diff options
Diffstat (limited to 'backend/snapscan-options.c')
-rw-r--r-- | backend/snapscan-options.c | 21 |
1 files changed, 10 insertions, 11 deletions
diff --git a/backend/snapscan-options.c b/backend/snapscan-options.c index 999b312..6bccf38 100644 --- a/backend/snapscan-options.c +++ b/backend/snapscan-options.c @@ -18,9 +18,7 @@ General Public License for more details. You should have received a copy of the GNU General Public License - along with this program; if not, write to the Free Software - Foundation, Inc., 59 Temple Place - Suite 330, Boston, - MA 02111-1307, USA. + along with this program. If not, see <https://www.gnu.org/licenses/>. As a special exception, the authors of SANE give permission for additional uses of the libraries contained in this release of SANE. @@ -44,10 +42,12 @@ If you do not wish that, delete this exception notice. This file is a component of the implementation of a backend for many - of the AGFA SnapScan and Acer Vuego/Prisa flatbed scanners. */ + of the AGFA SnapScan and Acer Vuego/Prisa flatbed scanners. +*/ -/* $Id$ - SANE SnapScan backend */ +/* + SANE SnapScan backend +*/ /* default option values */ @@ -1805,7 +1805,6 @@ SANE_Status sane_control_option (SANE_Handle h, } /* - * $Log$ * Revision 1.35 2006/01/06 20:59:17 oliver-guest * Some fixes for the Epson Stylus CX 1500 * @@ -1837,7 +1836,7 @@ SANE_Status sane_control_option (SANE_Handle h, * Fixes for Epson 3490 and 16 bit scan mode * * Revision 1.25 2005/09/28 22:09:26 oliver-guest - * Reenabled enhanced inquiry command for Epson scanners (duh\!) + * Re-enabled enhanced inquiry command for Epson scanners (duh\!) * * Revision 1.24 2005/09/28 21:33:10 oliver-guest * Added 16 bit option for Epson scanners (untested) @@ -1849,7 +1848,7 @@ SANE_Status sane_control_option (SANE_Handle h, * Added support for Epson 3490/3590 (thanks to Matt Judge) * * Revision 1.21 2005/07/20 21:37:29 oliver-guest - * Changed TPO scanning area for 2480/2580, reenabled 2400 DPI for 2480/2580 + * Changed TPO scanning area for 2480/2580, re-enabled 2400 DPI for 2480/2580 * * Revision 1.20 2005/05/22 11:50:24 oliver-guest * Disabled 2400 DPI for Epson 2480 @@ -1867,7 +1866,7 @@ SANE_Status sane_control_option (SANE_Handle h, * Use sanei_thread in snapscan backend * * Revision 1.15 2004/04/02 20:19:23 oliver-guest - * Various bugfixes for gamma corretion (thanks to Robert Tsien) + * Various bugfixes for gamma correction (thanks to Robert Tsien) * * Revision 1.14 2004/02/01 13:32:26 oliver-guest * Fixed resolutions for Epson 1670 @@ -1903,7 +1902,7 @@ SANE_Status sane_control_option (SANE_Handle h, * Disable quality calibration for 5300 * * Revision 1.5 2002/06/06 20:40:00 oliverschwartz - * Changed default scan area for transparancy unit of SnapScan e50 + * Changed default scan area for transparency unit of SnapScan e50 * * Revision 1.4 2002/05/02 18:28:44 oliverschwartz * Added ADF support |