diff options
Diffstat (limited to 'doc/sane-coolscan3.man')
-rw-r--r-- | doc/sane-coolscan3.man | 27 |
1 files changed, 13 insertions, 14 deletions
diff --git a/doc/sane-coolscan3.man b/doc/sane-coolscan3.man index 364d5ef..238f127 100644 --- a/doc/sane-coolscan3.man +++ b/doc/sane-coolscan3.man @@ -6,11 +6,11 @@ sane\-coolscan3 \- SANE backend for Nikon Coolscan film scanners The .B sane\-coolscan3 library implements a SANE (Scanner Access Now Easy) backend that -provides access to Nikon Coolscan film scanners. Some functions of this -backend should be considered +provides access to Nikon Coolscan film scanners. Some functions of this +backend should be considered .B beta-quality -software. Most functions have been stable for a long time, but of -course new development can not and will not function properly from +software. Most functions have been stable for a long time, but of +course new development can not and will not function properly from the very first day. .PP @@ -31,27 +31,27 @@ LS-8000 ED IEEE 1394 .ft R .RE -Please send mail to sane-devel@lists.alioth.debian.org to report successes +Please send mail to sane-devel@alioth-lists.debian.net to report successes or failures. .SH OPTIONS -The options the backend supports can either be selected through command line +The options the backend supports can either be selected through command line options to programs like scanimage or through GUI elements in xscanimage or xsane. -Valid command line options and their syntax can be listed by using +Valid command line options and their syntax can be listed by using .RS scanimage \-\-help \-d coolscan3:<interface>:<device> .RE where <interface> and <device> specify the device in question, as in the configuration file (see next section). The \-d parameter and its argument can be omitted to obtain information on the first scanner identified. Use -the command +the command .RS scanimage \-L .RE to list all devices recognized by your SANE installation. -The options should be fully described by the description or tooltips given by +The options should be fully described by the description or tooltips given by frontend. Here is a description of some of the most important options, in the syntax with which they must be supplied to scanimage: .TP @@ -69,7 +69,7 @@ unit is mm). .I \-\-infrared=yes/no If set to "yes", the scanner will read the infrared channel, thus allowing defect removal in software. The infrared image is read during a second scan, -with no options altered. The backend must not be restarted between the scans. +with no options altered. The backend must not be restarted between the scans. If you use scanimage, perform a batch scan with batch\-count=2 to obtain the IR information. .TP @@ -109,7 +109,7 @@ Eject the film strip or mounted slide when using the slide loader. Reset scanner. The scanner will perform the same action as when power is turned on: it will eject the film strip and calibrate itself. Use this whenever the scanner refuses to load a film strip properly, as a result of -which +which .I \-\-eject does not work. @@ -126,7 +126,7 @@ entries are case-sensitive: These lines are ignored, thus '#' can be used to include comments. .TP .I containing only the word """auto""" -This instructs the backend to probe for a scanner by scanning the buses for +This instructs the backend to probe for a scanner by scanning the buses for devices with know identifiers. This is the action taken when no configuration file is present. .TP @@ -178,5 +178,4 @@ No real bugs currently known, please report any to the SANE developers' list. .SH AUTHORS coolscan3 written by A. Zummo (a.zummo@towertech.it), based heavily on -coolscan2 written by Andr\['a]s Major (andras@users.sourceforge.net). - +coolscan2 written by Andr\['a]s Major (andras@users.sourceforge.net). |