summaryrefslogtreecommitdiff
path: root/doc/sane-teco2.man
diff options
context:
space:
mode:
Diffstat (limited to 'doc/sane-teco2.man')
-rw-r--r--doc/sane-teco2.man229
1 files changed, 229 insertions, 0 deletions
diff --git a/doc/sane-teco2.man b/doc/sane-teco2.man
new file mode 100644
index 0000000..3abd3b8
--- /dev/null
+++ b/doc/sane-teco2.man
@@ -0,0 +1,229 @@
+.TH sane\-teco2 5 "14 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
+.IX sane\-teco2
+.SH NAME
+sane\-teco2 \- SANE backend for TECO / RELISYS scanners
+.SH DESCRIPTION
+The
+.B sane\-teco2
+library implements a SANE (Scanner Access Now Easy) backend that
+provides access to some TECO SCSI flatbed scanners. This backend
+should be considered
+.B beta-quality
+software! TECO scanners are sold under
+various brands like Mustek, Relisys, Piotech, Primax, TRUST.
+This backend may or may not support yours.
+.PP
+The scanners that should work with this backend are:
+.PP
+.RS
+.ft CR
+.nf
+ Vendor Model TECO model status
+---------------------- -------------- -----------
+ Mustek ScanMagic 4830S VM3575 untested
+ Primax Jewel 4800 VM356A good
+ Primax Profi 9600 VM6575 basic
+ Primax Profi 19200 VM6586 good
+ Relisys APOLLO Express 3 VM356A basic
+ Relisys APOLLO Express 6 VM6565 good
+ Relisys APOLLO Express 12 ? untested
+ Relisys AVEC II S3 VM3564 good
+ Relisys AVEC Super 3 VM3575 basic
+ Relisys SCORPIO Pro VM6575 good
+ Relisys SCORPIO Pro-S VM6586 untested
+ Relisys SCORPIO Super 3 VM3575 good
+.fi
+.ft R
+.RE
+
+For all these scanners, lineart and gray mode work
+well. However, most of them do not support more than a handful of
+resolutions in color mode. See the backend home page (under AUTHOR)
+for the exact status of each scanner.
+
+Note that the untested scanner will not be directly supported. You
+should contact the author for that.
+
+The TECO VM number can usually be found at the back of the
+scanner. It is also part of the FCC ID.
+
+The options the backend supports can either be selected through
+command line options to programs like scanimage or through GUI
+elements in xscanimage, xsane, quiteinsane or kooka.
+
+.br
+If you have any success with a scanner not listed here, or if you have
+any strange behavior, please report to the backend maintainer or to
+the SANE mailing list.
+
+Valid command line options and their syntax can be listed by using
+.RS
+scanimage \-\-help \-d teco2
+.RE
+
+.TP
+.B Scan Mode
+
+.TP
+.B \-\-mode
+selects the basic mode of operation of the scanner valid choices are
+.I Lineart
+,
+.I Gray
+and
+.I Color
+The Lineart mode is black and white only (1 bit). Gray mode
+will produce 256 levels of gray (8 bits). Color will produce a 24 bits
+color image.
+
+.TP
+.B \-\-resolution
+Lineart and Gray
+selects the resolution for a scan. The scanner can do all resolutions
+between 1 and 600, in increments of 1.
+
+
+Color
+selects the resolution for a scan. The scanner can do only the
+resolutions listed.
+
+All values with ydpi > 300 (300 x 600) or 600 (600 x 1200) result in
+a wrong proportion for the scan. The proportion can be adjusted with
+the following imagemagick command:
+convert \-geometry (dpi/max_xdpi * 100%)x100%
+max_xdpi is for the vm3575 constant with 300 dpi
+e.g. 600dpi adjust with: convert \-geometry 200%x100%
+
+.TP
+.B Geometry options
+
+.TP
+.B \-l \-t \-x \-y
+control the scan area: \-l sets the top left x coordinate, \-t the top
+left y coordinate, \-x selects the width and \-y the height of the scan
+area. All parameters are specified in millimeters by default.
+
+
+.TP
+.B Enhancement options
+
+.TP
+.B \-\-custom\-gamma (no custom gamma option for the VM3564 and VM356A)
+(color mode only) allows the user to specify a gamma table (see the
+next 3 parameters).
