@@ -0,0 +1,1083 @@
+--/************************************************************************
+--* *
+--* Copyright (c) 1998-2004 Intel Corporation. All Rights Reserved. *
+--* *
+--* Redistribution and use in source and binary forms, with or without *
+--* modification, are permitted provided that the following conditions *
+--* are met: *
+--* *
+--* a.. Redistributions of source code must retain the above copyright *
+--* notice, this list of conditions and the following disclaimer. *
+--* b.. Redistributions in binary form must reproduce the above *
+--* copyright notice, this list of conditions and the following *
+--* disclaimer in the documentation and/or other materials provided *
+--* with the distribution. *
+--* c.. Neither the name of Intel Corporation nor the names of its *
+--* contributors may be used to endorse or promote products derived *
+--* from this software without specific prior written permission. *
+--* *
+--* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS *
+--* "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT *
+--* LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR *
+--* A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT *
+--* OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, *
+--* SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT *
+--* LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, *
+--* DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON *
+--* ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR *
+--* TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF *
+--* THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH *
+--* DAMAGE. *
+--* *
+--*************************************************************************
+--* Name : PetEvents.mib
+--* Description : MIB file for PET events
+--* Created : Wesdnesday, December 17, 2003
+--* Author : Intel Corporation
+--*
+--* $History:$
+--*
+--* Date : March 7th,2002
+--* Changed by :
+--* Change Description : Updated MIB file
+--*
+--* Date : December 17th,2003
+--* Changed by :
+--* Change Description : Started with ASF MIB file
+--*
+--*************************************************************************/
+
+
+
+PET-EVENTS DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ enterprises
+ FROM RFC1155-SMI
+ OBJECT-TYPE
+ FROM RFC-1212
+
+ TRAP-TYPE
+ FROM RFC-1215
+
+
+ DisplayString
+ FROM RFC1213-MIB;
+
+ wiredformgmt OBJECT IDENTIFIER ::= { enterprises 3183 }
+ pet OBJECT IDENTIFIER ::= { wiredformgmt 1 }
+
+-- MODULE IDENTIFICATION
+--
+-- PET Events Alerting MODULE-IDENTITY
+-- LAST-UPDATED "February 4, 2004"
+-- ORGANIZATION "Intel Corporation"
+-- CONTACT-INFO
+-- " PET Events,
+-- Intel Corporation, DP3-407
+-- DuPont, WA 98352"
+-- DESCRIPTION
+-- "This is the MIB file for SNMPv1.0 based PET traps"
+
+
+-- ****************************************
+-- SYSTEM INFORMATION BRANCH STARTS HERE.
+-- ****************************************
+
+ petevts OBJECT IDENTIFIER ::= { pet 1 }
+
+
+-- **********************************************
+-- * Temperature *
+-- **********************************************
+
+-- Lower Non Critical threshold crossed
+ trapUnderTemperatureWarning TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Under-Temperature Warning (Lower non-critical, going low)"
+
+ --#TYPE "Temperature Event"
+ --#SUMMARY "Under-Temperature Warning (Lower non-critical, going low)"
+ --#ARGUMENTS {}
+ --#SEVERITY WARNING
+
+ ::= 65792
+
+-- Lower Critical threshold crossed
+ trapUnderTemperatureCritical TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Critical Under-Temperature Problem (Lower Critical - going low)"
+
+ --#TYPE "Temperature Event"
+ --#SUMMARY "Critical Under-Temperature Problem (Lower Critical - going low)"
+ --#ARGUMENTS {}
+ --#SEVERITY CRITICAL
+
+ ::= 65794
+
+-- Upper Non Critical threshold crossed
+ trapOverTemperatureWarning TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Over-Temperature Warning (Upper non-critical, going high)"
+
+ --#TYPE "Temperature Event"
+ --#SUMMARY "Over-Temperature Warning (Upper non-critical, going high)"
+ --#ARGUMENTS {}
+ --#SEVERITY WARNING
+
+ ::= 65799
+
+-- Upper Critical threshold crossed
+ trapOverTemperatureCritical TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Critical Over-Temperature Problem (Upper Critical - going high)"
+
+ --#TYPE "Temperature Event"
+ --#SUMMARY "Critical Over-Temperature Problem (Upper Critical - going high)"
+ --#ARGUMENTS {}
+ --#SEVERITY CRITICAL
+
+ ::= 65801
+
+-- Back to Normal from Lower Non Critical
+ trapUnderTemperatureWarningCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Under-Temperature Warning Cleared"
+
+ --#TYPE "Temperature Event"
