summaryrefslogtreecommitdiff
path: root/doc/sane-umax1220u.man
diff options
context:
space:
mode:
Diffstat (limited to 'doc/sane-umax1220u.man')
-rw-r--r--doc/sane-umax1220u.man30
1 files changed, 17 insertions, 13 deletions
diff --git a/doc/sane-umax1220u.man b/doc/sane-umax1220u.man
index a83db59..eea0e54 100644
--- a/doc/sane-umax1220u.man
+++ b/doc/sane-umax1220u.man
@@ -18,14 +18,14 @@ For more information on this backend, please visit
This backend is also able to drive the UMAX Astra 1600U/2000U/2100U. The
2100U is confirmed to work. For the other scanners no reports have been received
yet. Please contact us and tell us if your scanner works
-(sane\-devel@alioth-lists.debian.net).
+.RI ( sane\-devel@alioth-lists.debian.net ).
.SH CONFIGURATION
Usually, no manual configuration is necessary. The configuration file for this backend resides in
.IR @CONFIGDIR@/umax1220u.conf .
-Its contents is a list of device names that correspond to UMAX Astra scanners.
+Its content is a list of device names that correspond to UMAX Astra scanners.
Empty lines and lines starting with a hash mark (#) are ignored. A sample
configuration file is shown below:
@@ -37,8 +37,9 @@ configuration file is shown below:
/dev/usb/scanner0
.fi
-See sane\-usb(5) for information on how to set the access permissions on the usb
-device files.
+See
+.BR sane\-usb (5)
+for information on how to set the access permissions on the usb device files.
.SH FILES
@@ -61,7 +62,8 @@ If the library was compiled with debug support enabled, this environment
variable controls the debug level for this backend. E.g., a value of 128
requests all debug output to be printed. Smaller levels reduce verbosity:
-SANE_DEBUG_UMAX1220U values
+.B SANE_DEBUG_UMAX1220U
+values:
.ft CR
.nf
@@ -88,29 +90,31 @@ export SANE_DEBUG_UMAX1220U=10
If you keep getting I/O errors, try cycling the power on your scanner to reset it.
-There is no way to cancel a scan, since the driver ignores sane_cancel().
+There is no way to cancel a scan, since the driver ignores
+.BR sane_cancel ().
If you try scanning an image which is too small, you will get I/O errors. Be
sure to adjust the scan area before doing a scan, since by default, the scan
area is zero.
.SH SEE ALSO
-sane(7), sane\-usb(5)
+.BR sane (7),
+.BR sane\-usb (5)
.TP
(Old) homepage:
.I http://umax1220u\-sane.sourceforge.net/
.SH AUTHOR
-
-Marcio Luis Teixeira <marciot@users.sourceforge.net>
+Marcio Luis Teixeira
+.RI < marciot@users.sourceforge.net >
.SH EMAIL-CONTACT
-sane\-devel@alioth-lists.debian.net
+.I sane\-devel@alioth-lists.debian.net
.SH REPORTING BUGS
-
This backend isn't actively maintained. Nevertheless, bug reports and comments
should be sent to the sane\-devel mailing list. When reporting bugs, please run
-the backend with SANE_DEBUG_UMAX1220U set to 10 and attach a copy of the log
-messages.
+the backend with
+.B SANE_DEBUG_UMAX1220U
+set to 10 and attach a copy of the log messages.