecs] */
inst_opt_askcalib = 0x000A, /* Ask before proceeding with calibration (default) */
/* [ No args] */
inst_opt_noaskcalib = 0x000B, /* Proceed with calibration immediately if possible */
/* [ No args] */
inst_opt_set_ccss_obs = 0x000C, /* Set the observer used with ccss device types - */
/* Not applicable to any other type of instrument. */
/* [args: icxObserverType obType,*/
/* xspect custObserver[3] */
inst_opt_set_filter = 0x000D, /* Set a filter configuration */
/* [1 argument type inst_opt_filter] */
inst_opt_trig_prog = 0x000E, /* Trigger progromatically [No args] */
inst_opt_trig_user = 0x000F, /* Trigger from user via uicallback [No args] */
inst_opt_trig_switch = 0x0010, /* Trigger directly using instrument switch [No args] */
inst_opt_trig_user_switch = 0x0011, /* Trigger from user via uicallback or switch (def) [No args] */
inst_opt_highres = 0x0012, /* Enable high res spectral mode indep. of set_mode() */
inst_opt_stdres = 0x0013, /* Revert to standard resolution spectral mode */
inst_opt_scan_toll = 0x0014, /* Modify the patch scan recognition tollnce [double] */
inst_opt_get_gen_ledmask = 0x0015, /* Get the bitmask for general indication LEDs [*int] */
/* (More specialized indicator masks go here) */
inst_opt_set_led_state = 0x0016, /* Set the current LED state. 0 = off, 1 == on [int] */
inst_opt_get_led_state = 0x0017, /* Get the current LED state. 0 = off, 1 == on [*int] */
inst_opt_get_pulse_ledmask = 0x0018, /* Get the bitmask for pulseable ind. LEDs [*int] */
inst_opt_set_led_pulse_state= 0x0019, /* Set the current LED state. [double period_in_secs, */
/* double on_time_prop, double trans_time_prop] */
inst_opt_get_led_pulse_state= 0x001A, /* Get the current pulse LED state. [*double period] */
inst_opt_get_target_state = 0x001B, /* Get the aiming target state 0 = off, 1 == on [*int] */
inst_opt_set_target_state = 0x001C, /* Set the aiming target state 0 = off, 1 == on, 2 = toggle [int] */
inst_opt_get_min_int_time = 0x001D, /* Get the minimum integration time [*double time] */
inst_opt_set_min_int_time = 0x001E, /* Set the minimum integration time [double time] */
inst_opt_opt_calibs_valid = 0x001F, /* Are optional (white/black/gloss etc.) calibrations */
/* valid? [*int valid] */
inst_opt_clear_opt_calibs = 0x0020, /* Clear all optional calibrations. */
inst_opt_get_cal_tile_sp = 0x0021, /* Return refl. white tile reference spectrum. */
/* for current filter. [*xspect tile] */
inst_opt_set_xcalstd = 0x0022, /* Set the X-Rite reflective calibration standard */
/* [xcalstd standard] */
inst_opt_get_xcalstd = 0x0023, /* Get the effective X-Rite ref. cal. standard */
/* [xcalstd *standard] */
inst_opt_lamp_remediate = 0x0024, /* Remediate i1Pro lamp [double seconds] */
inst_opt_set_averages = 0x0025 /* Set the number of measurements to average [int] */
/* 0 for default */
} inst_opt_type;
/* Optional filter fitted to instrument (for inst_opt_set_filter) */
/* Set this before calling init_coms() */
typedef enum {
inst_opt_filter_unknown = 0xffff, /* Unspecified filter */
inst_opt_filter_none = 0x0000, /* No filters fitted */
inst_opt_filter_pol = 0x0001, /* Polarising filter */
inst_opt_filter_D65 = 0x0002, /* D65 Illuminant filter */
inst_opt_filter_UVCut = 0x0004, /* U.V. Cut filter */
inst_opt_filter_Custom = 0x0008 /* Custom Filter */
} inst_opt_filter;
/* Off-line pending readings available (status) */
typedef enum {
inst_stat_savdrd_none = 0x00, /* No saved readings */
inst_stat_savdrd_spot = 0x01, /* There are saved spot readings available */
inst_stat_savdrd_strip = 0x02, /* There are saved strip readings available */
inst_stat_savdrd_xy = 0x04, /* There are saved page readings available */
inst_stat_savdrd_chart = 0x08 /* There are saved chart readings available */
} inst_stat_savdrd;
/* Type of calibration needed/available/requested - corresponds to capabilities */
/* [ inst_calt_trans_vwhite is "variable" white transmission calibration, needed */
/* where transmission mode is being emulated. ] */
/* Remember to update calt2str() */
typedef enum {