+ --#SUMMARY "Under-Temperature Warning Cleared"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 65920
+
+-- Back to Normal from Lower Critical
+ trapUnderTemperatureCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Under-Temperature Problem Cleared"
+
+ --#TYPE "Temperature Event"
+ --#SUMMARY "Under-Temperature Problem Cleared"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 65922
+
+-- Back to Normal from Upper Non Critical
+ trapOverTemperatureWarningCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Over-Temperature warning Cleared"
+
+ --#TYPE "Temperature Event"
+ --#SUMMARY "Over-Temperature Warning Cleared"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 65927
+
+-- Back to Normal from Upper Critical
+ trapOverTemperatureCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Over-Temperature Problem Cleared"
+
+ --#TYPE "Temperature Event"
+ --#SUMMARY "Over-Temperature Problem Cleared"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 65929
+
+-- Generic critical temperature problem
+ trapGenericCriticalTemperature TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Generic Critical Temperature Problem (Transition to Critical from less severe)"
+
+ --#TYPE "Temperature Event"
+ --#SUMMARY "Generic Critical Temperature Problem (Transition to Critical from less severe)"
+ --#ARGUMENTS {}
+ --#SEVERITY CRITICAL
+
+ ::= 67330
+
+-- Generic temperature warning
+ trapGenericTemperatureWarning TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Generic Temperature Warning (Transition to Warning from less severe)"
+
+--#TYPE "Temperature Event"
+--#SUMMARY "Generic Temperature Warning (Transition to Warning from less severe)"
+--#ARGUMENTS {}
+--#SEVERITY WARNING
+
+ ::= 67331
+
+
+-- **********************************************
+-- * Voltage *
+-- **********************************************
+
+-- (Analog voltage) Lower Non Critical threshold crossed
+ trapUnderAnalogVoltageWarning TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Under-Voltage Warning (Lower Non Critical - going low)"
+--#TYPE "Voltage Event"
+--#SUMMARY "Under-Voltage Warning (Lower Non Critical - going low)"
+--#ARGUMENTS {}
+--#SEVERITY WARNING
+
+ ::= 131328
+
+-- (Analog voltage) Lower Critical threshold crossed
+ trapUnderAnalogVoltageCritical TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Critical Under-Voltage Problem (Lower Critical - going low)"
+
+--#TYPE "Voltage Event"
+--#SUMMARY "Critical Under-Voltage Problem (Lower Critical - going low)"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 131330
+
+-- (Analog voltage) Upper Non Critical threshold crossed
+ trapOverAnalogVoltageWarning TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Over-Voltage Warning (Upper Non Critical - going high)"
+
+--#TYPE "Voltage Event"
+--#SUMMARY "Over-Voltage Warning (Upper Non Critical - going high)"
+--#ARGUMENTS {}
+--#SEVERITY WARNING
+
+ ::= 131335
+
+-- (Analog voltage) Upper Critical threshold crossed
+ trapOverAnalogVoltageCritical TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Critical Over-Voltage Problem (Upper Critical - going high)"
+
+--#TYPE "Voltage Event"
+--#SUMMARY "Critical Over-Voltage Problem (Upper Critical - going high)"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 131337
+
+-- (Analog voltage) Voltage back to OK from Lower Non Critical
+ trapUnderAnalogVoltageWarningCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Under-Voltage Warning Cleared"
+
+--#TYPE "Voltage Event"
+--#SUMMARY "Under-Voltage Warning Cleared"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 131456
+
+-- (Analog voltage) Voltage back to OK from Lower Non Critical
+ trapUnderAnalogVoltageCriticalCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Under-Voltage Problem Cleared"
+
+--#TYPE "Voltage Event"
+--#SUMMARY "Under-Voltage Problem Cleared"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 131458
+
+-- (Analog voltage) Voltage back to OK from Upper Non Critical Warning
+ trapOverAnalogVoltageWarningCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Over-Voltage Warning Cleared"
+
+--#TYPE "Voltage Event"
+--#SUMMARY "Over-Voltage Warning Cleared"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 131463
+
+-- (Analog voltage) Voltage back to OK from Upper Critical
+ trapOverAnalogVoltageCriticalCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Over-Voltage Problem Cleared"
+
+--#TYPE "Voltage Event"
+--#SUMMARY "Over-Voltage Problem Cleared"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 131465
+
+-- (Discrete voltage) Critical voltage problem
+ trapGenericCriticalDiscreteVoltageCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Generic Critical Voltage Problem Cleared"
+
+--#TYPE "Voltage Event"
