summaryrefslogtreecommitdiff
path: root/doc/sane-epson.man
diff options
context:
space:
mode:
authorJörg Frings-Fürst <debian@jff-webhosting.net>2021-02-16 18:24:46 +0100
committerJörg Frings-Fürst <debian@jff-webhosting.net>2021-02-16 18:24:46 +0100
commitecaaf250cb33ff61f37a7b441f2337584a655350 (patch)
tree4303648095deff998ae20c2393b56db527742ac9 /doc/sane-epson.man
parent5793a221e112fa49073de0137d6bfa750a61b0a1 (diff)
parent351b7328520c16730ceb46e5acae16038c42185e (diff)
Update upstream source from tag 'upstream/1.0.32'
Update to upstream version '1.0.32' with Debian dir 2c1111c59d9d68bcbf479a4a4de7697fe2de127f
Diffstat (limited to 'doc/sane-epson.man')
-rw-r--r--doc/sane-epson.man105
1 files changed, 63 insertions, 42 deletions
diff --git a/doc/sane-epson.man b/doc/sane-epson.man
index f09f075..75ffad3 100644
--- a/doc/sane-epson.man
+++ b/doc/sane-epson.man
@@ -5,7 +5,7 @@ sane\-epson \- SANE backend for EPSON scanners
.SH DESCRIPTION
The
.B sane\-epson
-library implements a SANE (Scanner Access Now Easy) backend that
+library implements a SANE Scanner Access Now Easy) backend that
provides access to Epson flatbed scanners. Some functions of this
backend should be considered
.B beta-quality
@@ -49,22 +49,30 @@ and many more. The official list is on the Sane web site.
.RE
For other scanners the software may or may not work. Please send mail to
-the backend author (khk@khk.net) to report success with scanners not on
-the list or problems with scanners that are listed.
+the backend author
+.RI ( khk@khk.net )
+to report success with scanners not on the list or problems with scanners
+that are listed.
.SH OPTIONS
The options the backend supports can either be selected through command line
-options to programs like scanimage or through GUI elements in programs like
-xscanimage or xsane.
-
-Valid command line options and their syntax can be listed by using
+options to programs like
+.BR scanimage (1)
+or through GUI elements in programs like
+.BR xscanimage (1)
+or
+.BR xsane (1).
+
+Valid command line options and their syntax can be listed by using:
+.PP
.RS
scanimage \-\-help \-d epson
.RE
+.PP
Not all devices support all options.
.TP
.I Scan Mode
The
-.I \-\-mode
+.B \-\-mode
switch selects the basic mode of operation of the scanner. Valid choices
are Binary, Gray and Color. The Binary mode is black and white only,
Gray will produce 256 levels of gray or more depending on the scanner
@@ -73,7 +81,7 @@ Some scanners will internally use 36 bit color, their external interface
however may only support 24 bits.
The
-.I \-\-depth
+.B \-\-depth
option selects the bit depth the scanner is using. This option is only
available for scanners that support more than one bit depth. Older
scanners will always transfer the image in 8bit mode. Newer scanners
@@ -82,7 +90,7 @@ color scan this means an effective color depth of 36 or 42 bits over
all three channels. The valid choices depend on the scanner model.
The
-.I \-\-halftoning
+.B \-\-halftoning
switch selects the mode that is used in Binary mode. Valid options
are "None", "Halftone A (Hard Tone)", "Halftone B (Soft Tone)", "Halftone C
(Net Screen)", "Dither A (4x4 Bayer)", "Dither B (4x4 Spiral)", "Dither C
@@ -90,129 +98,136 @@ are "None", "Halftone A (Hard Tone)", "Halftone B (Soft Tone)", "Halftone C
"Download pattern A", and "Download pattern B".
The
-.I \-\-dropout
+.B \-\-dropout
switch selects the so called dropout color. Valid options are None,
Red, Green and Blue. The default is None. The dropout color is used for
monochrome scanning and selects the color that is not scanned. This can
be used to e.g. scan an original with a colored background.
The
-.I \-\-brightness
+.B \-\-brightness
switch controls the brightness of the scan. Valid options are integer
values from \-3 to 3. The default is 0. The larger the brightness value,
the brighter the image gets. If a user defined table for the gamma
correction is selected, the brightness parameter is not available.
The
-.I \-\-sharpness
+.B \-\-sharpness
switch sets the sharpness of the image data. Valid options are integer
values from \-2 to 2, with \-2 meaning "Defocus", \-1 "Defocus slightly",
0 "Normal", 1 "Sharpen slightly" and 2 "Sharpen".
The
-.I \-\-gamma\-correction
+.B \-\-gamma\-correction
switch controls the scanner's internal gamma correction. Valid options are
"Default", "User defined", "High density printing" "Low density printing"
and "High contrast printing".
The
-.I \-\-color\-correction
+.B \-\-color\-correction
switch controls the scanner's internal color correction function. Valid
options are "No Correction", "Impact\-dot printers", "Thermal printers",
"Ink\-jet printers" and "CRT monitors". The default is "CRT monitors".
The
-.I \-\-resolution
+.B \-\-resolution
switch selects the resolution for a scan. Some EPSON scanners will scan in
any resolution between the lowest and highest possible value. The list
reported by the scanner can be displayed using the "\-\-help \-d epson"
-parameters to scanimage.
