summaryrefslogtreecommitdiff
path: root/doc/sane-plustek.man
diff options
context:
space:
mode:
Diffstat (limited to 'doc/sane-plustek.man')
-rw-r--r--doc/sane-plustek.man24
1 files changed, 9 insertions, 15 deletions
diff --git a/doc/sane-plustek.man b/doc/sane-plustek.man
index a6bb993..2df85b6 100644
--- a/doc/sane-plustek.man
+++ b/doc/sane-plustek.man
@@ -1,4 +1,4 @@
-.TH sane\-plustek 5 "13 Feb 2013" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
+.TH sane\-plustek 5 "03 Nov 2017" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
.IX sane\-plustek
.SH NAME
sane\-plustek \- SANE backend for LM983[1/2/3] based
@@ -241,7 +241,7 @@ The Options:
option warmup t
.RS
.I t
-specifies the warmup period in seconds, if set to \-1, the
+specifies the warmup period in seconds, if set to \-1, the
automatic warmup function will be used
.RE
.PP
@@ -468,8 +468,6 @@ export SANE_DEBUG_PLUSTEK=10
.BR sane\-gt68xx (5),
.br
.I @DOCDIR@/plustek/Plustek-USB.changes
-.br
-.I http://www.gjaeger.de/scanner/plustek/
.SH "CONTACT AND BUG-REPORTS"
Please send any information and bug-reports to:
@@ -482,16 +480,12 @@ Mailing-List archive at:
.br
.B http://www.sane\-project.org/mailing\-lists.html
.PP
-or directly from the projects' homepage at:
-.br
-.B http://www.gjaeger.de/scanner/plustek/
-.PP
To obtain debug messages from the backend, please set the
environment-variable
.I SANE_DEBUG_PLUSTEK
-before calling your favorite scan-frontend (i.e. xscanimage).
+before calling your favorite scan-frontend (i.e. scanimage).
.br
-.B i.e.: export SANE_DEBUG_PLUSTEK=20 ; xscanimage
+.B i.e.: export SANE_DEBUG_PLUSTEK=20 ; scanimage
.PP
The value controls the verbosity of the backend. Please note, that
values greater than 24 force the backend to output raw data files,
@@ -505,13 +499,13 @@ For problem reports it should be enough the set the verbosity to
* The driver does not support these manic scalings up
to 16 times the physical resolution. The only scaling
is done on resolutions between the physical resolution
-of the CCD-/CIS-sensor and the stepper motor i.e. you
-have a 600x1200 dpi scanner and you are scanning using
-800dpi, so scaling is necessary, because the sensor only
-delivers 600dpi but the motor is capable to perform
+of the CCD-/CIS-sensor and the stepper motor i.e. you
+have a 600x1200 dpi scanner and you are scanning using
+800dpi, so scaling is necessary, because the sensor only
+delivers 600dpi but the motor is capable to perform
1200dpi steps.
.PP
-* Plusteks' model policy is somewhat inconsistent. They
+* Plusteks' model policy is somewhat inconsistent. They
sell technically different devices under the
same product name. Therefore it is possible that some
devices like the UT12 or U12 won't work \- please check