summaryrefslogtreecommitdiff
path: root/doc
diff options
context:
space:
mode:
Diffstat (limited to 'doc')
-rw-r--r--doc/descriptions/canon_dr.desc95
-rw-r--r--doc/descriptions/epjitsu.desc19
-rw-r--r--doc/descriptions/epson.desc1
-rw-r--r--doc/descriptions/epson2.desc1254
-rw-r--r--doc/descriptions/fujitsu.desc36
-rw-r--r--doc/descriptions/genesys.desc8
-rw-r--r--doc/descriptions/kodakaio.desc2
-rw-r--r--doc/descriptions/pixma.desc182
-rw-r--r--doc/descriptions/unsupported.desc21
-rw-r--r--doc/releases.txt15
-rw-r--r--doc/sane-cardscan.man2
-rw-r--r--doc/sane-coolscan.man2
-rw-r--r--doc/sane-epjitsu.man13
-rw-r--r--doc/sane-epson.man4
-rw-r--r--doc/sane-epson2.man4
-rw-r--r--doc/sane-genesys.man22
-rw-r--r--doc/sane-gt68xx.man2
-rw-r--r--doc/sane-kodakaio.man2
-rw-r--r--doc/sane-pixma.man107
-rw-r--r--doc/sane-scsi.man2
-rw-r--r--doc/sane-test.man8
-rw-r--r--doc/sane-umax_pp.man4
-rw-r--r--doc/sane-usb.man2
-rw-r--r--doc/sane.man2
-rw-r--r--doc/saned.man2
25 files changed, 1552 insertions, 259 deletions
diff --git a/doc/descriptions/canon_dr.desc b/doc/descriptions/canon_dr.desc
index b69bdcc..406bbfb 100644
--- a/doc/descriptions/canon_dr.desc
+++ b/doc/descriptions/canon_dr.desc
@@ -11,9 +11,9 @@
:backend "canon_dr" ; name of backend
:url "http://www.thebility.com/canon/"
-:version "41" ; version of backend
+:version "47" ; version of backend
:manpage "sane-canon_dr" ; name of manpage (if it exists)
-:comment "Backend updated for SANE release 1.0.24, see sane-canon_dr manpage"
+:comment "Backend updated for SANE release 1.0.25, see sane-canon_dr manpage"
:devicetype :scanner ; start of a list of devices....
; other types: :stillcam, :vidcam,
; :meta, :api
@@ -226,8 +226,8 @@
:model "DR-7080C"
:interface "USB SCSI"
:usbid "0x04a9" "0x1604"
-:status :untested
-:comment "Please test!"
+:status :good
+:comment "ADF and flatbed work"
:model "DR-7090C"
:interface "USB SCSI"
@@ -265,37 +265,62 @@
:status :untested
:comment "Please test!"
+:model "DR-C120"
+:interface "USB"
+:usbid "0x1083" "0x1651"
+:status :untested
+
:model "DR-C125"
:interface "USB"
-;:usbid "0x1083" "0x"
+:usbid "0x1083" "0x1640"
:status :untested
:comment "Similar protocol to other canon_dr machines, but unsupported image format."
