diff options
author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-07-06 18:04:32 +0200 |
---|---|---|
committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-07-06 18:04:32 +0200 |
commit | a7f89980e5b3f4b9a74c70dbc5ffe8aabd28be28 (patch) | |
tree | 41c4deec1fdfbafd7821b4ca7a9772ac0abd92f5 /doc/iekanalyzer.8 |
Imported Upstream version 2.9.3upstream/2.9.3
Diffstat (limited to 'doc/iekanalyzer.8')
-rw-r--r-- | doc/iekanalyzer.8 | 251 |
1 files changed, 251 insertions, 0 deletions
diff --git a/doc/iekanalyzer.8 b/doc/iekanalyzer.8 new file mode 100644 index 0000000..c4ca1e2 --- /dev/null +++ b/doc/iekanalyzer.8 @@ -0,0 +1,251 @@ +.TH IEKANALYZER 8 "Version 1.0: 09 Sep 2010" +.SH NAME +ipmiutil_ekanalyzer \- run FRU-Ekeying analyzer with FRU files +.SH SYNOPSIS +.B "ipmiutil ekanalyzer [-mx -NPRUEFJTVY] commands" +.B (deprecated, see ifru instead) + +.SH DESCRIPTION +.I ipmiutil ekanalyzer +is a program that analyzes FRU Ekeying information from files +saved from PICMG IPMI systems. + +.br +\fIekanalyzer\fP \fBcommand\fR \fBxx=filename1\fR \fBxx=filename2\fR [\fBrc=filename3\fR] +.br +NOTE: This command can support a maximum of 8 files per command line + +.IP "\fIfilename1\fP" +binary file that stores FRU data of a Carrier or an AMC module + +.IP "\fIfilename2\fP" +binary file that stores FRU data of an AMC module. +These binary files can be generated from this command: + \fIipmiutil fru \-i id \-d filename\fP + +.IP "\fIfilename3\fP" +configuration file used for configuring On-Carrier Device ID or OEM GUID. This file is optional. + +.IP "\fIxx\fP" +indicates the type of the file. It can take the following value: +.br + \fIoc\fP : On-Carrier device +.br + \fIa1\fP : AMC slot A1 +.br + \fIa2\fP : AMC slot A2 +.br + \fIa3\fP : AMC slot A3 +.br + \fIa4\fP : AMC slot A4 +.br + \fIb1\fP : AMC slot B1 +.br + \fIb2\fP : AMC slot B2 +.br + \fIb3\fP : AMC slot B3 +.br + \fIb4\fP : AMC slot B4 +.br + \fIsm\fP : Shelf Manager + + +.SH OPTIONS + +.IP "-m 002000" +Show FRU for a specific MC (e.g. bus 00, sa 20, lun 00). +This could be used for PICMG or ATCA blade systems. +The trailing character, if present, indicates SMI addressing if 's', +or IPMB addressing if 'i' or not present. +.IP "-x" +Causes extra debug messages to be displayed. +.IP "-N nodename" +Nodename or IP address of the remote target system. If a nodename is +specified, IPMI LAN interface is used. Otherwise the local system +management interface is used. +.IP "-P/-R rmt_pswd" +Remote password for the nodename given. The default is a null password. +.IP "-U rmt_user" +Remote username for the nodename given. The default is a null username. +.IP "-E" +Use the remote password from Environment variable IPMI_PASSWORD. +.IP "-F drv_t" +Force the driver type to one of the followng: +imb, va, open, gnu, landesk, lan, lan2, lan2i, kcs, smb. +Note that lan2i means lan2 with intelplus. +The default is to detect any available driver type and use it. +.IP "-J" +Use the specified LanPlus cipher suite (0 thru 17): 0=none/none/none, +1=sha1/none/none, 2=sha1/sha1/none, 3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, +5=sha1/sha1/xrc4_40, 6=md5/none/none, ... 14=md5/md5/xrc4_40. +Default is 3. +.IP "-T" +Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2, 2=MD5, 4=Straight Password, 5=OEM. +.IP "-V" +Use a specified IPMI LAN privilege level. 1=Callback level, 2=User level, 3=Operator level, 4=Administrator level (default), 5=OEM level. +.IP "-Y" +Yes, do prompt the user for the IPMI LAN remote password. +Alternatives for the password are \-E or \-P. + +.SH "COMMANDS" +.RE +.TP +.br +The available commands for ekanalyzer are: + +.RE +.RS +.TP +\fIprint\fP [\fBcarrier\fR | \fBpower\fR | \fBall\fR] +.RS +.TP +\fIcarrier\fP (default) \fBoc=filename1\fR \fBoc=filename2\fR \fB...\fR +.br + +Display point to point physical connectivity between carriers and AMC modules. + Example: + # ipmiutil ekanalyzer print carrier oc=fru oc=carrierfru + From Carrier file: fru + Number of AMC bays supported by Carrier: 2 + AMC slot B1 topology: + Port 0 =====> On Carrier Device ID 0, Port 16 + Port 1 =====> On Carrier Device ID 0, Port 12 + Port 2 =====> AMC slot B2, Port 2 + AMC slot B2 topology: + Port 0 =====> On Carrier Device ID 0, Port 3 + Port 2 =====> AMC slot B1, Port 2 + *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-* + From Carrier file: carrierfru + On Carrier Device ID 0 topology: + Port 0 =====> AMC slot B1, Port 4 + Port 1 =====> AMC slot B1, Port 5 + Port 2 =====> AMC slot B2, Port 6 + Port 3 =====> AMC slot B2, Port 7 + AMC slot B1 topology: + Port 0 =====> AMC slot B2, Port 0 + AMC slot B1 topology: + Port 1 =====> AMC slot B2, Port 1 + Number of AMC bays supported by Carrier: 2 + +.TP +\fIpower\fP \fBxx=filename1\fR \fBxx=filename2\fR \fB...