+
+.TP
+.B \-\-red\-gamma\-table
+(color mode only) can be used to download a user defined
+gamma table for the red channel. The table must be 256 bytes long.
+
+.TP
+.B \-\-green\-gamma\-table
+(color mode only) can be used to download a user defined
+gamma table for the green channel. The table must be 256 bytes long.
+
+.TP
+.B \-\-blue\-gamma\-table
+(color mode only) can be used to download a user defined gamma table
+for the blue channel. The table must be 256 bytes long.
+
+.TP
+.B \-\-white\-level\-r
+(VM3564, VM356A, VM3575 and VM6575 only) Selects what red radiance level should be
+considered "white", when scanning some sheets by changing the calibration
+value loaded into the scanner. Scale 0..64 in steps of 1.
+
+.TP
+.B \-\-white\-level\-g
+(VM3564, VM356A, VM3575 and VM6575 only) Selects what green radiance level should be
+considered "white", when scanning some sheets by changing the calibration i
+value loaded into the scanner. Scale 0..64 in steps of 1.
+
+.TP
+.B \-\-white\-level\-b
+(VM3564, VM356A, VM3575 and VM6575 only) Selects what blue radiance level should be
+considered "white", when scanning some sheets by changing the calibration
+value loaded into the scanner. Scale 0..64 in steps of 1.
+
+.TP
+.B \-\-preview
+requests a preview scan. The resolution used for that scan is 50 dpi
+(for VM356A and VM6575 75 dpi) and the scan area is the maximum allowed.
+The scan mode is user selected. The default is "no".
+
+
+.SH CONFIGURATION FILE
+The configuration file @CONFIGDIR@/teco2.conf supports only one
+information: the device name to use (eg /dev/scanner).
+
+
+.SH FILES
+.TP
+.I @LIBDIR@/libsane\-teco2.a
+The static library implementing this backend.
+.TP
+.I @LIBDIR@/libsane\-teco2.so
+The shared library implementing this backend (present on systems that
+support dynamic loading).
+
+
+.SH ENVIRONMENT
+.TP
+.B SANE_DEBUG_TECO2
+If the library was compiled with debug support enabled, this
+environment variable controls the debug level for this backend. E.g.,
+a value of 128 requests all debug output to be printed. Smaller levels
+reduce verbosity.
+.TP
+.B SANE_TECO2_CAL_ALGO
+Either 0 or 1. Selects the algorithm for the calibration. A
+value of 1 seems to give better scans on the VM356A, VM3575.
+Feedback on it is welcome.
+For VM3564, VM356A, VM3575, VM6575 default 1.
+For other supported types default 0.
+
+
+.SH LIMITATIONS
+The windows TWAIN driver has many more options than this SANE
+backend. However they are only software adjustments. This backend only
+implements what the scanner can support.
+
+
+.SH BUGS
+
+Plenty. Parts of this backend are still under development.
+
+
+.SH "SEE ALSO"
+
+sane\-scsi(5), scanimage(1), xscanimage(1), xsane(1), sane(7)
+
+
+.SH AUTHORS
+.TP
+Frank Zago
+.I http://www.zago.net/sane/#teco2
+.TP
+The package is actively maintained by Gerard Klaver.
+.I http://gkall.hobby.nl/teco2.html
+
+
+
+
+.SH CREDITS
+
+Thanks to:
+.TP
+Gerard Klaver for his relentless VM3575 testings and contributed a patch to support the VM3564 and VM356A.
+.TP
+Mark Plowman for providing the first SCSI traces from a VM3575.
+.TP
+Andreas Klaedtke for providing the first SCSI traces from a VM6586 and for his testing, and to Stefan von Dombrowski for his testing.
+.TP
+Nicolas Peyresaubes for providing the first SCSI traces from a VM656A and for his testing.
+.TP
+Dave Parker for testing the support for the VM6575.
+.TP
+Michael Hoeller for testing the support for the VM356A.
+.TP
+Christoph.Hoeffner for testing the support for the VM3564 (Relisys AVEC II S3 firmware 1.09).