+--#SUMMARY "Generic Critical Voltage Problem Cleared"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 131840
+
+-- (Discrete voltage) Critical voltage problem
+ trapGenericCriticalDiscreteVoltage TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Generic Critical Voltage Problem (Transition to Critical from less severe)"
+
+--#TYPE "Voltage Event"
+--#SUMMARY "Generic Critical Voltage Problem (Transition to Critical from less severe)"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 131841
+
+-- (Discrete voltage) Critical voltage problem
+ trapGenericCriticalDiscreteVoltage2 TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Generic Critical Voltage Problem (Transition to Critical from less severe)"
+
+--#TYPE "Voltage Event"
+--#SUMMARY "Generic Critical Voltage Problem (Transition to Critical from less severe)"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 132866
+
+-- (Discrete voltage) Non-Critical voltage problem
+ trapGenericDiscreteVoltageWarning TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Generic Voltage Warning (Transition to Non-Critical from less severe)"
+
+--#TYPE "Voltage Event"
+--#SUMMARY "Generic Voltage Warning (Transition to Non-Critical from less severe)"
+--#ARGUMENTS {}
+--#SEVERITY WARNING
+
+ ::= 132867
+
+
+-- **********************************************
+-- * Fan *
+-- **********************************************
+
+-- Lower Non Critical threshold crossed
+ trapFanUnderSpeedWarning TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Fan speed warning (Fan speed below expected speed)"
+
+--#TYPE "Fan Event"
+--#SUMMARY "Fan speed Warning (Fan speed below expected speed)"
+--#ARGUMENTS {}
+--#SEVERITY WARNING
+
+ ::= 262400
+
+-- Fan Lower Critical threshold crossed
+ trapFanCriticalUnderSpeed TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Generic Critical Fan Failure (Transition to Critical from less severe)"
+
+--#TYPE "Fan Event"
+--#SUMMARY "Critical Fan Failure (Transition to Critical from less severe)"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 262402
+
+-- Fan back to OK from warning level
+ trapFanUnderSpeedWarningCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Fan speed Warning Cleared"
+
+--#TYPE "Fan Event"
+--#SUMMARY "Fan speed Warning Cleared"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 262528
+
+-- Fan back to OK from critical level
+ trapFanCriticalUnderSpeedCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Critical Fan Failure Cleared"
+
+--#TYPE "Fan Event"
+--#SUMMARY "Critical Fan Failure Cleared"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 262530
+
+-- Fan Full Redundancy
+ trapFanFullRedundancy TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Fan redundancy has returned to Normal"
+
+--#TYPE "Fan Event"
+--#SUMMARY "Fan redundancy has returned to Normal"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 264960
+
+-- Fan Redundancy lost
+ trapFanRedundancyLost TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Fan Redundancy has been Lost"
+
+--#TYPE "Fan Event"
+--#SUMMARY "Fan Redundancy has been Lost"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 264961
+
+-- Fan Redundancy degraded
+ trapFanRedundancyDegraded TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Fan Redundancy is in a degraded state"
+
+--#TYPE "Fan Event"
+--#SUMMARY "Fan Redundancy is in a degraded state"
+--#ARGUMENTS {}
+--#SEVERITY WARNING
+
+ ::= 264962
+
+
+-- **********************************************
+-- * Power Supply *
+-- **********************************************
+
+-- Power Supply Full Redundancy
+ trapPowerSupplyFullRedundancy TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Power Supply Redundancy Has Returned to Normal"
+
+--#TYPE "Power Supply Event"
+--#SUMMARY "Power Supply Redundancy Has Returned to Normal"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 527104
+
+-- Power Supply Redundancy lost
+ trapPowerSupplyRedundancyLost TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Power Supply Redundancy has been Lost"
+
+--#TYPE "Power Supply Event"
+--#SUMMARY "Power Supply Redundancy has been Lost"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 527105
+
+-- Power Supply Redundancy degraded
+ trapPowerSupplyRedundancyDegraded TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Power Supply Redundancy is in a degraded state"
+
+--#TYPE "Power Supply Event"
+--#SUMMARY "Power Supply Redundancy is in a degraded state"
+--#ARGUMENTS {}
+--#SEVERITY WARNING
+
+ ::= 527106
+
+-- Power Supply presence detected
+ trapPowerSupplyPresenceDeteced TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Power Supply Inserted"
+
+--#TYPE "Power Supply Event"
+--#SUMMARY "Power Supply Inserted"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 552704
