summaryrefslogtreecommitdiff
path: root/doc/plustek/Plustek-USB-TODO.txt
diff options
context:
space:
mode:
authorJörg Frings-Fürst <debian@jff-webhosting.net>2014-10-06 14:00:40 +0200
committerJörg Frings-Fürst <debian@jff-webhosting.net>2014-10-06 14:00:40 +0200
commit6e9c41a892ed0e0da326e0278b3221ce3f5713b8 (patch)
tree2e301d871bbeeb44aa57ff9cc070fcf3be484487 /doc/plustek/Plustek-USB-TODO.txt
Initial import of sane-backends version 1.0.24-1.2
Diffstat (limited to 'doc/plustek/Plustek-USB-TODO.txt')
-rw-r--r--doc/plustek/Plustek-USB-TODO.txt53
1 files changed, 53 insertions, 0 deletions
diff --git a/doc/plustek/Plustek-USB-TODO.txt b/doc/plustek/Plustek-USB-TODO.txt
new file mode 100644
index 0000000..0ea7e8b
--- /dev/null
+++ b/doc/plustek/Plustek-USB-TODO.txt
@@ -0,0 +1,53 @@
+Plustek-USB-TODO.txt (2007-12-13) Gerhard Jaeger <gerhard@gjaeger.de>
+=====================================================================
+
+TODO (in general):
+- more documentation/comments for the different functions
+- replace mclk_fast stuff and use instead values from 75DPI grayscale
+
+
+KNOWN BUGS/Limitations:
+
+Model Description Workaround
+------------------------------------------------------------------------------
+
+HP 2100c Straight Line Bug none
+Bearpaw1200 works only once restart backend each time
+All with TPA Negative Scanning quality bad none
+CIS devices Skip calibration does not work none
+
+********************************* DONE ***************************************
+
+all add plustek.conf presettings to done
+ interface for frontends
+
+all Auto-warmup done
+all Sensor movement speedup ffw/rev done
+
+Canon fine calibration does not work fixed
+Canon 650 color modes >=600 dpi too dark fixed
+Canon 660 add support done
+Canon 1220 image quality not very good fixed
+Canon 1240 gray mode too bright fixed
+
+HP 2100c hits against scan-bed fixed
+Genius Devices not recognized fixed
+EPSON Photo Permanently warmup on TPA scanning fixed
+EPSON Photo Transparency mode does not work fixed
+ correctly
+all binary mode does not work correctly done
+Canon 16bit gray mode does not work done
+EPSON 1250/60 Motor control settings are wrong fixed
+CanoScan 1240 added
+EPSON + HP vertical line bug fixed
+HP blooming on 42bit >=400dpi fixed
+UMAX5400 bad picture quality fixed
+UMAX3400 Straight Line Bug fixed
+all problems on ARM and XScale fixed
+
+Make the color modes > 8bit work correctly done
+make mono/gray modes work on Canon scanners done
+copy picture line by line to backend done
+cancel function does not work correctly in large resolutions fixed
+Move documents to its correct SANE place done
+