\fr +.br + +Display power supply information between carrier and AMC modules. +.TP +\fIall\fP \fBxx=filename\fR \fBxx=filename\fR \fB...\fr +.br + +Display both physical connectivity and power supply of each carrier and AMC +modules. + +.RE +.TP +\fIfrushow\fP \fBxx=filename\fR +.br +Convert a binary FRU file into human readable text format. Use \-v option to get +more display information. + +.RE +.RS +.TP +\fIsummary\fP [\fBmatch\fR | \fBunmatch\fR | \fBall\fR] +.RS +.TP +\fImatch\fP (default) \fBxx=filename\fR \fBxx=filename\fR \fB...\fR +.br +Display only matched results of Ekeying match between an On-Carrier device +and an AMC module or between 2 AMC modules. Example: + # ipmiutil ekanalyzer summary match oc=fru b1=amcB1 a2=amcA2 + On-Carrier Device vs AMC slot B1 + AMC slot B1 port 0 ==> On-Carrier Device 0 port 16 + Matching Result + From On-Carrier Device ID 0 + Channel ID 11 || Lane 0: enable + Link Type: AMC.2 Ethernet + Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link + Link Group ID: 0 || Link Asym. Match: exact match + To AMC slot B1 + Channel ID 0 || Lane 0: enable + Link Type: AMC.2 Ethernet + Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link + Link Group ID: 0 || Link Asym. Match: exact match + *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-* + AMC slot B1 port 1 ==> On-Carrier Device 0 port 12 + Matching Result + From On-Carrier Device ID 0 + Channel ID 6 || Lane 0: enable + Link Type: AMC.2 Ethernet + Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link + Link Group ID: 0 || Link Asym. Match: exact match + To AMC slot B1 + Channel ID 1 || Lane 0: enable + Link Type: AMC.2 Ethernet + Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link + Link Group ID: 0 || Link Asym. Match: exact match + *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-* + On-Carrier Device vs AMC slot A2 + AMC slot A2 port 0 ==> On-Carrier Device 0 port 3 + Matching Result + From On-Carrier Device ID 0 + Channel ID 9 || Lane 0: enable + Link Type: AMC.2 Ethernet + Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link + Link Group ID: 0 || Link Asym. Match: exact match + To AMC slot A2 + Channel ID 0 || Lane 0: enable + Link Type: AMC.2 Ethernet + Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link + Link Group ID: 0 || Link Asym. Match: exact match + *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-* + AMC slot B1 vs AMC slot A2 + AMC slot A2 port 2 ==> AMC slot B1 port 2 + Matching Result + From AMC slot B1 + Channel ID 2 || Lane 0: enable + Link Type: AMC.3 Storage + Link Type extension: Serial Attached SCSI (SAS/SATA) + Link Group ID: 0 || Link Asym. Match: FC or SAS interface {exact match} + To AMC slot A2 + Channel ID 2 || Lane 0: enable + Link Type: AMC.3 Storage + Link Type extension: Serial Attached SCSI (SAS/SATA) + Link Group ID: 0 || Link Asym. Match: FC or SAS interface {exact match} + *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-* +.TP +\fIunmatch\fP \fBxx=filename\fR \fBxx=filename\fR \fB...\fr +.br + +Display the unmatched results of Ekeying match between an On-Carrier device +and an AMC module or between 2 AMC modules +.TP +\fIall\fP \fBxx=filename\fR \fBxx=filename\fR \fB...\fr +.br + +Display both matched result and unmatched results of Ekeying match between two +cards or two modules. +.RE + +.SH "SEE ALSO" +ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8) ifirewall(8) +ifru(8) ifruset(8) ifwum(8) igetevent(8) ihealth(8) ihpm(8) +ilan(8) ipicmg(8) ireset(8) isel(8) isensor(8) iserial(8) isol(8) isunoem(8) +iwdt(8) ipmiutil(8) ipmi_port(8) + +.SH WARNINGS +See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil and any bug fix list. + +.SH COPYRIGHT +Copyright (C) 2009 Kontron America, Inc. +.PP +See the file COPYING in the distribution for more details +regarding redistribution. +.PP +This utility is distributed in the hope that it will be useful, but +WITHOUT ANY WARRANTY. + +.SH AUTHOR +.PP +Andy Cress <arcress at users.sourceforge.net> +.br + |