diff options
author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-10-06 14:00:40 +0200 |
---|---|---|
committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-10-06 14:00:40 +0200 |
commit | 6e9c41a892ed0e0da326e0278b3221ce3f5713b8 (patch) | |
tree | 2e301d871bbeeb44aa57ff9cc070fcf3be484487 /doc/sane-plustek.man |
Initial import of sane-backends version 1.0.24-1.2
Diffstat (limited to 'doc/sane-plustek.man')
-rw-r--r-- | doc/sane-plustek.man | 521 |
1 files changed, 521 insertions, 0 deletions
diff --git a/doc/sane-plustek.man b/doc/sane-plustek.man new file mode 100644 index 0000000..a6bb993 --- /dev/null +++ b/doc/sane-plustek.man @@ -0,0 +1,521 @@ +.TH sane\-plustek 5 "13 Feb 2013" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy" +.IX sane\-plustek +.SH NAME +sane\-plustek \- SANE backend for LM983[1/2/3] based +USB flatbed scanners +.SH DESCRIPTION +The +.B sane\-plustek +library implements a SANE (Scanner Access Now Easy) backend that +provides access to USB flatbed scanners based on National Semiconductor +Merlin chipsets (LM9831, 9832 and 9833). +If you're looking for parallel-port support for Plustek scanner +please refer to the +.B sane\-plustek_pp +backend. + +.SH "SUPPORTED DEVICES" +The Backend is able to support USB scanner based on the National +Semiconductor chipsets LM9831, LM9832 and LM9833. The following tables +show various devices which are currently reported to work. If your +Plustek scanner has another Product ID, then the device is +.B NOT +supported by this backend. +.br + +Vendor Plustek \- ID: 0x07B3 +.br +.ft CR +.nf +---------------------------------------------------------- +USB Model: ASIC: Properties: Prod-ID +---------------------------------------------------------- +OpticPro U12 LM9831 600x1200dpi 42bit 512Kb 0x0010 +OpticPro UT12 LM9831 600x1200dpi 42bit 512Kb 0x0013 +OpticPro UT12 LM9832 600x1200dpi 42bit 512Kb 0x0017 +OpticPro UT16 LM9832 600x1200dpi 42bit 512Kb 0x0017 +OpticPro U24 LM9831 1200x2400dpi 42bit 2Mb 0x0011 +OpticPro U24 LM9832 1200x2400dpi 42bit 2Mb 0x0015 +OpticPro UT24 LM9832 1200x2400dpi 42bit 2Mb 0x0017 +.fi +.ft R +.PP + +Vendor KYE/Genius \- ID: 0x0458 +.br +.ft CR +.nf +---------------------------------------------------------- +USB Model: ASIC: Properties: Prod-ID +---------------------------------------------------------- +Colorpage HR6 V2 LM9832 600x1200dpi 42bit 512Kb 0x2007 +Colorpage HR6 V2 LM9832 600x1200dpi 42bit 512Kb 0x2008 +Colorpage HR6A LM9832 600x1200dpi 42bit 512Kb 0x2009 +Colorpage HR7 LM9832 600x1200dpi 42bit 512Kb 0x2013 +Colorpage HR7LE LM9832 600x1200dpi 42bit 512Kb 0x2015 +Colorpage HR6X LM9832 600x1200dpi 42bit 512Kb 0x2016 +.fi +.ft R +.PP + +Vendor Hewlett-Packard \- ID: 0x03F0 +.br +.ft CR +.nf +---------------------------------------------------------- +USB Model: ASIC: Properties: Prod-ID +---------------------------------------------------------- +ScanJet 2100C LM9831 600x1200dpi 42bit 512Kb 0x0505 +ScanJet 2200C LM9832 600x1200dpi 42bit 512Kb 0x0605 +.fi +.ft R +.PP + +Vendor Mustek \- ID: 0x0400 +.br +.ft CR +.nf +---------------------------------------------------------- +USB Model: ASIC: Properties: Prod-ID +---------------------------------------------------------- +BearPaw 1200 LM9831 600x1200dpi 42bit 512Kb 0x1000 +BearPaw 1200 LM9832 600x1200dpi 42bit 512Kb 0x1001* +BearPaw 2400 LM9832 1200x2400dpi 42bit 2Mb 0x1001 +.fi +.ft R +* see also description for model override switch below! +.PP + +Vendor UMAX \- ID: 0x1606 +.br +.ft CR +.nf +---------------------------------------------------------- +USB