:model "DR-C130"
:interface "USB"
-;:usbid "0x1083" "0x"
+:usbid "0x1083" "0x164a"
:status :untested
-:model "DR-G1100"
+:model "DR-C225"
:interface "USB"
-;:usbid "0x1083" "0x"
+:usbid "0x1083" "0x1658"
+:status :untested
+
+:model "DR-F120"
+:interface "USB"
+:usbid "0x1083" "0x1654"
:status :untested
+:model "DR-G1100"
+:interface "USB"
+:usbid "0x1083" "0x1650"
+:status :good
+
:model "DR-G1130"
:interface "USB"
-;:usbid "0x1083" "0x"
+:usbid "0x1083" "0x164f"
:status :untested
:model "DR-M140"
:interface "USB"
-;:usbid "0x1083" "0x"
-:status :untested
+:usbid "0x1083" "0x163f"
+:status :good
:model "DR-M160"
:interface "USB"
+:usbid "0x1083" "0x163e"
+:status :good
+
+:model "DR-M160II"
+:interface "USB"
;:usbid "0x1083" "0x"
:status :untested
+:model "DR-M1060"
+:interface "USB"
+:usbid "0x1083" "0x1657"
+:status :untested
+
:model "P-150"
:interface "USB"
;:usbid "0x1083" "0x"
@@ -306,15 +331,63 @@
;:usbid "0x1083" "0x"
:status :untested
+:model "P-201"
+:interface "USB"
+:usbid "0x1083" "0x1652"
+:status :untested
+
+:model "DR-P208"
+:interface "USB"
+:usbid "0x1083" "0x164b"
+:status :untested
+:comment "Same as P-208?"
+
:model "P-208"
:interface "USB"
:usbid "0x1083" "0x164c"
:status :basic
:comment "All modes and resolutions working, but calibration is poor."
+:model "DR-P208II"
+:interface "USB"
+:usbid "0x1083" "0x165d"
+:status :untested
+
+:model "P-208II"
+:interface "USB"
+:usbid "0x1083" "0x165f"
+:status :untested
+
+:model "DR-P215"
+:interface "USB"
+:usbid "0x1083" "0x1641"
+:status :untested
+:comment "Same as P-215?"
+
:model "P-215"
:interface "USB"
:usbid "0x1083" "0x1646"
:status :basic
:comment "All modes and resolutions working, but calibration is poor. Card reader slot not working."
+:model "P-215"
+:interface "USB"
+:usbid "0x1083" "0x1647"
+:status :basic
+:comment "This is the same device as the 0x1646 P-215, but the mode switch on the scanner is in the wrong position, you must move the switch."
+
+:model "DR-P215II"
+:interface "USB"
+:usbid "0x1083" "0x1659"
+:status :untested
+
+:model "P-215II"
+:interface "USB"
+:usbid "0x1083" "0x165b"
+:status :untested
+
+:model "FSU-201"
+:interface "USB"
+:usbid "0x1083" "0x1648"
+:status :untested
+
diff --git a/doc/descriptions/epjitsu.desc b/doc/descriptions/epjitsu.desc
index 7c453df..630a1f7 100644
--- a/doc/descriptions/epjitsu.desc
+++ b/doc/descriptions/epjitsu.desc
@@ -11,9 +11,9 @@
:backend "epjitsu" ; name of backend
:url "http://www.thebility.com/epjitsu/"
-:version "20" ; version of backend
+:version "25" ; version of backend
:manpage "sane-epjitsu" ; name of manpage (if it exists)
-:comment "Backend updated for SANE release 1.0.21, see sane-epjitsu manpage"
+:comment "Backend updated for SANE release 1.0.25, see sane-epjitsu manpage"
:devicetype :scanner ; start of a list of devices....
; other types: :stillcam, :vidcam,
; :meta, :api
@@ -42,9 +42,9 @@
:model "ScanSnap S1100"
:interface "USB"
-:status :unsupported
+:status :good
:usbid "0x04c5" "0x1200"
-:comment "Beta version of backend source available, which works well, but breaks support for other epjitsu scanners. See http://ubuntuforums.org/showthread.php?t=1678335"
+:comment "Hardware only supports 300 and 600 dpi simplex color. Backend manufactures gray and binary modes."
:model "ScanSnap S1300"
:interface "USB"
@@ -52,3 +52,14 @@
:usbid "0x04c5" "0x11ed"
:comment "Same as S300, with different usb id"
+:model "ScanSnap S1300i"
+:interface "USB"
+:status :good
+:usbid "0x04c5" "0x128d"
+:comment "Similar to S1300."
