diff options
author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2021-02-16 18:24:46 +0100 |
---|---|---|
committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2021-02-16 18:24:46 +0100 |
commit | ecaaf250cb33ff61f37a7b441f2337584a655350 (patch) | |
tree | 4303648095deff998ae20c2393b56db527742ac9 /doc/sane-umax1220u.man | |
parent | 5793a221e112fa49073de0137d6bfa750a61b0a1 (diff) | |
parent | 351b7328520c16730ceb46e5acae16038c42185e (diff) |
Update upstream source from tag 'upstream/1.0.32'
Update to upstream version '1.0.32'
with Debian dir 2c1111c59d9d68bcbf479a4a4de7697fe2de127f
Diffstat (limited to 'doc/sane-umax1220u.man')
-rw-r--r-- | doc/sane-umax1220u.man | 30 |
1 files changed, 17 insertions, 13 deletions
diff --git a/doc/sane-umax1220u.man b/doc/sane-umax1220u.man index a83db59..eea0e54 100644 --- a/doc/sane-umax1220u.man +++ b/doc/sane-umax1220u.man @@ -18,14 +18,14 @@ For more information on this backend, please visit This backend is also able to drive the UMAX Astra 1600U/2000U/2100U. The 2100U is confirmed to work. For the other scanners no reports have been received yet. Please contact us and tell us if your scanner works -(sane\-devel@alioth-lists.debian.net). +.RI ( sane\-devel@alioth-lists.debian.net ). .SH CONFIGURATION Usually, no manual configuration is necessary. The configuration file for this backend resides in .IR @CONFIGDIR@/umax1220u.conf . -Its contents is a list of device names that correspond to UMAX Astra scanners. +Its content is a list of device names that correspond to UMAX Astra scanners. Empty lines and lines starting with a hash mark (#) are ignored. A sample configuration file is shown below: @@ -37,8 +37,9 @@ configuration file is shown below: /dev/usb/scanner0 .fi -See sane\-usb(5) for information on how to set the access permissions on the usb -device files. +See +.BR sane\-usb (5) +for information on how to set the access permissions on the usb device files. .SH FILES @@ -61,7 +62,8 @@ If the library was compiled with debug support enabled, this environment variable controls the debug level for this backend. E.g., a value of 128 requests all debug output to be printed. Smaller levels reduce verbosity: -SANE_DEBUG_UMAX1220U values +.B SANE_DEBUG_UMAX1220U +values: .ft CR .nf @@ -88,29 +90,31 @@ export SANE_DEBUG_UMAX1220U=10 If you keep getting I/O errors, try cycling the power on your scanner to reset it. -There is no way to cancel a scan, since the driver ignores sane_cancel(). +There is no way to cancel a scan, since the driver ignores +.BR sane_cancel (). If you try scanning an image which is too small, you will get I/O errors. Be sure to adjust the scan area before doing a scan, since by default, the scan area is zero. .SH SEE ALSO -sane(7), sane\-usb(5) +.BR sane (7), +.BR sane\-usb (5) .TP (Old) homepage: .I http://umax1220u\-sane.sourceforge.net/ .SH AUTHOR - -Marcio Luis Teixeira <marciot@users.sourceforge.net> +Marcio Luis Teixeira +.RI < marciot@users.sourceforge.net > .SH EMAIL-CONTACT -sane\-devel@alioth-lists.debian.net +.I sane\-devel@alioth-lists.debian.net .SH REPORTING BUGS - This backend isn't actively maintained. Nevertheless, bug reports and comments should be sent to the sane\-devel mailing list. When reporting bugs, please run -the backend with SANE_DEBUG_UMAX1220U set to 10 and attach a copy of the log -messages. +the backend with +.B SANE_DEBUG_UMAX1220U +set to 10 and attach a copy of the log messages. |