/* Response to needs_calibration() */
inst_calt_none = 0x00000000, /* No calibration or unknown */
/* Psudo-calibration types */
inst_calt_all = 0x00000001, /* Do required non-deferable cals for mode, but also */
/* do all possible calibrations for all other modes */
/* using the calibration conditions. This may be slow */
/* Hmm. We don't have an "calt_all_needed" - do all needed cals of all possible modes. */
/* This might be more useful than inst_calt_all ? */
inst_calt_needed = 0x00000002, /* Do all required non-deferable cals for c.m. */
inst_calt_available = 0x00000003, /* Do all available non-deferable cals for c.m. */
/* Specific type of calibration - corresponds to capabilities */
inst_calt_wavelength = 0x00000010, /* Wavelength calibration using refl. cal. surface */
inst_calt_ref_white = 0x00000020, /* Reflective white/emissive dark calibration */
inst_calt_ref_dark = 0x00000040, /* Reflective dark calibration (light trap) */
inst_calt_ref_dark_gl = 0x00000080, /* Reflective gloss calibration (black gloss surface) */
inst_calt_emis_offset = 0x00000100, /* Emissive offset/black calibration (dark surface) */
inst_calt_emis_ratio = 0x00000200, /* Emissive ratio calibration */
inst_calt_em_dark = 0x00000400, /* Emissive dark calibration (in dark) */
inst_calt_trans_white = 0x00000800, /* Transmissive white reference calibration */
inst_calt_trans_vwhite = 0x00001000, /* Transmissive variable white reference calibration */
inst_calt_trans_dark = 0x00002000, /* Transmissive dark reference calibration */
inst_calt_n_dfrble_mask = 0x0000fff0, /* Mask of non-deferrable calibrations */
/* Calibrations that might be deferred until measurement */
inst_calt_emis_int_time = 0x00100000, /* Emissive measurement range (integration time) */
inst_calt_ref_freq = 0x00200000, /* Display refresh frequency calibration */
inst_calt_dfrble_mask = 0x00f00000, /* Mask of deferrable calibrations */
inst_calt_all_mask = 0x00f0fff0, /* Mask of all specific calibrations */
inst_calt_ap_flag = 0x80000000 /* Implementation flag indicating do all possible */
} inst_cal_type;
/* Return a description of the first calibration type */
char *calt2str(inst_cal_type calt);
/* Calibration conditions. */
/* This is how the instrument communicates to the calling program */
/* about how to facilitate a calibration, or what it's current measurement */
/* configuration provides. */
/* [There is no provission for explictly indicating calibrations that can be */
/* performed automatically and transparently by the instrument - for instance */
/* in the case of the spectroscan, since the required condition can be obtained */
/* without the users interaction. ] */
typedef enum {
inst_calc_none = 0x00000000, /* Not suitable for calibration */
inst_calc_unknown = 0xffffffff, /* Unknown calibration setup */
/* uop means that user has to trigger the within instrument */
/* calibration using its "front panel" or other direct keys */
inst_calc_uop_ref_white = 0x00000001, /* user operated reflective white calibration */
inst_calc_uop_trans_white = 0x00000002, /* user operated tranmissive white calibration */
inst_calc_uop_trans_dark = 0x00000003, /* user operated tranmissive dark calibration */
inst_calc_uop_mask = 0x0000000F, /* user operated calibration mask */
/* Man means that the user has to manualy configure the instrument */
/* to be on the correct reference for the software triggered cal. */
inst_calc_man_ref_white = 0x00000010, /* place instrument on reflective white reference */
inst_calc_man_ref_whitek = 0x00000020, /* click instrument on reflective white reference */
inst_calc_man_ref_dark = 0x00000030, /* place instrument on light trap */
inst_calc_man_dark_gloss = 0x00000040, /* place instrument on gloss black reference */
inst_calc_man_em_dark = 0x00000050, /* place cap on instrument, put on dark surface or white ref. */
inst_calc_man_am_dark = 0x00000060, /* Place cap over ambient sensor (wl calib capable) */
inst_calc_man_cal_smode = 0x00000070, /* Put instrument sensor in calibration position */
