diff options
author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-10-06 14:00:40 +0200 |
---|---|---|
committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-10-06 14:00:40 +0200 |
commit | 6e9c41a892ed0e0da326e0278b3221ce3f5713b8 (patch) | |
tree | 2e301d871bbeeb44aa57ff9cc070fcf3be484487 /doc/plustek/Plustek-USB-TODO.txt |
Initial import of sane-backends version 1.0.24-1.2
Diffstat (limited to 'doc/plustek/Plustek-USB-TODO.txt')
-rw-r--r-- | doc/plustek/Plustek-USB-TODO.txt | 53 |
1 files changed, 53 insertions, 0 deletions
diff --git a/doc/plustek/Plustek-USB-TODO.txt b/doc/plustek/Plustek-USB-TODO.txt new file mode 100644 index 0000000..0ea7e8b --- /dev/null +++ b/doc/plustek/Plustek-USB-TODO.txt @@ -0,0 +1,53 @@ +Plustek-USB-TODO.txt (2007-12-13) Gerhard Jaeger <gerhard@gjaeger.de> +===================================================================== + +TODO (in general): +- more documentation/comments for the different functions +- replace mclk_fast stuff and use instead values from 75DPI grayscale + + +KNOWN BUGS/Limitations: + +Model Description Workaround +------------------------------------------------------------------------------ + +HP 2100c Straight Line Bug none +Bearpaw1200 works only once restart backend each time +All with TPA Negative Scanning quality bad none +CIS devices Skip calibration does not work none + +********************************* DONE *************************************** + +all add plustek.conf presettings to done + interface for frontends + +all Auto-warmup done +all Sensor movement speedup ffw/rev done + +Canon fine calibration does not work fixed +Canon 650 color modes >=600 dpi too dark fixed +Canon 660 add support done +Canon 1220 image quality not very good fixed +Canon 1240 gray mode too bright fixed + +HP 2100c hits against scan-bed fixed +Genius Devices not recognized fixed +EPSON Photo Permanently warmup on TPA scanning fixed +EPSON Photo Transparency mode does not work fixed + correctly +all binary mode does not work correctly done +Canon 16bit gray mode does not work done +EPSON 1250/60 Motor control settings are wrong fixed +CanoScan 1240 added +EPSON + HP vertical line bug fixed +HP blooming on 42bit >=400dpi fixed +UMAX5400 bad picture quality fixed +UMAX3400 Straight Line Bug fixed +all problems on ARM and XScale fixed + +Make the color modes > 8bit work correctly done +make mono/gray modes work on Canon scanners done +copy picture line by line to backend done +cancel function does not work correctly in large resolutions fixed +Move documents to its correct SANE place done + |