summaryrefslogtreecommitdiff
path: root/doc/sane-coolscan.man
diff options
context:
space:
mode:
Diffstat (limited to 'doc/sane-coolscan.man')
-rw-r--r--doc/sane-coolscan.man111
1 files changed, 111 insertions, 0 deletions
diff --git a/doc/sane-coolscan.man b/doc/sane-coolscan.man
new file mode 100644
index 0000000..bf83014
--- /dev/null
+++ b/doc/sane-coolscan.man
@@ -0,0 +1,111 @@
+.TH sane\-coolscan 5 "13 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
+.IX sane\-coolscan
+
+.SH NAME
+sane\-coolscan \- SANE backend for Nikon film-scanners
+
+.SH ABOUT THIS FILE
+
+This file is a short description of the coolscan-backend for sane!
+
+.SH DESCRIPTION
+
+The
+.B sane\-coolscan
+library implements a SANE backend that provides the interface to the following Nikon Coolscan Film scanners: Nikon LS20, LS30, LS1000, LS2000.
+
+.B Even though the backend has worked for a number of people, there are still some problems, especially in combination with some SCSI card/drivers (AHA-1505/aha152x.o) and the autofocus command. You should consider this backend 'alpha' and be careful when using it the first time.
+
+.SH CONFIGURATION
+
+The configuration file for this backend resides in
+.IR @CONFIGDIR@/coolscan.conf .
+
+Its contents is a list of device names that correspond to Nikon Coolscan scanners. Empty lines
+and lines starting with a hash mark (#) are ignored. A sample configuration file is
+shown below:
+
+.nf
+ #scsi Vendor Model Type
+ scsi Nikon * Scanner
+ /dev/scanner
+.fi
+
+The special device name must be a generic SCSI device or a symlink to such a device.
+To find out to which device your scanner is assigned and how you have to set the
+permissions of that device, have a look at sane\-scsi.
+
+.SH SCSI ADAPTER TIPS
+
+Some SCSI-adapters and low-level SCSI drivers do not work correctly with this backend and the
+Coolscan scanners. These systems hang when the autofocus command is send to the Scanner.
+To see a list of which card/driver combinations work or dont work have a look at:
+http://andreas.rick.free.fr/sane/autofocus.html.
+
+
+
+.SH FILES
+
+.TP
+The backend configuration file:
+.I @CONFIGDIR@/coolscan.conf
+.TP
+The static library implementing this backend:
+.I @LIBDIR@/libsane\-coolscan.a
+.TP
+The shared library implementing this backend:
+.I @LIBDIR@/libsane\-coolscan.so
+(present on systems that support dynamic loading)
+
+.SH ENVIRONMENT
+
+.TP
+.B SANE_DEBUG_COOLSCAN
+If the library was compiled with debug support enabled, this environment
+variable controls the debug level for this backend. E.g., a value of 128
+requests all debug output to be printed. Smaller levels reduce verbosity:
+SANE_DEBUG_COOLSCAN values
+
+Examples:
+
+on bash:
+.br
+export SANE_DEBUG_COOLSCAN=8
+
+on csh:
+.br
+setenv SANE_DEBUG_COOLSCAN 8
+
+.SH BUGS
+
+The autofocus command does not work with some SCSI card/driver combinations
+.PP
+The gamma table is not implemented for the LS1000 yet.
+.PP
+The dust-removal is not working yet
+
+.SH SEE ALSO
+
+.TP
+.I http://andreas.rick.free.fr/sane/
+The homepage of this backend
+.TP
+.I http://www.sema.be/coolscan/
+The original version of the coolscan backend by Didier
+.PP
+sane(7), sane\-scsi(5)
+
+.SH THANKS TO
+
+.PP
+Didier Carlier \- For writing the original Coolscan backend (without it I would not have started this)
+.PP
+Oliver Rauch \- For adapting xsane so quickly to the infrared stuff.
+.PP
+All the other people working on SANE.
+
+.SH AUTHOR
+Andreas Rick
+
+.SH EMAIL-CONTACT
+andreas.rick@free.fr