+
+:model "fi-65F"
+:interface "USB"
+:status :basic
+;:usbid "0x04c5" "0x10c7"
+:comment "A6-size flatbed, 300/600 dpi, color/gray/binary."
diff --git a/doc/descriptions/epson.desc b/doc/descriptions/epson.desc
index a31fc84..d5fd896 100644
--- a/doc/descriptions/epson.desc
+++ b/doc/descriptions/epson.desc
@@ -176,6 +176,7 @@
:model "Expression 800"
:interface "SCSI"
:status :complete
+:scsi "EPSON" "Expression800" "processor"
:model "Expression 1600"
:interface "SCSI USB IEEE-1394"
diff --git a/doc/descriptions/epson2.desc b/doc/descriptions/epson2.desc
index 9d9461d..82030b1 100644
--- a/doc/descriptions/epson2.desc
+++ b/doc/descriptions/epson2.desc
@@ -43,6 +43,30 @@
:status :good
:comment "network interface probably supported"
+:model "AcuLaser MX20DN"
+:interface "USB"
+:usbid "0x04b8" "0x0866"
+:status :complete
+:comment "network interface probably supported<br>business all-in-one"
+
+:model "AcuLaser MX20DNF"
+:interface "USB"
+:usbid "0x04b8" "0x0866"
+:status :complete
+:comment "network interface probably supported<br>business all-in-one"
+
+:model "AcuLaser MX21DNF"
+:interface "USB"
+:usbid "0x04b8" "0x0866"
+:status :complete
+:comment "network interface probably supported<br>business all-in-one"
+
+:model "Artisan 635"
+:interface "USB"
+:usbid "0x04b8" "0x0878"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-704A"
+
:model "Artisan 700"
:interface "USB Network"
:usbid "0x04b8" "0x0846"
@@ -52,8 +76,20 @@
:model "Artisan 710 Series"
:interface "USB"
:usbid "0x04b8" "0x0852"
-:status :unsupported
-:comment "supported by the epkowa backend plus non-free interpreter"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-802A"
+
+:model "Artisan 725"
+:interface "USB"
+:usbid "0x04b8" "0x0861"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-803A"
+
+:model "Artisan 730 Series"
+:interface "USB"
+:usbid "0x04b8" "0x087b"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-804A"
:model "Artisan 800"
:interface "USB"
@@ -64,8 +100,20 @@
:model "Artisan 810 Series"
:interface "USB"
:usbid "0x04b8" "0x0853"
-:status :unsupported
-:comment "supported by the epkowa backend plus non-free interpreter"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-902A"
+
+:model "Artisan 835"
+:interface "USB"
+:usbid "0x04b8" "0x0860"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-903A"
+
+:model "Artisan 837"
+:interface "USB"
+:usbid "0x04b8" "0x0879"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-904F"
:model "CC-500L" ; product spec (JP)
:interface "USB"
@@ -97,12 +145,54 @@
:status :unsupported
:comment "all-in-one"
-:model "EP-702A"
+:model "DS-30"
:interface "USB"
-:usbid "0x04b8" "0x0850"
+:usbid "0x04b8" "0x0147"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
+:model "EP-702A"
+:interface "USB"
+:usbid "0x04b8" "0x0850"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-703A"
+:interface "USB"
+:usbid "0x04b8" "0x0862"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-704A"
+:interface "USB"
+:usbid "0x04b8" "0x0878"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-705A"
+:interface "USB"
+:usbid "0x04b8" "0x089f"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-774A"
+:interface "USB"
+:usbid "0x04b8" "0x0893"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-775A"
+:interface "USB"
+:usbid "0x04b8" "0x089e"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-775AW"
+:interface "USB"
+:usbid "0x04b8" "0x089e"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
:model "EP-801A"
:interface "USB Network"
:usbid "0x04b8" "0x0846"
@@ -112,8 +202,56 @@
:model "EP-802A"
:interface "USB"
:usbid "0x04b8" "0x0852"
-:status :unsupported
-:comment "supported by the epkowa backend plus non-free interpreter"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-803A"