+
+trapPowerSupplyFailureDetected TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Power supply Failure detected"
+
+--#TYPE "Power Supply Event"
+--#SUMMARY "Power Supply failure detected"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 552705
+
+trapPowerSupplyWarning TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Power supply Warning"
+
+--#TYPE "Power Supply Event"
+--#SUMMARY "Power Supply Warning"
+--#ARGUMENTS {}
+--#SEVERITY WARNING
+
+ ::= 552706
+
+ -- AC Lost
+ trapPowerSupplyACLost TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Power Supply AC Lost"
+
+--#TYPE "Power Supply Event"
+--#SUMMARY "Power Supply AC Lost"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 552707
+
+-- Power Supply removed
+ trapPowerSupplyPresenceRemoved TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Power Supply Removed"
+
+--#TYPE "Power Supply Event"
+--#SUMMARY "Power Supply Removed"
+--#ARGUMENTS {}
+--#SEVERITY WARNING
+
+ ::= 552832
+
+-- Back to normal from failure
+ trapPowerSupplyFailureCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Power Supply Failure Cleared"
+
+--#TYPE "Power Supply Event"
+--#SUMMARY "Power Supply Failure Cleared"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 552833
+
+-- Predictive Failure cleared
+ trapPowerSupplyWarningCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Power Supply Warning Cleared"
+
+--#TYPE "Power Supply Event"
+--#SUMMARY "Power Supply Warning Cleared"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 552834
+
+ -- AC Back
+ trapPowerSupplyACBack TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Power Supply AC Restored"
+
+--#TYPE "Power Supply Event"
+--#SUMMARY "Power Supply AC Restored"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 552835
+
+-- Power Unit Redundancy OK
+ trapPowerUnitRedundancyOk TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Power Unit Redundancy has been restored"
+
+--#TYPE "Power Supply Event"
+--#SUMMARY "Power Unit Redundancy has been restored"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 592640
+
+-- Power Unit Redundancy lost
+ trapPowerUnitRedundancyLost TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Power Unit Redundancy has been Lost"
+
+--#TYPE "Power Supply Event"
+--#SUMMARY "Power Unit Redundancy has been Lost"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 592641
+
+-- **********************************************
+-- * Processor *
+-- **********************************************
+
+-- Processor internal error
+ trapProcessorInternalError TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Processor Internal Error"
+
+--#TYPE "Processor Event"
+--#SUMMARY "Processor Internal Error"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 487168
+
+-- Processor Thermal Trip
+ trapProcessorThermalTrip TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Processor Thermal Trip (Over Temperature Shutdown)"
+
+--#TYPE "Processor Event"
+--#SUMMARY "Processor Thermal Trip (Over Temperature Shutdown)"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 487169
+
+-- Processor Fault Resilient Booting (FRB) 1 / Built-in self test (BIST) Error
+ trapProcessorBistError TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Processor Fault Resilient Booting (FRB) 1 / BIST (Built In Self Test) Failure"
+
+--#TYPE "Processor Event"
+--#SUMMARY "Processor Fault Resilient Booting (FRB) 1 / Processor BIST (Built In Self Test) Failure"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 487170
+
+-- Processor Fault Resilient Booting (FRB) 2 / Hang in Power On Self Test (POST)
+trapProcessorFRB2Failure TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Processor Fault Resilient Booting (FRB) 2 / Hang in Power On Self Test (POST) Failure"
+
+--#TYPE "Processor Event"
+--#SUMMARY "Processor Fault Resilient Booting (FRB) 2 / Hang in Power On Self Test (POST) Failure"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 487171
+
+-- Processor Fault Resilient Booting (FRB) 3 / Processor Setup / Initialization Failure
+trapProcessorFRB3Failure TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Processor Fault Resilient Booting (FRB) 3 / Processor Setup / Initialization Failure"
+
+--#TYPE "Processor Event"
+--#SUMMARY "Processor Fault Resilient Booting (FRB) 3 / Processor Setup / Initialization Failure"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 487172
+
+-- Processor config error
+ trapProcessorConfigError TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Processor Configuration Error"
+
+--#TYPE "Processor Event"
+--#SUMMARY "Processor Configuration Error"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 487173
+
+-- Processor throttle.