inst_calc_man_trans_white = 0x00000080, /* place instrument on transmissive white reference */
inst_calc_man_trans_dark = 0x00000090, /* place instrument on transmissive dark reference */
inst_calc_man_man_mask = 0x000000F0, /* user configured calibration mask */
inst_calc_emis_white = 0x00000100, /* Provide a white test patch */
inst_calc_emis_80pc = 0x00000200, /* Provide an 80% white test patch */
inst_calc_emis_grey = 0x00000300, /* Provide a grey test patch */
inst_calc_emis_grey_darker = 0x00000400, /* Provide a darker grey test patch */
inst_calc_emis_grey_ligher = 0x00000500, /* Provide a darker grey test patch */
inst_calc_emis_mask = 0x00000F00, /* Emmissive/display provided reference patch */
inst_calc_change_filter = 0x00010000, /* Filter needs changing on device - see id[] */
inst_calc_message = 0x00020000, /* Issue a message. - see id[] */
inst_calc_cond_mask = 0x0fffffff, /* Mask for conditions (i.e. remove flags) */
inst_calc_optional_flag = 0x80000000 /* Flag indicating calibration can be skipped */
} inst_cal_cond;
/* Condition identifier message type. This can be useful in internationalizing the */
/* string returned in id[] from calibrate() */
typedef enum {
inst_calc_id_none = 0x00000000, /* No id */
inst_calc_id_ref_sn = 0x00000001, /* Calibration reference (ie. tile) serial number */
inst_calc_id_trans_low = 0x00010000, /* Trans. Ref. light is too low for accuracy warning */
inst_calc_id_trans_wl = 0x00020000, /* Trans. Ref. light is low at some wavelengths warning */
inst_calc_id_filt_unkn = 0x00100000, /* Request unknown filter */
inst_calc_id_filt_none = 0x00200000, /* Request no filter */
inst_calc_id_filt_pol = 0x00300000, /* Request polarizing filter */
inst_calc_id_filt_D65 = 0x00400000, /* Request D65 filter */
inst_calc_id_filt_UV = 0x00500000, /* Request UV cut filter */
inst_calc_id_filt_cust = 0x00600000 /* Request custom filter */
} inst_calc_id_type;
/* Clamping state */
typedef enum {
instNoClamp = 0, /* Don't clamp XYZ/Lab to +ve */
instClamp = 1, /* Clamp XYZ/Lab to +ve */
} instClamping;
/* User interaction callback (uicallback()) function purpose */
typedef enum {
inst_negcoms, /* Negotiating communications - can abort */
inst_armed, /* Armed and waiting for a measurement trigger - can wait, trigger, abort */
inst_triggered, /* Measurement triggered by switch or user (not progromatic) - notice */
/* (Also triggered by switch driven calibration,i.e. DTP41) */
inst_measuring /* Busy measuring - can abort */
} inst_ui_purp;
/* Asynchronous event callback type */
typedef enum {
inst_event_switch, /* Instrument measure/calibrate switch pressed. */
inst_event_mconf, /* Change in measurement configuration (ie. sensor position) */
inst_event_scan_ready /* Ready for manual strip scan (i.e. issue audible prompt) */
} inst_event_type;
/* Instrument configuration/sensor position*/
typedef enum {
inst_conf_unknown,
inst_conf_projector,
inst_conf_surface,
inst_conf_emission,
inst_conf_calibration,
inst_conf_ambient
} inst_config;
# define EXTRA_INST_OBJ
/* Off-line pending readings available (status) */
#define CALIDLEN 200 /* Maxumum length of calibration tile ID string */
/* Color instrument interface base object */
/* Note that some methods work after creation, while many */
/* will return an error if communications hasn't been established and */
/* the instrument initialised. Some may change their response before and */
/* after initialisation. */
#define INST_OBJ_BASE \
\
DEV_OBJ_BASE \
\
EXTRA_INST_OBJ \
\
double cal_gy_level; /* Display calibration test window state */ \
int cal_gy_count; /* Display calibration test window state */ \
inst_code (*uicallback)(void *cntx, inst_ui_purp purp); \
void *uic_cntx; /* User interaction callback function */ \
void (*eventcallback)(void *cntx, inst_event_type event); \
void *event_cntx; /* Asynchronous event callback function */ \
athread *scan_ready_thread; /* msec_scan_ready() support */ \
int scan_ready_delay; /* msec_scan_ready() support */ \
\
/* Virtual delete. Cleans up things done by new_inst(). */ \
inst_code (*vdel)( \
struct _inst *p); \
