summaryrefslogtreecommitdiff
path: root/doc/sane-abaton.man
diff options
context:
space:
mode:
authorJörg Frings-Fürst <debian@jff-webhosting.net>2021-02-16 18:24:19 +0100
committerJörg Frings-Fürst <debian@jff-webhosting.net>2021-02-16 18:24:19 +0100
commit351b7328520c16730ceb46e5acae16038c42185e (patch)
treefae21fd5c94f3c3ed0202a95c9ada705482e647b /doc/sane-abaton.man
parentad38bc6ecb80ddeb562841b33258dd53659b1da6 (diff)
New upstream version 1.0.32upstream/1.0.32
Diffstat (limited to 'doc/sane-abaton.man')
-rw-r--r--doc/sane-abaton.man40
1 files changed, 28 insertions, 12 deletions
diff --git a/doc/sane-abaton.man b/doc/sane-abaton.man
index f1f33cb..13c3c6b 100644
--- a/doc/sane-abaton.man
+++ b/doc/sane-abaton.man
@@ -16,7 +16,8 @@ works with this backend, or if you own an Abaton scanner that does not
work with this backend, please contact
.IR sane\-devel@alioth-lists.debian.net
with the model number, so that arrangements can be made to include
-support for it. Have a look at http://www.sane\-project.org/mailing\-lists.html
+support for it. Have a look at
+.I http://www.sane\-project.org/mailing\-lists.html
concerning subscription to sane\-devel.
.PP
Abaton is out of business, and these scanners are not supported by
@@ -48,13 +49,17 @@ name takes a format such as
.I /dev/sga
or
.IR /dev/sg0 ,
-for example. See sane\-scsi(5) for details.
+for example. See
+.BR sane\-scsi (5)
+for details.
+
.SH CONFIGURATION
The contents of the
.I abaton.conf
file is a list of device names that correspond to Abaton scanners.
Empty lines and lines starting with a hash mark (#) are ignored. See
-sane\-scsi(5) on details of what constitutes a valid device name.
+.BR sane\-scsi (5)
+on details of what constitutes a valid device name.
.SH FILES
.TP
@@ -77,13 +82,18 @@ contain the configuration file. Under UNIX, the directories are
separated by a colon (`:'), under OS/2, they are separated by a
semi-colon (`;'). If this variable is not set, the configuration file
is searched in two default directories: first, the current working
-directory (".") and then in @CONFIGDIR@. If the value of the
-environment variable ends with the directory separator character, then
-the default directories are searched after the explicitly specified
-directories. For example, setting
+directory (".") and then in
+.IR @CONFIGDIR@ .
+If the value of the environment variable ends with the directory separator
+character, then the default directories are searched after the explicitly
+specified directories. For example, setting
.B SANE_CONFIG_DIR
-to "/tmp/config:" would result in directories "tmp/config", ".", and
-"@CONFIGDIR@" being searched (in this order).
+to "/tmp/config:" would result in directories
+.IR tmp/config ,
+.IR . ,
+and
+.I @CONFIGDIR@
+being searched (in this order).
.TP
.B SANE_DEBUG_ABATON
If the library was compiled with debug support enabled, this
@@ -119,8 +129,14 @@ confidence that it will work, as well as to fully exploit the
information returned by the INQUIRY command.
.SH "SEE ALSO"
-sane(7), sane\-scsi(5), scanimage(1)
+.BR sane (7),
+.BR sane\-scsi (5),
+.BR scanimage (1)
.SH AUTHOR
-The sane\-abaton backend was partially written by David Huggins-Daines,
-based on the sane\-apple backend by Milon Firikis.
+The
+.B sane\-abaton
+backend was partially written by David Huggins-Daines,
+based on the
+.BR sane\-apple (5)
+backend by Milon Firikis.