Model: ASIC: Properties: Prod-ID +---------------------------------------------------------- +UMAX 3400 LM9832 600x1200dpi 42bit 512Kb 0x0050 +UMAX 3400/3450 LM9832 600x1200dpi 42bit 512Kb 0x0060 +UMAX 5400 LM9832 1200x2400dpi 42bit 512Kb 0x0160 +.fi +.ft R +.PP + +Vendor COMPAQ \- ID: 0x049F +.br +.ft CR +.nf +---------------------------------------------------------- +USB Model: ASIC: Properties: Prod-ID +---------------------------------------------------------- +S4-100 LM9832 600x1200dpi 42bit 512Kb 0x001A +.fi +.ft R +.PP + +Vendor Epson \- ID: 0x04B8 +.br +.ft CR +.nf +---------------------------------------------------------- +USB Model: ASIC: Properties: Prod-ID +---------------------------------------------------------- +Perfection 1250 LM9832 1200x2400dpi 42bit 512Kb 0x010F +Perfection 1260 LM9832 1200x2400dpi 42bit 512Kb 0x011D +.fi +.ft R +.PP + +Vendor CANON \- ID: 0x04A9 +.br +.ft CR +.nf +---------------------------------------------------------- +USB Model: ASIC: Properties: Prod-ID +---------------------------------------------------------- +CanoScan N650/656U LM9832 600x1200dpi 42bit 512Kb 0x2206 +CanoScan N1220U LM9832 1200x2400dpi 42bit 512Kb 0x2207 +CanoScan D660U LM9832 600x1200dpi 42bit 512Kb 0x2208 +CanoScan N670/676U LM9833 600x1200dpi 48bit 512Kb 0x220D +CanoScan N1240U LM9833 1200x2400dpi 48bit 512Kb 0x220E +CanoScan LIDE20 LM9833 600x1200dpi 48bit 512Kb 0x220D +CanoScan LIDE25 LM9833 1200x2400dpi 48bit 512Kb 0x2220 +CanoScan LIDE30 LM9833 1200x2400dpi 48bit 512Kb 0x220E +.fi +.ft R +.PP + +Vendor Syscan \- ID: 0x0A82 +.br +.ft CR +.nf +---------------------------------------------------------- +USB Model: ASIC: Properties: Prod-ID +---------------------------------------------------------- +Travelscan 662 LM9833 600x1200dpi 48bit 512Kb 0x6620 +Travelscan 464 LM9833 600x1200dpi 48bit 512Kb 0x4600 +.fi +.ft R +.PP + +Vendor Portable Peripheral Co., Ltd. \- ID: 0x0A53 +.br +.ft CR +.nf +---------------------------------------------------------- +USB Model: ASIC: Properties: Prod-ID +---------------------------------------------------------- +Q-Scan USB001 LM9832 300x600dpi 42bit 512Kb 0x1000 +Q-Scan USB201 LM9832 300x600dpi 42bit 512Kb 0x2000 +.fi +.ft R +.PP + +Vendor Visioneer \- ID: 0x04A7 +.br +.ft CR +.nf +---------------------------------------------------------- +USB Model: ASIC: Properties: Prod-ID +---------------------------------------------------------- +Strobe XP100 LM9833 600x1200dpi 48bit 512Kb 0x0427 +.fi +.ft R +.PP + +.SH "OTHER PLUSTEK SCANNERS" +For parallelport device support see the +.B plustek_pp +backend. +.br +The SCSI scanner OpticPro 19200S is a rebadged Artec AM12S scanner +and is supported by the +.B Artec +backend. +.br +Only the National Semiconductor LM983[1/2/] based devices of Plustek +are supported by this backend. Older versions of the U12, the UT12, +the U1212 and U1248 (GrandTech chipset) are not supported. +.PP +.ft CR +.nf +Model Chipset backend +------------------------------------ +U1248 GrandTech gt68xx +UT16B GrandTech gt68xx +OpticSlim 1200 GrandTech gt68xx +OpticSlim 2400 GrandTech gt68xx +U12 P98003 u12 +UT12 P98003 u12 +1212U P98003 u12 +.fi +.ft R +For a more complete and up to date list see: +.B http://www.sane\-project.org/sane\-supported\-devices.html + +.SH "CONFIGURATION" +To use your scanner with this backend, you need at least two +entries in the configuration file +.I @CONFIGDIR@/plustek.conf +.RS +.I [usb] vendor-id product-id +.br +.I device /dev/usbscanner +.RE +.PP +.I [usb] +tells the backend, that the following