\
/* Establish communications at the indicated baud rate. */ \
/* (Serial parameters are ignored for USB instrument) */ \
/* Timout in to seconds, and return non-zero error code */ \
inst_code (*init_coms)( \
struct _inst *p, \
baud_rate br, /* Baud rate */ \
flow_control fc, /* Flow control */ \
double tout); /* Timeout */ \
\
/* Initialise or re-initialise the INST */ \
/* return non-zero on an error, with inst error code */ \
inst_code (*init_inst)( \
struct _inst *p); \
\
/* Return the instrument type */ \
/* (this could concievably change after init_inst()) */ \
/* Can be called before init */ \
instType (*get_itype)( \
struct _inst *p); \
\
/* Return the instrument serial number. */ \
/* (This will be an empty string if there is no serial no) */ \
char *(*get_serial_no)( \
struct _inst *p); \
\
/* Return the avilable instrument modes and capabilities. */ \
/* Can be called before init, but may be different to */ \
/* what's returned after initilisation. */ \
/* Note that these may change with the mode. */ \
/* Arguments may be NULL */ \
void (*capabilities)(struct _inst *p, \
inst_mode *cap1, \
inst2_capability *cap2, \
inst3_capability *cap3); \
\
/* Return current or given configuration available measurement modes. */ \
/* Most instruments have only one detectable configuration. */ \
/* If conf_ix == NULL or *conf_ix is an invalid configuration index, */ \
/* then the current configuration modes are returned. */ \
/* Otherwise the given configuration index is returned. */ \
/* The i1d3 has 2, the Munki has 4, one being calibration. */ \
/* *cconds is valid if *mmodes = inst_mode_calibration */ \
inst_code (*meas_config)(struct _inst *p, \
inst_mode *mmodes, /* Return all the valid measurement modes */ \
/* for the current configuration */ \
inst_cal_cond *cconds, /* Return the valid calibration conditions */ \
int *conf_ix); /* Request mode for given configuration, and */ \
/* return the index of the configuration returned */ \
\
/* Check that the particular device measurement mode is valid, */ \
/* since it's not possible to be 100% sure from capabilities */ \
inst_code (*check_mode)( \
struct _inst *p, \
inst_mode m); /* Requested mode */ \
\
/* Set the device measurement mode */ \
/* Note that this may change the capabilities. */ \
inst_code (*set_mode)( \
struct _inst *p, \
inst_mode m); /* Requested mode */ \
\
/* Return array of display type selectors */ \
inst_code (*get_disptypesel)( \
struct _inst *p, \
int *no_selectors, /* Return number of display types */ \
inst_disptypesel **sels,/* Return the array of display types */ \
int allconfig, /* nz to return list for all configs, not just current. */ \
int recreate); /* nz to re-check for new ccmx & ccss files */ \
\
/* Set the display type or calibration mode. */ \
/* index is into the inst_disptypesel[] returned */ \
/* returned by get_disptypesel(). clears col_cor_mat() and */ \
/* col_cal_spec_set(). */ \
inst_code (*set_disptype)( \
struct _inst *p, \
int index); \
\
/* Get the disptech and other corresponding info for the current */ \
/* selected display type or calibration mode. Returns disptype_unknown */ \
/* by default. Because refrmode can be overridden, it may not */ \
/* match the refrmode of the dtech. */ \
/* (Pointers may be NULL if not needed) */ \
inst_code (*get_disptechi)( \
struct _inst *p, \
disptech *dtech, \
int *refrmode, \
int *cbid); \
\
/* Get a status or get or set an option */ \
/* option state. */ \
/* Some options can be set before init */ \
/* See inst_opt_type typedef for list of mode types */ \
inst_code (*get_set_opt)( \
struct _inst *p, \
inst_opt_type m, /* Requested option mode */ \
...); /* Option parameters */ \
\
/* Read a full test chart composed of multiple sheets */ \
/* DOESN'T use the trigger mode */ \
/* Return the inst error code */ \
inst_code (*read_chart)( \
struct _inst *p, \
int npatch, /* Total patches/values in chart */ \
int pich, /* Passes (rows) in chart */ \
int sip, /* Steps in each pass (patches in each row) */ \
int *pis, /* Passes in each strip (rows in each sheet) */ \
