Diffstat (limited to 'doc/sane-teco1.man')
-rw-r--r-- | doc/sane-teco1.man | 44 |
1 files changed, 22 insertions, 22 deletions
diff --git a/doc/sane-teco1.man b/doc/sane-teco1.man index acb4985..4f4ce85 100644 --- a/doc/sane-teco1.man +++ b/doc/sane-teco1.man @@ -20,21 +20,21 @@ The scanners that should work with this backend are: .nf Vendor Model TECO model status ---------------------- -------------- ----------- - Relisys AVEC 2400 VM3520 tested + Relisys AVEC 2400 VM3520 tested Relisys AVEC 2412 VM3520+ tested - Relisys AVEC 4800 VM4530 untested - Relisys AVEC 4816 VM4530+ untested - Relisys RELI 2400 VM3530 untested + Relisys AVEC 4800 VM4530 untested + Relisys AVEC 4816 VM4530+ untested + Relisys RELI 2400 VM3530 untested Relisys RELI 2412 VM3530+ tested - Relisys RELI 2412 VM3530+ untested - Relisys RELI 4816 VM4540 tested + Relisys RELI 2412 VM3530+ untested + Relisys RELI 4816 VM4540 tested Relisys RELI 4830 VM4542 tested - Relisys RELI 9600 VM6530 untested - Relisys RELI 9612 VM6530* untested - Relisys RELI 9624 VM6530+ untested - Relisys RELI 9630 VM6540 untested - Relisys RELI DS15 VM3440 untested - Relisys RELI DS6 VM3420 untested + Relisys RELI 9600 VM6530 untested + Relisys RELI 9612 VM6530* untested + Relisys RELI 9624 VM6530+ untested + Relisys RELI 9630 VM6540 untested + Relisys RELI DS15 VM3440 untested + Relisys RELI DS6 VM3420 untested Dextra DF-600P VM3510 tested Dextra DF-4830T VM4542 untested Dextra DF-1200T+ VM3530+ untested @@ -59,7 +59,7 @@ If you have any success with a scanner not listed here, or if you have any strange behavior, please report to the backend maintainer or to the SANE mailing list. -Valid command line options and their syntax can be listed by using +Valid command line options and their syntax can be listed by using .RS scanimage \-\-help \-d teco1 .RE @@ -69,7 +69,7 @@ scanimage \-\-help \-d teco1 .TP .B \-\-mode -selects the basic mode of operation of the scanner valid choices are +selects the basic mode of operation of the scanner valid choices are .I Black & White , .I Grayscale @@ -89,7 +89,7 @@ between 1 and 600, in increments of 1. .B Geometry options .TP -.B \-l \-t \-x \-y +.B \-l \-t \-x \-y control the scan area: \-l sets the top left x coordinate, \-t the top left y coordinate, \-x selects the width and \-y the height of the scan area. All parameters are specified in millimeters by default. @@ -103,24 +103,24 @@ area. All parameters are specified in millimeters by default. (color mode only) allows the user to specify a gamma table (see the next 3 parameters). -.TP -.B \-\-red\-gamma\-table +.TP +.B \-\-red\-gamma\-table (color mode only) can be used to download a user defined gamma table for the red channel. The table must be 256 bytes long. -.TP -.B \-\-green\-gamma\-table +.TP +.B \-\-green\-gamma\-table (color mode only) can be used to download a user defined gamma table for the green channel. The table must be 256 bytes long. .TP -.B \-\-blue\-gamma\-table +.B \-\-blue\-gamma\-table (color mode only) can be used to download a user defined gamma table for the blue channel. The table must be 256 bytes long. .TP .B \-\-dither -(Black & White only) select the dither mask to use. Possible values are +(Black & White only) select the dither mask to use. Possible values are .I Line art , .I 2x2 @@ -140,7 +140,7 @@ and .I 8x8 vertical -.TP +.TP .B \-\-preview requests a preview scan. The resolution used for that scan is 22 dpi and the scan area is the maximum allowed. The scan mode is user |