+:interface "USB"
+:usbid "0x04b8" "0x0861"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-803AW"
+:interface "USB"
+:usbid "0x04b8" "0x0861"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-804A"
+:interface "USB"
+:usbid "0x04b8" "0x087b"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-804AR"
+:interface "USB"
+:usbid "0x04b8" "0x087b"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-804AW"
+:interface "USB"
+:usbid "0x04b8" "0x087b"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-805A"
+:interface "USB"
+:usbid "0x04b8" "0x089c"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-805AR"
+:interface "USB"
+:usbid "0x04b8" "0x089c"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-805AW"
+:interface "USB"
+:usbid "0x04b8" "0x089c"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
:model "EP-901A"
:interface "USB"
@@ -130,8 +268,44 @@
:model "EP-902A"
:interface "USB"
:usbid "0x04b8" "0x0853"
-:status :unsupported
-:comment "supported by the epkowa backend plus non-free interpreter"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-903A"
+:interface "USB"
+:usbid "0x04b8" "0x0860"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-903F"
+:interface "USB"
+:usbid "0x04b8" "0x0860"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-904A"
+:interface "USB"
+:usbid "0x04b8" "0x0879"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-904F"
+:interface "USB"
+:usbid "0x04b8" "0x0879"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-905A"
+:interface "USB"
+:usbid "0x04b8" "0x089b"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "EP-905F"
+:interface "USB"
+:usbid "0x04b8" "0x089a"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
:model "ES-300C"
:interface "SCSI parallel"
@@ -214,12 +388,28 @@
:status :good
:comment "network interface unsupported<br>IEEE1394 untested"
+:model "ES-D200"
+:interface "USB"
+:usbid "0x04b8" "0x0137"
+:status :unsupported
+:comment "supported by the epkowa backend plus non-free interpreter"
+
+:model "ES-D350"
+:interface "USB"
+:usbid "0x04b8" "0x0144"
+:status :unsupported
+:comment "supported by the epkowa backend plus non-free interpreter"
+
:model "ES-D400"
:interface "USB"
:usbid "0x04b8" "0x0136"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
+
+:model "ES-G11000"
+:interface "USB"
+:usbid "0x04b8" "0x014b"
+:status :good
:model "ES-H300"
:interface "USB"
@@ -230,8 +420,8 @@
:model "ES-H7200"
:interface "USB Ethernet"
:usbid "0x04b8" "0x0138"
-:status :unsupported
-:comment "supported by the epkowa backend plus non-free interpreter"
+:status :good
+:comment "network interface supported via DFSG non-free iscan-network-nt package"
:model "Expression 636"
:interface "SCSI"
@@ -291,6 +481,12 @@
:status :untested
:comment "network interface probably supported"
+:model "Expression 11000XL"
+:interface "USB"
+:usbid "0x04b8" "0x014b"
+:status :good
+:comment "overseas version of the ES-G11000"
+
:model "F-3200" ; product spec (JP)
:interface "USB IEEE1394"
:usbid "0x04b8" "0x080a"
@@ -311,7 +507,6 @@
:usbid "0x04b8" "0x0133"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-2200"
:interface "USB"
@@ -372,14 +567,12 @@
:usbid "0x04b8" "0x010f"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-7300U" ; product spec (JP)
:interface "USB"
:usbid "0x04b8" "0x011d"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-7400U" ; product spec (JP)
:interface "USB"
@@ -461,7 +654,6 @@
:usbid "0x04b8" "0x0116"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-9500"
:interface "SCSI"
@@ -472,16 +664,14 @@
:status :complete
:model "GT-9700F" ; product spec (JP)
-:interface "USB"
+:interface "USB IEEE1394"
:usbid "0x04b8" "0x0112"
:status :complete
-:comment "IEEE1394 untested"
:model "GT-9800F" ; product spec (JP)