int chid, /* Chart ID number */ \
ipatch *vals); /* Pointer to array of values */ \
\
\
/* For an xy instrument, release the paper */ \
/* (if cap has inst_xy_holdrel) */ \
/* Return the inst error code */ \
inst_code (*xy_sheet_release)( \
struct _inst *p); \
\
/* For an xy instrument, hold the paper */ \
/* (if cap has inst_xy_holdrel) */ \
/* Return the inst error code */ \
inst_code (*xy_sheet_hold)( \
struct _inst *p); \
\
/* For an xy instrument, allow the user to locate a point */ \
/* (if cap has inst_xy_locate) */ \
/* Return the inst error code */ \
inst_code (*xy_locate_start)( \
struct _inst *p); \
\
/* For an xy instrument, read back the location */ \
/* (if cap has inst_xy_locate) */ \
/* Return the inst error code */ \
inst_code (*xy_get_location)( \
struct _inst *p, \
double *x, double *y); \
\
/* For an xy instrument, end allowing the user to locate a point */ \
/* (if cap has inst_xy_locate) */ \
/* Return the inst error code */ \
inst_code (*xy_locate_end)( \
struct _inst *p); \
\
/* For an xy instrument, move the measurement point */ \
/* (if cap has inst_xy_position) */ \
/* Return the inst error code */ \
inst_code (*xy_position)( \
struct _inst *p, \
int measure, /* nz for measure point, z for locate point */ \
double x, double y); \
\
/* For an xy instrument, try and clear the table after an abort */ \
/* Return the inst error code */ \
inst_code (*xy_clear)( \
struct _inst *p); \
\
/* Read a sheet full of patches using xy mode */ \
/* DOESN'T use the trigger mode */ \
/* Return the inst error code */ \
inst_code (*read_xy)( \
struct _inst *p, \
int pis, /* Passes in strips (letters in sheet) */ \
int sip, /* Steps in pass (numbers in sheet) */ \
int npatch, /* Total patches in strip (skip in last pass) */ \
char *pname, /* Starting pass name (' A' to 'ZZ') */ \
char *sname, /* Starting step name (' 1' to '99') */ \
double ox, double oy, /* Origin of first patch */ \
double ax, double ay, /* pass increment */ \
double aax, double aay, /* pass offset for odd patches */ \
double px, double py, /* step/patch increment */ \
ipatch *vals); /* Pointer to array of values */ \
\
\
/* Read a set of strips (applicable to strip reader) */ \
/* Obeys the trigger mode set, and may return user trigger code, */ \
/* to hint that a user command may be available. */ \
/* Return the inst error code */ \
inst_code (*read_strip)( \
struct _inst *p, \
char *name, /* Strip name (up to 7 chars, for DTP51) */ \
int npatch, /* Number of patches in each pass */ \
char *pname, /* Pass name (3 chars, for DTP51) */ \
int sguide, /* Guide number (for DTP51, decrements by 5) */ \
double pwid, /* Patch width in mm (For DTP20/DTP41) */ \
double gwid, /* Gap width in mm (For DTP20/DTP41) */ \
double twid, /* Trailer width in mm (For DTP41T) */ \
ipatch *vals); /* Pointer to array of values */ \
\
\
/* Read a single sample (applicable to spot instruments) */ \
/* Obeys the trigger mode set, and may return user trigger code */ \
/* Values are in XYZ % (0..100) for reflective & transmissive, */ \
/* cd/m^2 for emissive, and Lux for ambient. */ \
/* Spectral will be analogous to the XYZ (see inst_meas_type). */ \
/* By default values may be -ve due to noise (depending on instrument) */ \
/* Return the inst error code */ \
inst_code (*read_sample)( \
struct _inst *p, \
char *name, /* Patch identifier (up to 7 chars) */ \
ipatch *val, /* Pointer to value to be returned */ \
instClamping clamp); /* NZ to clamp XYZ to be +ve */ \
\
/* Measure the emissive refresh rate in Hz. */ \
/* (Available if cap2 & inst2_emis_refr_meas) */ \
/* Returns: */ \
/* inst_unsupported - if this instrument doesn't suport this measuremet */ \
/* or not in an emissive measurement mode */ \
/* inst_misread - if no refresh rate could be determined */ \
/* inst_ok - on returning a valid reading */ \
inst_code (*read_refrate)( \
struct _inst *p, \
double *ref_rate); /* Return the Hz */ \
\
/* Determine if a calibration is needed. Returns inst_calt_none if not */ \
/* or unknown, or a mask of the needed calibrations. */ \
