diff options
author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-10-06 14:00:40 +0200 |
---|---|---|
committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-10-06 14:00:40 +0200 |
commit | 6e9c41a892ed0e0da326e0278b3221ce3f5713b8 (patch) | |
tree | 2e301d871bbeeb44aa57ff9cc070fcf3be484487 /doc/niash |
Initial import of sane-backends version 1.0.24-1.2
Diffstat (limited to 'doc/niash')
-rw-r--r-- | doc/niash/niash.TODO | 64 |
1 files changed, 64 insertions, 0 deletions
diff --git a/doc/niash/niash.TODO b/doc/niash/niash.TODO new file mode 100644 index 0000000..ded62ca --- /dev/null +++ b/doc/niash/niash.TODO @@ -0,0 +1,64 @@ +To do: +====== +- implement coarse calibration to determine settings for analog-front-end + All CCDs encountered so far seem to need about the same settings however. + +- Store analog calibration data somewhere. + Use currently used values as default. + +- Suggestions by Marcin Cieslak: + - clean up structures + - clean up namespace + - clean up source formatting ('indent --gnu' ?) + + +- implement real calibration, using 12 bit data at 600 dpi + instead of 8 bit data.at 150 dpi. + -> is now at 600 dpi, not yet at 12 bit + +- design a mechanism to set the scan and calibration areas + a) part of HWProps structure, or + b) set by user at first scan + +- further investigate scanner registers + a) study backtracking register more + b) identify bits in bit-oriented registers. + +- add more error checking ('sanity checking') on parameters + +- figure out what the USB interrupts mean that sometimes occur. + + + +Done +==== + +- Get rid of mytypes.h / fix types + Now an int is implicitly assumed to be 32 bit. + +- make backend comply with tstbackend +-> all externs and publics removed when compiling towards sane + +- implement sane_cancel properly +-> done by ullsig + +- implement timing mechanism for scanner lamp + so scanning can only start if the lamp was already on for 30 seconds +Possible implementation: +On startup: if lamp is off, turn it on and start timer +On scan: if lamp is off, turn it on and start timer. Wait for timer expiry. +On exit: if scanner chip is niash00012 then turn off lamp, + otherwise let the scanner turn it off automatically +-> Implemented by Ullrich Sigwanz + +- try out parallel port scanning on HP3400/4300 +-> parallel port support will be dropped, no people to test/develop it + +- investigate vertical resolution setting of hp3400/4300. +-> experiment with the motor table, formula is already known to generate it +-> 600 dpi is possible by doubling most values in the table +-> 150 dpi can be done by using register 0x06 to skip every other line + +- Add separate gamma tables for R, G, B. This should be easy (look at how + other backends do it) but is not really required yet. +-> not required |