-:interface "USB"
+:interface "USB IEEE1394"
:usbid "0x04b8" "0x011c"
:status :complete
-:comment "IEEE1394 untested"
:model "GT-10000"
:interface "SCSI"
@@ -490,7 +680,6 @@
:model "GT-10000+" ; command spec
:interface "SCSI"
-:scsi "EPSON" "SCANNER GT-10000" "processor"
:status :good
:comment "IEEE1394 untested<br>overseas version of the ES-6000H"
@@ -508,8 +697,8 @@
:model "GT-20000"
:interface "USB Ethernet"
:usbid "0x04b8" "0x0138"
-:status :unsupported
-:comment "supported by the epkowa backend plus non-free interpreter"
+:status :good
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>overseas version of the ES-H7200"
:model "GT-30000" ; command spec
:interface "SCSI"
@@ -521,98 +710,120 @@
:usbid "0x04b8" "0x0133"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-F500" ; product spec (JP)
:interface "USB"
:usbid "0x04b8" "0x0121"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-F520"
:interface "USB"
:usbid "0x04b8" "0x0122"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-F550" ; product spec (JP)
:interface "USB"
:usbid "0x04b8" "0x0121"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-F570"
:interface "USB"
:usbid "0x04b8" "0x0122"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-F600" ; product spec (JP)
:interface "USB"
:usbid "0x04b8" "0x0118"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-F650"
:interface "USB"
:usbid "0x04b8" "0x012d"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-F670"
:interface "USB"
:usbid "0x04b8" "0x012e"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-F700"
:interface "USB"
:usbid "0x04b8" "0x012f"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-F720"
:interface "USB"
:usbid "0x04b8" "0x0131"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
+
+:model "GT-F730"
+:interface "USB"
+:usbid "0x04b8" "0x0142"
+:status :unsupported
+:comment "supported by the epkowa backend plus non-free interpreter"
+
+:model "GT-F740"
+:interface "USB"
+:usbid "0x04b8" "0x014a"
+:status :unsupported
+:comment "supported by the epkowa backend plus non-free interpreter"
:model "GT-S50"
:interface "USB"
:usbid "0x04b8" "0x0137"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
+
+:model "GT-S55"
+:interface "USB"
+:usbid "0x04b8" "0x0143"
+:status :unsupported
+:comment "supported by the epkowa backend plus non-free interpreter"
:model "GT-S80"
:interface "USB"
:usbid "0x04b8" "0x0136"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
+
+:model "GT-S85"
+:interface "USB"
+:usbid "0x04b8" "0x0144"
+:status :unsupported
+:comment "supported by the epkowa backend plus non-free interpreter"
:model "GT-S600"
:interface "USB"
:usbid "0x04b8" "0x012d"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-S620"
:interface "USB"
:usbid "0x04b8" "0x0131"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
+
+:model "GT-S630"
+:interface "USB"
+:usbid "0x04b8" "0x0142"
+:status :unsupported
+:comment "supported by the epkowa backend plus non-free interpreter"
+
+:model "GT-S640"
+:interface "USB"
+:usbid "0x04b8" "0x014a"
+:status :unsupported
+:comment "supported by the epkowa backend plus non-free interpreter"
:model "GT-X700" ; product spec (JP)
:interface "USB"
@@ -625,14 +836,12 @@
:usbid "0x04b8" "0x0119"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-X770"
:interface "USB"
:usbid "0x04b8" "0x0130"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-X800" ; product spec (JP)
:interface "USB"
@@ -645,7 +854,6 @@
:usbid "0x04b8" "0x013a"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "GT-X900"
:interface "USB"
@@ -659,6 +867,60 @@
:status :good
:comment "IEEE1394 untested"
+:model "K200 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0871"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "K300 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0872"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "L200 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0873"
