diff options
Diffstat (limited to 'doc/gt68xx')
-rw-r--r-- | doc/gt68xx/gt68xx.CHANGES | 18 | ||||
-rw-r--r-- | doc/gt68xx/gt68xx.TODO | 6 |
2 files changed, 12 insertions, 12 deletions
diff --git a/doc/gt68xx/gt68xx.CHANGES b/doc/gt68xx/gt68xx.CHANGES index aa87504..074c1c9 100644 --- a/doc/gt68xx/gt68xx.CHANGES +++ b/doc/gt68xx/gt68xx.CHANGES @@ -80,7 +80,7 @@ V 1.0.73 (2005-08-19) V 1.0.72 (2005-08-18) * Finally fixed the problem concerning scanning on *BSD. Scanning only worked - once. After that, the scanner wasn't even detected anymore beacuse the config + once. After that, the scanner wasn't even detected anymore because the config descriptor returned by the device was corrupted. This is a hardware bug. When filling the internal memory of the scanner completely, the config descriptor is overwritten. The work-around is to ask the scanner for the device @@ -205,7 +205,7 @@ V 1.0-61 (2004-06-18) * Check for status of read_scanned_data every 10 ms. Avoids short stops before scan data comes in. * Added resolution limit for using backtracking. - * Reduced deafult CCD backtracking to 0x10 lines. + * Reduced default CCD backtracking to 0x10 lines. * CCD coarse calibration: * Check if calib has succeeded per color now (fewer loops). * Added loop detection now. @@ -399,7 +399,7 @@ V 1.0-40 (2003-02-22) - Added indormation about Medion 4394. - Mention ma1509 backend. - Fix segfault when calling sane_open with an empty device name. -- Explicitely initialize global variables to avoid segfaults when calling +- Explicitly initialize global variables to avoid segfaults when calling sane_init/sane_exit more than once. V 1.0-39 (2003-02-16) @@ -416,7 +416,7 @@ V 1.0-38 (2003-02-05) - Increase the lowest black for CCD coarse calibration to avoid too much black. - Adjusted internal gamma correction to avoid getting 0 for high gamma values. - CCD scanners use color mode for coarse+quality cal now. This fixes the - problem with extremly high gains and terrible quality cal in gray mode at + problem with extremely high gains and terrible quality cal in gray mode at least for the BearPaw 1200 TA. --> Thanks to Alexei V. Mezin for reporting these bugs. - Preview isn't always in 8 bit mode now (can be selected by option). @@ -533,8 +533,8 @@ V 1.0-26 (2002-10-22) - Several fixes for Medion MD-9385 and Artec Ultima 2000 based scanners. The Cytron MD 9385 works now. -- Diabled Plustek-like firmware check again, didn't work for MD 9385. -- Splitted flags for mirror_x and sset_home. +- Disabled Plustek-like firmware check again, didn't work for MD 9385. +- Split flags for mirror_x and sset_home. V 1.0-25 (2002-10-20) @@ -575,7 +575,7 @@ V 1.0-22 (2002-10-07), - Line calibration uses the bit depth of the main scan now. - Vendor, product ids and other information is printed when debugging is active - Fixed segfault in attach (). -- Fixed endianess issues (untested). +- Fixed endianness issues (untested). - Code cleanup. V 1.0-21 (2002-10-07), @@ -612,7 +612,7 @@ V 1.0-18 (2002-10-01) - Added detection of Artec Ultima 2000. - Updated Lexmark X70 settings. -- Fixed segfault that occured when no device was detected. +- Fixed segfault that occurred when no device was detected. - Changed test for loaded firmware for GT-6801 scanners. V 1.0-17 (2002-10-01) @@ -699,7 +699,7 @@ V 1.0-9 (2002-09-17) - Added option to disable automatic gain (->less ugly colors for GT-6801 based models) -- Fixed segfault that occured when a scan was cancelled +- Fixed segfault that occurred when a scan was cancelled - Preview uses slow but safe (?) 300 dpi 8 bit modes now - Fixed bug concerning X0/Y0 coordinates - Started implementing dpeth option (doesn't work yet) diff --git a/doc/gt68xx/gt68xx.TODO b/doc/gt68xx/gt68xx.TODO index 74aeb17..4909b08 100644 --- a/doc/gt68xx/gt68xx.TODO +++ b/doc/gt68xx/gt68xx.TODO @@ -33,7 +33,7 @@ Mustek BearPaw 2448 TA Plus: - Sometimes there is a USB protocol error when cancelling the scan? - top borders move with resolution (happened in the early days with 2400 TA!) - gray scans have different brightness -- scan motor is bumpy and freezes sometimes, looks like accelaration is too big +- scan motor is bumpy and freezes sometimes, looks like acceleration is too big (firmware problem?) - vertical stripes - TA settings are wrong @@ -93,7 +93,7 @@ Mustek ScanExpress 1248 UB ok Plustek OpticSlim 2400 -- only upto 1200 dpi vertical works +- only up to 1200 dpi vertical works - only 8 and 12 bit work, 16 doesn't (check Windows) - exposure is extremely high and seems to have similar problems as with other CIS scanners (reaches limit also) @@ -102,4 +102,4 @@ Mustek ScanExpress 2400 USB - make it work (nobody seems to have this device) Visioneer OneTouch 7300 -- 16 bit doesn't seem to work despite beeing advertized +- 16 bit doesn't seem to work despite being advertized |