diff options
author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-10-06 14:00:40 +0200 |
---|---|---|
committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-10-06 14:00:40 +0200 |
commit | 6e9c41a892ed0e0da326e0278b3221ce3f5713b8 (patch) | |
tree | 2e301d871bbeeb44aa57ff9cc070fcf3be484487 /backend/plustek.conf.in |
Initial import of sane-backends version 1.0.24-1.2
Diffstat (limited to 'backend/plustek.conf.in')
-rw-r--r-- | backend/plustek.conf.in | 184 |
1 files changed, 184 insertions, 0 deletions
diff --git a/backend/plustek.conf.in b/backend/plustek.conf.in new file mode 100644 index 0000000..e16823e --- /dev/null +++ b/backend/plustek.conf.in @@ -0,0 +1,184 @@ +# Plustek-SANE Backend configuration file +# For use with LM9831/2/3 based USB scanners +# + +# each device needs at least two lines: +# - [usb] vendor-ID and product-ID +# - device devicename +# i.e. for Plustek (0x07B3) UT12/16/24 (0x0017) +# [usb] 0x07B3 0x0017 +# device /dev/usbscanner +# or +# device libusb:bbb:ddd +# where bbb is the busnumber and ddd the device number +# make sure that your user has access to /proc/bus/usb/bbb/ddd +# +# additionally you can specify some options +# warmup, lOffOnEnd, lampOff +# +# For autodetection use +# [usb] +# device /dev/usbscanner +# +# or simply +# [usb] +# +# or if you want a specific device but you have no idea about the +# device node or you use libusb, simply set vendor- and product-ID +# [usb] 0x07B3 0x0017 +# device auto +# +# NOTE: autodetection is safe, as it uses the info it got +# from the USB subsystem. If you're not using the +# autodetection, you MUST have attached that device +# at your USB-port, that you have specified... +# + +[usb] + +# +# options for the previous USB entry +# +# switch lamp off after xxx secs, 0 disables the feature +# (can also be set via frontend) +option lampOff 300 + +# warmup period in seconds, 0 means no warmup, -1 means auto-warmup +# (can also be set via frontend) +option warmup -1 + +# 0 means leave lamp-status untouched, not 0 means switch off +# on sane_close +# (can also be set via frontend) +option lOffOnEnd 1 + +# +# options to tweak the image start-position +# (WARNING: there's no internal range check!!!) +# +# for the normal scan area +# +option posOffX 0 +option posOffY 0 + +# for transparencies +option tpaOffX 0 +option tpaOffY 0 + +# for negatives +option negOffX 0 +option negOffY 0 + +# +# for setting the calibration strip position +# (WARNING: there's no internal range check!!!) +# -1 means use built in +# (can also be set via frontend) +option posShadingY -1 +option tpaShadingY -1 +option negShadingY -1 + +# +# to invert the negatives, 0 disables the feature +# +option invertNegatives 0 + +# +# to disable the internal sensor speedup function, +# 1 disables the feature +# +option disableSpeedup 0 + +# +# to save/restore coarse calibration data +# (can also be set via frontend) +option cacheCalData 0 + +# +# use alternate calibration routines +# +option altCalibration 0 + +# +# for skipping whole calibration step +# +option skipCalibration 0 + +# +# for skipping entire fine calibration step +# coarse calibration is done +# +option skipFine 0 + +# +# discard the result of the fine white calibration +# +option skipFineWhite 0 + +# +# some scanners have a dark calibration strip, in +# general this one should be used for calibration. +# As this could cause some trouble, this option +# overrides that and the dark calibration will be +# done by switching the lamp off +# +option skipDarkStrip 0 + +# for replacing the gain values found during coarse +# calibration +# (can also be set via frontend) +option red_gain -1 +option green_gain -1 +option blue_gain -1 + +# for replacing the offset values found during coarse +# calibration +# (can also be set via frontend) +option red_offset -1 +option green_offset -1 +option blue_offset -1 + +# +# for replacing the default lampoff settings, this +# works only for CIS devices like CanoScan LiDE20 +# (can also be set via frontend) +option red_lampoff -1 +option green_lampoff -1 +option blue_lampoff -1 + +# +# for adjusting the default gamma values +# (can also be set via frontend) +option redGamma 1.0 +option greenGamma 1.0 +option blueGamma 1.0 +option grayGamma 1.0 + +# +# to enable TPA (EPSON or UMAX, if autodetection fails) +# 0 means default behaviour as specified in the internal tables +# 1 means enable (needed for UMAX 3450) +option enableTPA 0 + +# +# model override functionality, currently only available for +# Mustek devices, using NSCs' vendor ID: 0x0400 and +# also their product ID: 0x1000 (LM9831) 0x1001 (LM9832) +# +# mov/PID | 0x1000 | 0x1001 +# --------------------------------------- +# 0 (default)| BearPaw1200 | BearPaw 2400 +# 1 | ignored | BearPaw 1200 +# +option mov 0 + +# +# and of course the device-name +# +# device /dev/usbscanner +device auto + +# +# to define a new device, start with a new section: +# [usb] +# |