devicename (here +.IR /dev/usbscanner ) +has to be interpreted as USB scanner device. If vendor- and +product-id has not been specified, the backend tries to +detect this by its own. If device is set to +.I auto +then the next matching device is used. +.br +The following options can be used for a default setup of +your device. Most of them are also available through +the frontend. +.PP +.B +The Options: +.PP +option warmup t +.RS +.I t +specifies the warmup period in seconds, if set to \-1, the +automatic warmup function will be used +.RE +.PP +option lampOff t +.RS +.I t +is the time in seconds for switching off the lamps in +standby mode +.RE +.PP +option lOffonEnd b +.RS +.I b +specifies the behaviour when closing the backend, 1 --> switch +lamps off, 0 --> do not change lamp status +.RE +.PP +option mov m +.RS +.I m +is the model override switch. It works only with Mustek +BearPaw devices. +.br +.br +.ft CR +.nf +m/PID | 0x1000 | 0x1001 +------+--------------+-------------- + 0 | BearPaw 1200 | BearPaw 2400 + 1 | no function | BearPaw 1200 +.fi +.ft R +.RE +.PP +option invertNegatives b +.RS +.I b +0 --> do not invert the picture during negativ scans, +.br +1 --> invert picture +.RE +.PP +option cacheCalData b +.RS +.I b +0 --> do not save calibration results, +.br +1 --> save results of calibration in ~/.sane/ directory +.RE +.PP +option altCalibration b +.RS +.I b +0 --> use standard calibration routines, +.br +1 --> use alternate calibration (only non Plustek devices, standard for CIS devices) +.RE +.PP +option skipFine b +.RS +.I b +0 --> perform fine calibration, +.br +1 --> skip fine calibration (only non Plustek devices) +.RE +.PP +option skipFineWhite b +.RS +.I b +0 --> perform white fine calibration, +.br +1 --> skip white fine calibration (only non Plustek devices) +.RE +.PP +option skipDarkStrip b +.RS +.I b +0 --> perform dark calibration, with enabled lamp using the +dark calibration strip of the scanner. If the scanner does +not have such a strip, the alternative way is to switch off +the lamp during this step. +.br +1 --> always switch off the lamp for dark calibration, even +a black strip is available +.RE +.PP +option skipCalibration b +.RS +.I b +0 --> perform calibration, +.br +1 --> skip calibration (only non Plustek devices) +.RE +.PP +option enableTPA b +.RS +.I b +0 --> default behaviour, specified by the internal tables, +.br +1 --> override internal tables and allow TPA mode (EPSON/UMAX only) +.RE + +.PP +option posOffX x +.br +option posOffY y +.br +option tpaOffX x +.br +option tpaOffY y +.br +option negOffX x +.br +option negOffY y +.RS +.I x y +By using this settings, the user can adjust the given image +positions. +.B Please note, that there's no internal range checking for +.B this feature. +.RE +.PP +option posShadingY p +.br +option tpaShadingY p +.br +option negShadingY p +.RS +.I p +overrides the internal shading position. The values are in steps. +.B Please note, that there's no internal range checking for +.B this feature. +.RE +.PP +option redGamma r +.br +option greenGamma g +.br +option blueGamma b +.br +option grayGamma gr +.RS +.I r g b gr +.RE +By using these values, the internal linear gamma table (r,g,b,gr = 1.0) +can be adjusted. +.PP +option red_gain r +.br +option red_offset ro +.br +option green_gain g +.br +option green_offset go +.br +option blue_gain b +.br +option blue_offset bo +.RS +.I r g b ro go bo +These values can be used to set the gain and offset values of +the AFE for each channel. The range is between 0 and 63. \-1 +means autocalibration. +.RE + +.PP +See the plustek.conf file for examples. +.PP +.B Note: +.br +You have to make sure, that the USB subsystem is loaded +correctly and you have access to the device-node. For +more details see +.B sane\-usb (5) +manpage. You might use +.B sane\-find\-scanner +to check that you have access to your device. +.PP +.B Note: +.br +If there's no configuration file, the backend defaults to +.B device auto + +.SH FILES +.TP +.I @CONFIGDIR@/plustek.conf +The backend configuration file +.TP +.I @LIBDIR@/libsane\-plustek.a +The static library implementing this backend. +.TP +.I @LIBDIR@/libsane\-plustek.so +The shared library implementing this backend (present on systems that +support dynamic loading). + +.SH ENVIRONMENT +.TP +.B SANE_CONFIG_DIR +This environment variable specifies the list of directories that may +contain the configuration file. Under UNIX, the directories are +separated by a colon (`:'), under OS/2, they are separated by a +semi-colon (`;'). If this variable is not set, the configuration file +is searched in two default directories: first, the current working +directory (".") and then in @CONFIGDIR@. If the value of the +environment variable ends with the directory separator character, then +the default directories are searched after the explicitly specified +directories. For example, setting +.B SANE_CONFIG_DIR +to "/tmp/config:" would result in directories "tmp/config", ".", and +"@CONFIGDIR@" being searched (in this order). +.TP +.B SANE_DEBUG_PLUSTEK +If the library was compiled with debug support enabled, this +environment variable controls the debug level for this backend. Higher +debug levels increase the verbosity of the output. + +Example: +export SANE_DEBUG_PLUSTEK=10 + +.SH "SEE ALSO" +.BR sane (7), +.BR sane\-usb (5), +.BR sane\-u12 (5), +.BR sane\-gt68xx (5), +.br +.I @DOCDIR@/plustek/Plustek-USB.changes +.br +.I http://www.gjaeger.de/scanner/plustek/ + +.SH "CONTACT AND BUG-REPORTS" +Please send any information and bug-reports to: +.br +.B SANE Mailing List +.PP +Additional info and hints can be obtained from our +.br +Mailing-List archive at: +.br +.B http://www.sane\-project.org/mailing\-lists.html +.PP +or directly from the projects' homepage at: +.br +.B http://www.gjaeger.de/scanner/plustek/ +.PP +To obtain debug messages from the backend, please set the +environment-variable +.I SANE_DEBUG_PLUSTEK +before calling your favorite scan-frontend (i.e. xscanimage). +.br +.B i.e.: export SANE_DEBUG_PLUSTEK=20 ; xscanimage +.PP +The value controls the verbosity of the backend. Please note, that +values greater than 24 force the backend to output raw data files, +which could be rather large. The ending of these files is ".raw". +For problem reports it should be enough the set the verbosity to +13. + +.SH "KNOWN BUGS & RESTRICTIONS" + +.PP +* The driver does not support these manic scalings up +to 16 times the physical resolution. The only scaling +is done on resolutions between the physical resolution +of the CCD-/CIS-sensor and the stepper motor i.e. you +have a 600x1200 dpi scanner and you are scanning using +800dpi, so scaling is necessary, because the sensor only +delivers 600dpi but the motor is capable to perform +1200dpi steps. +.PP +* Plusteks' model policy is somewhat inconsistent. They +sell technically different devices under the +same product name. Therefore it is possible that some +devices like the UT12 or U12 won't work \- please check +the model list above and compare the product-id to +the one your device has. +.PP +* Negative/Slide scanning quality is poor. |