/* This call checks if calibrations are invalid or have timed out. */ \
/* With the exception of instruments with automated calibration */ \
/* (ie. SpectroScan), an instrument will typically */ \
/* not check for calibration timout any other way. */ \
/* [What's returned is the same as get_n_a_cals() [ needed_calibrations.] */\
inst_cal_type (*needs_calibration)( \
struct _inst *p); \
\
/* Return combined mask of needed and available inst_cal_type's */ \
/* for the current mode. */ \
inst_code (*get_n_a_cals)( \
struct _inst *p, \
inst_cal_type *needed_calibrations, \
inst_cal_type *available_calibrations); \
\
/* Request an instrument calibration. */ \
/* This is use if the user decides they want to do a calibration */ \
/* in anticipation of a calibration (needs_calibration()) to avoid */ \
/* requiring one during measurement, or in response to measuring */ \
/* returning inst_needs_cal before retrying the measurement, */ \
/* or to do one or more re-calibrations. */ \
\
/* *calt should contain the mask of calibrations to be performed, */ \
/* with *calc set to the current calibration condition. */ \
/* Alternately, one of the psudo-calibration types inst_calt_all, */ \
/* inst_calt_needed or inst_calt_available can be used, */ \
/* and/or the *calc of inst_calc_none to get calibrate() */ \
/* to determine the required calibration types and conditions. */ \
/* (The corresponding calibration types will be used & returned. */ \
\
/* If no error is returned to the first call to calibrate() */ \
/* then the instrument was capable of calibrating without user or */ \
/* application intervention. If on the other hand calibrate() returns */ \
/* inst_cal_setup, then the appropriate action indicated by the value */ \
/* returned in *calc should be taken by the user or application, */ \
/* before retrying calibration() with the current setup indicated */ \
/* by *calc. If more than one calibration type is requested, then */ \
/* several retries may be needed with different calibration conditions. */ \
/* Each call to calibrate() will update *calt to reflect the remaining */ \
/* calibration to be performed. calibrate() returns inst_ok when no */ \
/* more calibrations remain. */ \
\
/* If the calc has the inst_calc_optional_flag flag set, */ \
/* then the user should be offered the option of skipping the */ \
/* calibration. If they decide to skip it, return a calc with */ \
/* inst_calc_optional_flag set, and if they want to proceed, */ \
/* make sure the inst_calc_optional_flag is cleared in the returned */ \
/* calc. */ \
\
/* DOESN'T use the trigger mode */ \
/* Return inst_unsupported if *calt is not appropriate, */ \
/* inst_cal_setup if *calc is not appropriate. */ \
inst_code (*calibrate)( \
struct _inst *p, \
inst_cal_type *calt, /* Calibration type to do/remaining */ \
inst_cal_cond *calc, /* Current condition/desired condition */ \
inst_calc_id_type *idtype, /* Condition identifier type */ \
char id[CALIDLEN]); /* Condition identifier (ie. white */ \
/* reference ID, filter ID, message string, */ \
/* etc.) */ \
\
/* Measure a display update, and instrument reaction time. It is */ \
/* assumed that a white to black change will be made to the */ \
/* displayed color during this call, and this is used to measure */ \
/* the time it took for the update to be noticed by the instrument, */ \
/* up to 1.0 second. */ \
/* The instrument reaction time accounts for the time between */ \
/* when the measure function is called and the samples actually being */ \
/* taken. This value may be negative if there is a filter delay. */ \
/* The method white_change() should be called with init=1 before */ \
/* calling meas_delay, and then with init=0 during the meas_delay() */ \
/* call to timestamp the transition. */ \
/* Note that a default instmsec will be returned even on error. */ \
inst_code (*meas_delay)( \
struct _inst *p, \
int *dispmsec, /* Return display update delay in msec */ \
int *instmsec); /* Return instrument reaction time in msec */ \
\
/* Call used by other thread to timestamp the patch transition. */ \
