diff options
author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2019-07-31 17:00:20 +0200 |
---|---|---|
committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2019-07-31 17:00:20 +0200 |
commit | 3759ce55ba79b8d3b9d8ed247a252273ee7dade3 (patch) | |
tree | d69692a274dd1c7d0672e6bb7155a0fc106f9d49 /doc/sane-p5.man | |
parent | c8bd2513ecba169cff44c09c8058c36987357b18 (diff) | |
parent | 1687222e1b9e74c89cafbb5910e72d8ec7bfd40f (diff) |
Update upstream source from tag 'upstream/1.0.28'
Update to upstream version '1.0.28'
with Debian dir ec5bb298266630fc3801ff6dc0c258f6df7ba979
Diffstat (limited to 'doc/sane-p5.man')
-rw-r--r-- | doc/sane-p5.man | 73 |
1 files changed, 37 insertions, 36 deletions
diff --git a/doc/sane-p5.man b/doc/sane-p5.man index 860a019..1c21f12 100644 --- a/doc/sane-p5.man +++ b/doc/sane-p5.man @@ -7,28 +7,28 @@ The .B sane\-p5 library implements a SANE (Scanner Access Now Easy) backend that provides access to the Primax PagePartner parallel port sheet fed scanner. -.PP +.PP This backend handles 100, 150, 200, 300 and 600 dpi scan resolutions, in color and gray modes. The 600 dpi is actually 300x600 with lines enlarged to match the vertical resolution. -.PP +.PP .B EPP/ECP MODES ONLY -The current version of the backend uses only EPP or ECP mode to communicate -with the scanner. It is -recommended that you set your parallel port to EPP in BIOS with the current +The current version of the backend uses only EPP or ECP mode to communicate +with the scanner. It is +recommended that you set your parallel port to EPP in BIOS with the current version of this backend. ECPEPP will only work if you use a 2.4 or 2.6 kernel with ppdev character device support. -.PP +.PP .SH "DEVICE NAMES" This backend expects device names of the form: -.PP +.PP .RS .I port value .RE -.PP +.PP Where -\fBvalue\fR is : +\fBvalue\fR is : .RS .TP @@ -40,43 +40,43 @@ them for scanner uses linux ppdev device, depending on the number of available parallel port, you have to use /dev/parport1, /dev/parport2, ... -.PP +.PP .RE You can rename any device using the -.PP +.PP .RS .br .I option name my_name .RE -.PP -option. This option apply to the last port option. +.PP +option. This option apply to the last port option. .SH "CONFIGURATION" Please make sure to edit dll.conf .B before you use the backend, since this backend isn't enabled by default. -.PP +.PP -.PP +.PP .SH "FILES" -.TP +.TP .I @CONFIGDIR@/p5.conf The backend configuration file (see also description of .B SANE_CONFIG_DIR below). -.TP +.TP .I @LIBDIR@/libsane\-p5.a The static library implementing this backend. -.TP +.TP .I @LIBDIR@/libsane\-p5.so The shared library implementing this backend (present on systems that support dynamic loading). .SH "ENVIRONMENT" -.TP +.TP .B SANE_CONFIG_DIR This environment variable specifies the list of directories that may contain the configuration file. Under UNIX, the directories are @@ -90,14 +90,14 @@ directories. For example, setting .B SANE_CONFIG_DIR to "/tmp/config:" would result in directories "tmp/config", ".", and "@CONFIGDIR@" being searched (in this order). -.TP +.TP .B SANE_DEBUG_P5 If the library was compiled with debug support enabled, this environment variable controls the debug level for this backend. E.g., a value of 255 requests all debug output to be printed. Smaller levels reduce verbosity. -.PP +.PP .RS .ft CR .nf @@ -108,23 +108,23 @@ level debug output 2 warnings & minor errors 4 information messages 8 start/stop of functions - 16 tracing messages + 16 tracing messages 32 I/O functions 64 I/O functions with traces 128 scanned/calibration data .fi .ft R .RE -.PP -.TP +.PP +.TP -.PP +.PP .RS .ft CR .nf -.PP - -.PP +.PP + +.PP .SH "SEE ALSO" sane(7), sane\-net(5), saned(8) @@ -136,25 +136,26 @@ Support for the Prima PagePartner has been made possible thank to an hardware do by S\['e]bastien Lange. .SH "BUG REPORTS" -If something doesn't work mail sane-devel@lists.alioth.debian.org or use the bug -tracker at https://alioth.debian.org/tracker/?atid=410366&group_id=30186 . -Please give as much information as you can. +If something doesn't work mail sane-devel@alioth-lists.debian.net or submit an +issue via https://gitlab.com/sane-project/backends/issues/new with a label of +backend/p5. +Please give as much information as you can. -.TP +.TP .I SANE version run "scanimage \-V" to determine this -.TP +.TP .I the backend version and your scanner hardware run "SANE_DEBUG_P5=255 scanimage \-L 2>log" as root. If you don't get any output from the p5 backend, make sure a line "p5" is included into your @CONFIGDIR@/dll.conf. If your scanner isn't detected, make sure you've defined the right port address, or the -correct device +correct device in your p5.conf. -.TP +.TP .I the name of your scanner/vendor also a worthy information. Please also include the optical resolution and lamp type of your scanner, both can be found in the manual of your scanner. -.TP +.TP .I any further comments if you have comments about the documentation (what could be done better), or you think I should know something, please include it. |