diff options
author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2019-07-31 17:00:20 +0200 |
---|---|---|
committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2019-07-31 17:00:20 +0200 |
commit | 3759ce55ba79b8d3b9d8ed247a252273ee7dade3 (patch) | |
tree | d69692a274dd1c7d0672e6bb7155a0fc106f9d49 /doc/sane-teco2.man | |
parent | c8bd2513ecba169cff44c09c8058c36987357b18 (diff) | |
parent | 1687222e1b9e74c89cafbb5910e72d8ec7bfd40f (diff) |
Update upstream source from tag 'upstream/1.0.28'
Update to upstream version '1.0.28'
with Debian dir ec5bb298266630fc3801ff6dc0c258f6df7ba979
Diffstat (limited to 'doc/sane-teco2.man')
-rw-r--r-- | doc/sane-teco2.man | 38 |
1 files changed, 19 insertions, 19 deletions
diff --git a/doc/sane-teco2.man b/doc/sane-teco2.man index 3abd3b8..4b79960 100644 --- a/doc/sane-teco2.man +++ b/doc/sane-teco2.man @@ -45,7 +45,7 @@ Note that the untested scanner will not be directly supported. You should contact the author for that. The TECO VM number can usually be found at the back of the -scanner. It is also part of the FCC ID. +scanner. It is also part of the FCC ID. The options the backend supports can either be selected through command line options to programs like scanimage or through GUI @@ -56,7 +56,7 @@ If you have any success with a scanner not listed here, or if you have any strange behavior, please report to the backend maintainer or to the SANE mailing list. -Valid command line options and their syntax can be listed by using +Valid command line options and their syntax can be listed by using .RS scanimage \-\-help \-d teco2 .RE @@ -66,7 +66,7 @@ scanimage \-\-help \-d teco2 .TP .B \-\-mode -selects the basic mode of operation of the scanner valid choices are +selects the basic mode of operation of the scanner valid choices are .I Lineart , .I Gray @@ -84,21 +84,21 @@ between 1 and 600, in increments of 1. Color -selects the resolution for a scan. The scanner can do only the +selects the resolution for a scan. The scanner can do only the resolutions listed. -All values with ydpi > 300 (300 x 600) or 600 (600 x 1200) result in -a wrong proportion for the scan. The proportion can be adjusted with -the following imagemagick command: -convert \-geometry (dpi/max_xdpi * 100%)x100% -max_xdpi is for the vm3575 constant with 300 dpi -e.g. 600dpi adjust with: convert \-geometry 200%x100% +All values with ydpi > 300 (300 x 600) or 600 (600 x 1200) result in +a wrong proportion for the scan. The proportion can be adjusted with +the following imagemagick command: +convert \-geometry (dpi/max_xdpi * 100%)x100% +max_xdpi is for the vm3575 constant with 300 dpi +e.g. 600dpi adjust with: convert \-geometry 200%x100% .TP .B Geometry options .TP -.B \-l \-t \-x \-y +.B \-l \-t \-x \-y control the scan area: \-l sets the top left x coordinate, \-t the top left y coordinate, \-x selects the width and \-y the height of the scan area. All parameters are specified in millimeters by default. @@ -112,25 +112,25 @@ area. All parameters are specified in millimeters by default. (color mode only) allows the user to specify a gamma table (see the next 3 parameters). -.TP -.B \-\-red\-gamma\-table +.TP +.B \-\-red\-gamma\-table (color mode only) can be used to download a user defined gamma table for the red channel. The table must be 256 bytes long. -.TP -.B \-\-green\-gamma\-table +.TP +.B \-\-green\-gamma\-table (color mode only) can be used to download a user defined gamma table for the green channel. The table must be 256 bytes long. .TP -.B \-\-blue\-gamma\-table +.B \-\-blue\-gamma\-table (color mode only) can be used to download a user defined gamma table for the blue channel. The table must be 256 bytes long. .TP .B \-\-white\-level\-r (VM3564, VM356A, VM3575 and VM6575 only) Selects what red radiance level should be -considered "white", when scanning some sheets by changing the calibration +considered "white", when scanning some sheets by changing the calibration value loaded into the scanner. Scale 0..64 in steps of 1. .TP @@ -145,10 +145,10 @@ value loaded into the scanner. Scale 0..64 in steps of 1. considered "white", when scanning some sheets by changing the calibration value loaded into the scanner. Scale 0..64 in steps of 1. -.TP +.TP .B \-\-preview requests a preview scan. The resolution used for that scan is 50 dpi -(for VM356A and VM6575 75 dpi) and the scan area is the maximum allowed. +(for VM356A and VM6575 75 dpi) and the scan area is the maximum allowed. The scan mode is user selected. The default is "no". |