inst_code (*white_change)( \
struct _inst *p, \
int init); /* nz to init time stamp, z to mark transition */ \
\
/* Return the last calibrated refresh rate in Hz. Returns: */ \
/* (Available if cap2 & inst2_get_refresh_rate) */ \
/* inst_unsupported - if this instrument doesn't suport a refresh mode */ \
/* or is unable to retrieve the refresh rate */ \
/* inst_needs_cal - if the refresh rate value is not valid */ \
/* inst_misread - if no refresh rate could be determined */ \
/* inst_ok - on returning a valid reading */ \
inst_code (*get_refr_rate)( \
struct _inst *p, \
double *ref_rate); /* Return the Hz */ \
\
/* Set the calibrated refresh rate in Hz. */ \
/* (Available if cap2 & inst2_set_refresh_rate) */ \
/* Set refresh rate to 0.0 to mark it as invalid */ \
/* Rates outside the range 5.0 to 150.0 Hz will return an error */ \
/* Note that not all instruments that can return a refresh rate, */ \
/* will permit one to be set (ie., DTP92) */ \
inst_code (*set_refr_rate)( \
struct _inst *p, \
double ref_rate); /* Rate in Hz */ \
\
/* Insert a compensation filter in the instrument readings */ \
/* This is typically needed if an adapter is being used, that alters */ \
/* the spectrum of the light reaching the instrument */ \
/* Not fully implemented across all instrument types (spectrolino only ?) */ \
/* To remove the filter, pass NULL for the filter filename */ \
inst_code (*comp_filter)( \
struct _inst *p, \
char *filtername); /* File containing compensating filter */ \
\
/* Insert a colorimetric correction matrix in the instrument XYZ readings */ \
/* This is only valid for colorimetric instruments, and can only be */ \
/* applied over a base calibration display type. Setting a display */ \
/* type will clear the matrix. */ \
/* To clear the matrix, pass NULL for the matrix */ \
inst_code (*col_cor_mat)( \
struct _inst *p, \
disptech dtech, /* Use disptech_unknown if not known */ \
int cbid, /* Calibration display type base ID, needed 1 if unknown */\
double mtx[3][3]); /* XYZ matrix */ \
\
/* Use a Colorimeter Calibration Spectral Set (ccss) to set the */ \
/* instrumen calibration. This will affect emissive readings. */ \
/* An alternate observer may also be set, and this will affect both */ \
/* emissive and ambient readings. */ \
/* This is only valid for colorimetric instruments. */ \
/* To set calibration back to default, pass NULL for sets, and */ \
/* icxOT_default for the observer. */ \
inst_code (*col_cal_spec_set)( \
struct _inst *p, \
disptech dtech, /* Use disptech_unknown if not known */ \
xspect *sets, /* Set of sample spectra */ \
int no_sets); /* Number on set */ \
\
/* Supply a user interaction callback function. \
* This is called for one of three different purposes: \
* To signal that the instrument measurement has been triggered. \
* To poll for an abort while waiting to trigger. \
* To poll for a user abort during measurement. \
* \
* The callback function will have the purpose paramater appropriately. \
* \
* For inst_negcoms, the return value of inst_user_abort \
* will abort the communication negotiation. \
* \
* For inst_armed return value should be one of: \
* inst_ok to do nothing, inst_user_abort to abort the measurement, \
* or inst_user_trig to trigger the measurement. \
* \
* For inst_triggered, the return value of the callback is ignored. \
* \
* For inst_measuring the return value should be one of: \
* inst_ok to do nothing, inst_user_abort to abort the measurement. \
* \
* NULL can be set to disable the callback. \
*/ \
void (*set_uicallback)(struct _inst *p, \
inst_code (*uicallback)(void *cntx, inst_ui_purp purp), \
void *cntx); \
\
/* Supply an aynchronous event callback function. \
* This is called from a different thread with the following possible events: \
* \
* inst_event_switch: Instrument measure/calibrate switch pressed \
* inst_event_mconf: The measurement configuration has changed (ie. sensor position) \
* inst_event_scan_ready: Ready for manual strip scan (i.e. issue audible prompt) \
* \