+parameters to
+.BR scanimage (1).
The
-.I \-\-mirror
+.B \-\-mirror
option controls the way the image is scanned. By reading the image data
from right to left the image is mirrored. Valid options are "yes" and
"no". The default is "no".
The
-.I \-\-speed
+.B \-\-speed
option can improve the scan speed in monochrome mode. Valid options are
"yes" or "no", the "yes" option will speed up the scan if this option
is supported.
The
-.I \-\-auto\-area\-segmentation
+.B \-\-auto\-area\-segmentation
switch activates the automatic area segmentation for monochrome scans. The
scanner will try to determine which areas are text and which contain
images. The image areas will be halftoned, and the text will be
improved. Valid options are "yes" and "no". The default is "yes".
The
-.I \-\-gamma\-table
+.B \-\-gamma\-table
parameter can be used to download a user defined gamma table. The option
takes 256 values from the range 0-255. In color mode this option equally
affects the red, green, and blue channel.
The
-.I \-\-red\-gamma\-table
+.B \-\-red\-gamma\-table
parameter can be used to download a user defined gamma table for the
red channel. The valid options are the same as for \-\-gamma\-table.
The
-.I \-\-green\-gamma\-table
+.B \-\-green\-gamma\-table
parameter can be used to download a user defined gamma table for the
green channel. The valid options are the same as for \-\-gamma\-table.
The
-.I \-\-blue\-gamma\-table
+.B \-\-blue\-gamma\-table
parameter can be used to download a user defined gamma table for the
blue channel. The valid options are the same as for \-\-gamma\-table.
The color correction coefficients
-.I \-\-cct\-1 \-\-cct\-2 \-\-cct\-3 ... \-\-cct\-9
+.B \-\-cct\-1 \-\-cct\-2 \-\-cct\-3 ... \-\-cct\-9
will install color correction coefficients for the user defined color
correction. Values are specified as integers in the range \-127..127.
The
-.I \-\-preview
+.B \-\-preview
option requests a preview scan. The frontend software automatically selects a low
resolution. Valid options are "yes" and "no". The default is "no".
The
-.I \-\-preview\-speed
+.B \-\-preview\-speed
options will increase the scan speed if this is supported by the
scanner. Valid options are "yes" and "no", the default is "no".
The geometry options
-.I \-l \-t \-x \-y
-control the scan area: \-l sets the top left x coordinate, \-t the top
-left y coordinate, \-x selects the width and \-y the height of the scan
-area. All parameters are specified in millimeters.
+.B \-l \-t \-x \-y
+control the scan area:
+.B \-l
+sets the top left x coordinate,
+.B \-t
+the top left y coordinate,
+.B \-x
+selects the width and
+.B \-y
+the height of the scan area. All parameters are specified in millimeters.
The
-.I \-\-quick\-format
+.B \-\-quick\-format
option lets the user select a scan area with predefined sizes. Valid
parameters are "CD", "A5 portrait", "A5 landscape", "Letter", "A4" and
"max". The default is "max", which selects the largest possible area.
The
-.I \-\-source
+.B \-\-source
option selects the scan source. Valid options depend on the installed
options. The default is "Flatbed".
The
-.I \-\-auto\-eject
+.B \-\-auto\-eject
option will eject a page after scanning from the document feeder.
The
-.I \-\-film\-type
+.B \-\-film\-type
option will select the film type for scans with the transparency
unit. This option is only activated if the TPU is selected as scan
source. Valid options are "Negative Film" and "Positive Film".
The
-.I \-\-focus\-position
+.B \-\-focus\-position
option selects the focus position for all scans. Valid options are "Focus
2.5mm above glass" and "Focus on glass". The focus on the 2.5mm point
above the glass is necessary for scans with the transparency unit, so
@@ -222,13 +237,15 @@ will ignore this option.
.SH CONFIGURATION FILE
-The configuration file @CONFIGDIR@/epson.conf specifies the device(s) that the
-backend will use. Possible connection types are:
+The configuration file
+.I @CONFIGDIR@/epson.conf
+specifies the device(s) that the backend will use. Possible connection types are:
.TP
.I SCSI
This is the default, and if nothing else is specified the backend software will
open a given path as SCSI device. More information about valid syntax for SCSI
-devices can be found in sane\-scsi(5).
+devices can be found in
+.BR sane\-scsi (5).
.br
Usually SCSI scanners are configured with a line "scsi EPSON" in this file. In
some cases it may be necessary to only use the string "scsi" (e.g. for the GT-6500).
@@ -279,7 +296,10 @@ only if you know what you are doing!
.SH "SEE ALSO"
-sane\-scsi(5), scanimage(1), xscanimage(1), xsane(1)
+.BR sane\-scsi (5),
+.BR scanimage (1),
+.BR xscanimage (1),
+.BR xsane (1)
.SH BUGS
@@ -302,5 +322,6 @@ Perfection 1260 are not supported by this backend.
.SH AUTHOR
-The package is actively maintained by Karl Heinz Kremer (khk@khk.net). The
-software is based on work by Christian Bucher and Kazuhiro Sasayama
+The package is actively maintained by Karl Heinz Kremer
+.RI ( khk@khk.net ).
+The software is based on work by Christian Bucher and Kazuhiro Sasayama.