summaryrefslogtreecommitdiff
path: root/NEWS
diff options
context:
space:
mode:
authorJörg Frings-Fürst <debian@jff-webhosting.net>2017-07-15 11:25:39 +0200
committerJörg Frings-Fürst <debian@jff-webhosting.net>2017-07-15 11:25:39 +0200
commit1edb02101a9306fc711cd422ed507d18165b1691 (patch)
treebd2d48a139bfbe869f4f49359b63097931a45e7b /NEWS
parent2ca8a81bd0d99fe4d75c229d0e988d8ef710285f (diff)
move from support/1.0.27 to feature/1.0.27
Diffstat (limited to 'NEWS')
-rw-r--r--NEWS37
1 files changed, 37 insertions, 0 deletions
diff --git a/NEWS b/NEWS
index 31b46ba..bf78d65 100644
--- a/NEWS
+++ b/NEWS
@@ -1,4 +1,41 @@
-*-Mode: outline-*-
+New with 1.0.27 (see Note 1), released 2017-05-22:
+
+* Significant enhancements to canon_dr, epjitsu, epsonds, fujitsu,
+ genesys, hp3500, pixma and xerox-mfp backends.
+* Minor updates, bugfixes or scanners added in several backends.
+* 30+ new scanner models supported.
+* Made libusb-1.0 the default for USB support (see Note 2).
+* Switched code from C90 to C99 (Thanks to Volker Diels-Grabsch).
+* Updated Linux USB3 workaround (see Note 3).
+* Documentation and translation updates.
+* Bugfixes (Avahi, threading, USB, ICC/PNG/JPEG, etc).
+* Reduced compiler warnings, improved code (see Note 4).
+
+Note 1: There is no 1.0.26 release of sane-backends. That number was
+skipped so that our development version numbers would more clearly be
+an extension of the prior release. This should make packaging a little
+easier for our downstream users.
+
+Note 2: On all systems, the --enable-libusb* flags are now ignored.
+Instead, the --with-usb and --without-usb flags now control support.
+When neither is given, USB support will be enabled if possible and
+disabled otherwise. If --with-usb is requested but not possible,
+./configure will fail. There is no support to prefer libusb-0.1 over
+libusb-1.0. When libusb-1.0 is not found, libusb-0.1 will be tried.
+
+Note 3: The Linux USB3 workaround which was added in version 1.0.25 is
+now disabled by default. If you have difficulty using a scanner which
+previously worked, or intermittent scanner availability, try setting
+the new environment variable SANE_USB_WORKAROUND=1 before starting
+your frontend.
+
+Note 4: A special thanks goes to Olaf Meeuwissen for picking up the
+janitorial duties in sane-backends. He has found and fixed a large
+number of long-standing bugs, curated our bug tracker, improved our
+build scripts and docs, and provided user support. Thank you Olaf!
+
+
New with 1.0.25, released 2015-10-03:
* New backends: epsonds (Epson DS, PX and WF series),