diff options
author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2021-02-16 18:24:46 +0100 |
---|---|---|
committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2021-02-16 18:24:46 +0100 |
commit | ecaaf250cb33ff61f37a7b441f2337584a655350 (patch) | |
tree | 4303648095deff998ae20c2393b56db527742ac9 /backend/genesys/genesys.cpp | |
parent | 5793a221e112fa49073de0137d6bfa750a61b0a1 (diff) | |
parent | 351b7328520c16730ceb46e5acae16038c42185e (diff) |
Update upstream source from tag 'upstream/1.0.32'
Update to upstream version '1.0.32'
with Debian dir 2c1111c59d9d68bcbf479a4a4de7697fe2de127f
Diffstat (limited to 'backend/genesys/genesys.cpp')
-rw-r--r-- | backend/genesys/genesys.cpp | 34 |
1 files changed, 17 insertions, 17 deletions
diff --git a/backend/genesys/genesys.cpp b/backend/genesys/genesys.cpp index 9d80cfa..9552fa9 100644 --- a/backend/genesys/genesys.cpp +++ b/backend/genesys/genesys.cpp @@ -28,9 +28,7 @@ General Public License for more details. You should have received a copy of the GNU General Public License - along with this program; if not, write to the Free Software - Foundation, Inc., 59 Temple Place - Suite 330, Boston, - MA 02111-1307, USA. + along with this program. If not, see <https://www.gnu.org/licenses/>. As a special exception, the authors of SANE give permission for additional uses of the libraries contained in this release of SANE. @@ -389,7 +387,7 @@ void sanei_genesys_create_default_gamma_table(Genesys_Device* dev, TODO: Should also consider maximum transfer rate: ~6.5MB/s. Note: The enhance option of the scanners does _not_ help. It only halves - the amount of pixels transfered. + the amount of pixels transferred. */ SANE_Int sanei_genesys_exposure_time2(Genesys_Device * dev, const MotorProfile& profile, float ydpi, int endpixel, int exposure_by_led) @@ -3204,7 +3202,7 @@ compute_shifted_coefficients (Genesys_Device * dev, unsigned int coeff, unsigned int target_dark, unsigned int target_bright, - unsigned int patch_size) /* contigous extent */ + unsigned int patch_size) /* contiguous extent */ { unsigned int x, avgpixels, basepixels, i, j, val1, val2; unsigned int br_tmp [3], dk_tmp [3]; @@ -3573,7 +3571,7 @@ static void genesys_send_shading_coefficient(Genesys_Device* dev, const Genesys_ coeff, 0x0001, /* target_dark */ 0xf900, /* target_bright */ - 256); /* patch_size: contigous extent */ + 256); /* patch_size: contiguous extent */ break; default: throw SaneException(SANE_STATUS_UNSUPPORTED, "sensor %d not supported", @@ -3598,7 +3596,7 @@ genesys_restore_calibration(Genesys_Device * dev, Genesys_Sensor& sensor) { DBG_HELPER(dbg); - // if no cache or no function to evaluate cache entry ther can be no match/ + // if no cache or no function to evaluate cache entry there can be no match/ if (dev->calibration_cache.empty()) { return false; } @@ -4061,7 +4059,7 @@ static void genesys_start_scan(Genesys_Device* dev, bool lamp_off) unsigned int steps, expected; - /* since not all scanners are set ot wait for head to park + /* since not all scanners are set to wait for head to park * we check we are not still parking before starting a new scan */ if (dev->parking) { sanei_genesys_wait_for_home(dev); @@ -4166,7 +4164,7 @@ static void genesys_start_scan(Genesys_Device* dev, bool lamp_off) return; } - /*do we really need this? the valid data check should be sufficent -- pierre*/ + /*do we really need this? the valid data check should be sufficient -- pierre*/ /* waits for head to reach scanning position */ expected = dev->reg.get8(0x3d) * 65536 + dev->reg.get8(0x3e) * 256 @@ -4214,7 +4212,7 @@ static void genesys_read_ordered_data(Genesys_Device* dev, SANE_Byte* destinatio /* is there data left to scan */ if (dev->total_bytes_read >= dev->total_bytes_to_read) { - /* issue park command immediatly in case scanner can handle it + /* issue park command immediately in case scanner can handle it * so we save time */ if (!dev->model->is_sheetfed && !has_flag(dev->model->flags, ModelFlag::MUST_WAIT) && !dev->parking) @@ -4374,7 +4372,7 @@ static Genesys_Settings calculate_scan_settings(Genesys_Scanner* s) settings.true_gray = 0; } - // brigthness and contrast only for for 8 bit scans + // brightness and contrast only for for 8 bit scans if (s->bit_depth == 8) { settings.contrast = (s->contrast * 127) / 100; settings.brightness = (s->brightness * 127) / 100; @@ -4479,7 +4477,7 @@ static SANE_Range create_range(float size) /** @brief generate calibration cache file nam * Generates the calibration cache file name to use. - * Tries to store the chache in $HOME/.sane or + * Tries to store the cache in $HOME/.sane or * then fallbacks to $TMPDIR or TMP. The filename * uses the model name if only one scanner is plugged * else is uses the device name when several identical @@ -4864,7 +4862,7 @@ static void init_options(Genesys_Scanner* s) s->opt[OPT_CALIBRATION_FILE].cap = SANE_CAP_SOFT_DETECT | SANE_CAP_SOFT_SELECT | SANE_CAP_ADVANCED; s->opt[OPT_CALIBRATION_FILE].constraint_type = SANE_CONSTRAINT_NONE; s->calibration_file.clear(); - /* disable option if ran as root */ + /* disable option if run as root */ #ifdef HAVE_GETUID if(geteuid()==0) { @@ -5186,7 +5184,8 @@ static SANE_Status attach_one_device(SANE_String_Const devname) noexcept // this function is passed to C API, it must not throw static SANE_Status -config_attach_genesys(SANEI_Config __sane_unused__ *config, const char *devname) noexcept +config_attach_genesys(SANEI_Config __sane_unused__ *config, const char *devname, + void __sane_unused__ *data) noexcept { /* the devname has been processed and is ready to be used * directly. Since the backend is an USB only one, we can @@ -5214,7 +5213,8 @@ static void probe_genesys_devices() config.values = nullptr; config.count = 0; - auto status = sanei_configure_attach(GENESYS_CONFIG_FILE, &config, config_attach_genesys); + auto status = sanei_configure_attach(GENESYS_CONFIG_FILE, &config, + config_attach_genesys, NULL); if (status == SANE_STATUS_ACCESS_DENIED) { dbg.vlog(DBG_error0, "Critical error: Couldn't access configuration file '%s'", GENESYS_CONFIG_FILE); @@ -5346,7 +5346,7 @@ void sane_init_impl(SANE_Int * version_code, SANE_Auth_Callback authorize) #endif ); - // cold-plug case :detection of allready connected scanners + // cold-plug case :detection of already connected scanners s_attach_device_by_name_evaluate_bcd_device = false; probe_genesys_devices(); } @@ -6333,7 +6333,7 @@ SANE_Status sane_read_impl(SANE_Handle handle, SANE_Byte * buf, SANE_Int max_len { DBG(DBG_proc, "%s: nothing more to scan: EOF\n", __func__); - /* issue park command immediatly in case scanner can handle it + /* issue park command immediately in case scanner can handle it * so we save time */ if (!dev->model->is_sheetfed && !has_flag(dev->model->flags, ModelFlag::MUST_WAIT) && !dev->parking) |