+ trapProcessorThrottle TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Processor Throttled (Processor Speed Reduced)"
+
+--#TYPE "Processor Event"
+--#SUMMARY "Processor Throttled (Processor Speed Reduced)"
+--#ARGUMENTS {}
+--#SEVERITY WARNING
+
+ ::= 487178
+
+-- Processor internal error cleared
+ trapProcessorInternalErrorCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Processor Internal Error Cleared"
+
+--#TYPE "Processor Event"
+--#SUMMARY "Processor Internal Error Cleared"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 487296
+
+-- Processor Back to normal from Thermal Trip
+ trapProcessorThermalTripCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Processor Thermal Trip (Over Temperature Shutdown) Cleared"
+
+--#TYPE "Processor Event"
+--#SUMMARY "Processor Thermal Trip (Over Temperature Shutdown) Cleared"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 487297
+
+-- Processor BIST Error cleared
+ trapProcessorBistErrorCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Processor BIST (Built In Self Test) Failure Cleared"
+
+--#TYPE "Processor Event"
+--#SUMMARY "Processor BIST (Built In Self Test) Failure Cleared"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 487298
+
+-- Processor config error cleared
+ trapProcessorConfigErrorCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Processor Configuration Error Cleared"
+
+--#TYPE "Processor Event"
+--#SUMMARY "Processor Configuration Error Cleared"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 487301
+
+-- Processor return to normal from throttled
+ trapProcessorThrottleCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Processor Throttle Cleared (Normal Processor Speed)"
+
+--#TYPE "Processor Event"
+--#SUMMARY "Processor Throttle Cleared (Normal Processor Speed)"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 487306
+
+-- **********************************************
+-- * Memory *
+-- **********************************************
+
+trapMemoryUncorrectableECC TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Uncorrectable ECC or other uncorrectable memory error"
+
+--#TYPE "Memory Event"
+--#SUMMARY "Uncorrectable ECC or other uncorrectable memory error"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 814849
+
+
+--**********************
+--* Chassis Intrusion *
+--**********************
+
+-- Chassis Intrusion
+ trapChassisIntrusion TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Chassis Intrusion - Physical Security Violation"
+
+--#TYPE "Chassis Intrusion Event"
+--#SUMMARY "Chassis Intrusion - Physical Security Violation"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 356096
+
+-- Chassis Intrusion cleared
+ trapChassisIntrusionCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Chassis Intrusion (Physical Security Violation) Event Cleared"
+
+--#TYPE "Chassis Intrusion Event"
+--#SUMMARY "Chassis Intrusion( Physical Security Violation) Event Cleared"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 356224
+
+
+-- **********************************************
+-- * Critical Interrupts *
+-- **********************************************
+
+-- Critical Interrupt, Bus timeout error
+trapCriticalInterruptBusTimeout TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Critical Interrupt, Bus Timeout error"
+
+--#TYPE "Critical Interrupts Event"
+--#SUMMARY "Critical Interrupt, Bus Timeout error"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 1273601
+
+-- Critical Interrupt, IO Channel Non-Maskable Interrupt
+trapCriticalInterruptIOChannelNMI TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Critical Interrupt, IO Channel check NMI error"
+
+--#TYPE "Critical Interrupts Event"
+--#SUMMARY "Critical Interrupt, IO Channel check NMI error"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 1273602
+
+-- Critical Interrupt, Software Non-Maskable Interrupt error
+trapCriticalInterruptSoftwareNMI TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Critical Interrupt, software NMI error"
+
+--#TYPE "Critical Interrupts Event"