* NULL can be set to disable the callback. \
*/ \
void (*set_event_callback)(struct _inst *p, \
void (*eventcallback)(void *cntx, inst_event_type event), \
void *cntx); \
\
/* Generic inst error codes interpretation */ \
char * (*inst_interp_error)(struct _inst *p, inst_code ec); \
\
/* Instrument specific error codes interpretation */ \
char * (*interp_error)(struct _inst *p, int ec); \
\
/* Convert instrument specific inst_wrong_config error to inst_config enum */ \
inst_config (*config_enum)(struct _inst *p, int ec); \
\
/* Return the last serial communication error code */ \
/* (This is used for deciding fallback/retry strategies) */ \
int (*last_scomerr)(struct _inst *p); \
\
/* Destroy ourselves */ \
void (*del)(struct _inst *p); \
/* The base object type */
struct _inst {
INST_OBJ_BASE
}; typedef struct _inst inst;
/* Virtual constructor. */
/* Return NULL for unknown instrument, */
/* or serial instrument if nocoms == 0. */
/* (Doesn't copy icompaths log!) */
/* If uicallback is provided, it will be set in the resulting inst */
extern inst *new_inst(
icompath *path, /* Device path this instrument */
int nocoms, /* Don't open if communications are needed to establish inst type */
a1log *log, /* Log to use */
inst_code (*uicallback)(void *cntx, inst_ui_purp purp), /* optional uicallback */
void *cntx /* Context for callback */
);
/* - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - */
/* Implementation functions used by instrument drivers */
/* (Client code should not call these) */
/* Get a status or set or get an option (default implementation) */
inst_code inst_get_set_opt_def(
inst *p,
inst_opt_type m, /* Option type */
va_list args); /* Option parameters */
/* - - - - - - - - - - - - - - - - - - -- */
/* Create the display type list */
inst_code inst_creat_disptype_list(inst *p,
int *pndtlist, /* Number in returned list */
inst_disptypesel **pdtlist, /* Returned list */
inst_disptypesel *sdtlist, /* Static list */
int doccss, /* Add installed ccss files */
int doccmx /* Add matching installed ccmx files */
);
/* Free a display type list */
void inst_del_disptype_list(inst_disptypesel *list, int no);
/* - - - - - - - - - - - - - - - - - - -- */
/* Issue an inst_event_scan_ready event after a delay */
void issue_scan_ready(inst *p, int delay);
/* - - - - - - - - - - - - - - - - - - -- */
/* CCMX support - ccmx instrument proxy */
typedef struct {
char *path; /* Path to the file */
char *desc; /* Technology + display description */
disptech dtech; /* Display Technology enumeration (optional if disp) */
int cc_cbid; /* Calibration display type base ID required */
int refr; /* Refresh mode flag */
char *sel; /* UI selector characters (may be NULL) */
int oem; /* nz if oem origin */
double mat[3][3]; /* The matrix values */
} iccmx;
/* return a list of installed ccmx files. */
/* if itype != instUnknown, return those that match the given instrument. */
/* The list is sorted by description and terminated by a NULL entry. */
/* If no is != NULL, return the number in the list */
/* Return NULL and -1 if there is a malloc error */
iccmx *list_iccmx(instType itype, int *no);
/* Free up a iccmx list */
void free_iccmx(iccmx *list);
/* - - - - - - - - - - - - - - - - - - -- */
/* CCSS support - ccss instrument proxy */
typedef struct {
char *path; /* Path to the file */
char *desc; /* Technology + display description */
disptech dtech; /* Display Technology enumeration (optional if disp) */
int refr; /* Refresh mode flag */
char *sel; /* UI selector characters (may be NULL) */
int oem; /* nz if oem origin */
xspect *sets; /* Set of sample spectra */
int no_sets; /* Number on set */
} iccss;
/* return a list of installed ccss files. */
/* The list is sorted by description and terminated by a NULL entry. */
/* If no is != NULL, return the number in the list */
/* Return NULL and -1 if there is a malloc error */
iccss *list_iccss(int *no);
/* Free up a iccss list */
void free_iccss(iccss *list);
/* - - - - - - - - - - - - - - - - - - -- */
#ifdef __cplusplus
}
#endif
#define INST_H
#endif /* INST_H */
|