+--#SUMMARY "Critical Interrupt, software NMI error"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 1273603
+
+-- Non special-cycle parity errors
+trapCriticalInterruptPCIPERR TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Critical Interrupt, PCI PERR parity error"
+
+--#TYPE "Critical Interrupts Event"
+--#SUMMARY "Critical Interrupt, PCI PERR parity error"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 1273604
+
+-- Special-cycle parity errors
+trapCriticalInterruptPCISERR TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Critical Interrupt, PCI SERR parity error"
+
+--#TYPE "Critical Interrupts Event"
+--#SUMMARY "Critical Interrupt, PCI SERR parity error"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 1273605
+
+-- Bus uncorrectable error
+trapCriticalInterruptBusUncorrect TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Critical Interrupt, Bus Uncorrectable error"
+
+--#TYPE "Critical Interrupts Event"
+--#SUMMARY "Critical Interrupt, Bus Uncorrectable error"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 1273608
+
+-- Fatal non-maskable interrupt (NMI)
+trapCriticalInterruptFatalNMI TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Critical Interrupt, Fatal NMI error"
+
+--#TYPE "Critical Interrupts Event"
+--#SUMMARY "Critical Interrupt, Fatal NMI error"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 1273609
+
+
+-- **********************************************
+-- * System Firmware Progress *
+-- **********************************************
+
+-- Power On Self Test (POST) code error
+trapBIOSPOSTCodeError TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "System Firmware Progress: BIOS POST code error"
+
+--#TYPE "System Firmware Progress Event"
+--#SUMMARY "System Firmware Progress: BIOS POST code error"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 1011456
+
+
+-- **********************************************
+-- * WatchDog *
+-- **********************************************
+
+-- Watchdog reset event
+trapWatchdogReset TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Watchdog Reset"
+
+--#TYPE "Watchdog Event"
+--#SUMMARY "Watchdog Reset"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 2322177
+
+-- Watchdog power down event
+trapWatchdogPowerDown TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Watchdog Power Down"
+
+--#TYPE "Watchdog Event"
+--#SUMMARY "Watchdog Power Down"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 2322178
+
+-- Watchdog power cycle event
+trapWatchdogPowerCycle TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "Watchdog Power Cycle"
+
+--#TYPE "Watchdog Event"
+--#SUMMARY "Watchdog Power cycle"
+--#ARGUMENTS {}
+--#SEVERITY WARNING
+
+ ::= 2322179
+
+
+-- **********************************************
+-- * System Event Log *
+-- **********************************************
+
+-- System Event Log Cleared
+ trapSystemEventLogCleared TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "System Event Log (SEL) Cleared"
+
+--#TYPE "System Event Log"
+--#SUMMARY "System Event Log (SEL) Cleared"
+--#ARGUMENTS {}
+--#SEVERITY INFORMATIONAL
+
+ ::= 1076994
+
+-- System Event Log Full
+ trapSystemEventLogFull TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "System Event Log (SEL) Full (Logging Disabled)"
+
+--#TYPE "System Event Log"
+--#SUMMARY "System Event Log (SEL) Full (Logging Disabled)"
+--#ARGUMENTS {}
+--#SEVERITY CRITICAL
+
+ ::= 1076995
+
+
+-- **********************************************
+-- * System *
+-- **********************************************
+
+-- System boot event
+trapSystemBootEvent TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "System Boot Event"
+
+--#TYPE "System Event"
+--#SUMMARY "System Boot Event"
+--#ARGUMENTS {}
+--#SEVERITY WARNING
+
+ ::= 1208065
+
+-- **********************************************
+-- * Linux Panic, Critical Stop *
+-- **********************************************
+
+-- Linux panic event
+trapOSCriticalStop TRAP-TYPE
+ ENTERPRISE petevts
+ DESCRIPTION
+ "OS Critical Stop occurred"
+
+--#TYPE "System Event"
+--#SUMMARY "System Boot Event"
+--#ARGUMENTS {}
+--#SEVERITY WARNING
+
+ ::= 2125569
+
+END