+:status :complete
+:comment "all-in-one"
+
+:model "L210 Series"
+:interface "USB"
+:usbid "0x04b8" "0x08a1"
+:status :complete
+:comment "all-in-one"
+
+:model "L350"
+:interface "USB"
+:usbid "0x04b8" "0x08a1"
+:status :complete
+:comment "all-in-one"
+
+:model "L351"
+:interface "USB"
+:usbid "0x04b8" "0x08a1"
+:status :complete
+:comment "all-in-one"
+
+:model "L355"
+:interface "USB"
+:usbid "0x04b8" "0x08a8"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "L358"
+:interface "USB"
+:usbid "0x04b8" "0x08a8"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "L550"
+:interface "USB"
+:usbid "0x04b8" "0x08a9"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
:model "LP-7900CS"
:status :untested
:comment "business all-in-one; scanner is a ES-7000H"
@@ -711,6 +973,12 @@
:status :good
:comment "network interface probably supported<br>business all-in-one"
+:model "LP-M5300 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0894"
+:status :good
+:comment "network interface probably supported<br>business all-in-one"
+
:model "LP-M5500"
:interface "USB"
:usbid "0x04b8" "0x0817"
@@ -735,6 +1003,12 @@
:status :good
:comment "network interface probably supported<br>business all-in-one"
+:model "M200 Series"
+:interface "USB"
+:usbid "0x04b8" "0x08aa"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
:model "ME 200"
:interface "USB"
:usbid "0x04b8" "0x0830"
@@ -747,17 +1021,65 @@
:status :good
:comment "all-in-one<br>overseas version of the PX-401A"
+:model "ME 320 Series"
+:interface "USB"
+:usbid "0x04b8" "0x085c"
+:status :complete
+:comment "all-in-one"
+
+:model "ME 330 Series"
+:interface "USB"
+:usbid "0x04b8" "0x085c"
+:status :complete
+:comment "all-in-one"
+
+:model "ME 340 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0883"
+:status :complete
+:comment "all-in-one"
+
:model "ME OFFICE 510"
:interface "USB"
:usbid "0x04b8" "0x084f"
:status :good
:comment "all-in-one"
+:model "ME OFFICE 520 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0865"
+:status :complete
+:comment "all-in-one"
+
+:model "ME OFFICE 535"
+:interface "USB"
+:usbid "0x04b8" "0x0881"
+:status :complete
+:comment "all-in-one<br>overseas version of the PX-404A"
+
+:model "ME OFFICE 560W Series"
+:interface "USB"
+:usbid "0x04b8" "0x0864"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "ME OFFICE 570W Series"
+:interface "USB"
+:usbid "0x04b8" "0x0880"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-434A"
+
:model "ME Office 600F"
:interface "USB"
:usbid "0x04b8" "0x0848"
:status :good
-:comment "all-in-one"
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "ME OFFICE 620F Series"
+:interface "USB"
+:usbid "0x04b8" "0x0863"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
:model "ME OFFICE 650FN Series"
:interface "USB"
@@ -771,6 +1093,48 @@
:status :good
:comment "network interface probably supported<br>all-in-one<br>overseas version of the PX-601F"
+:model "ME OFFICE 900WD Series"
+:interface "USB"
+:usbid "0x04b8" "0x085e"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-503A"
+
+:model "ME OFFICE 940FW Series"
+:interface "USB"
+:usbid "0x04b8" "0x0890"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "ME OFFICE 960FWD Series"
+:interface "USB"
+:usbid "0x04b8" "0x085d"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "ME-101"
+:interface "USB"
+:usbid "0x04b8" "0x08a0"
+:status :complete
+:comment "all-in-one"
+
+:model "ME-301"
+:interface "USB"
+:usbid "0x04b8" "0x0896"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "ME-303"
+:interface "USB"
+:usbid "0x04b8" "0x0897"
+:status :complete
+:comment "all-in-one<br>overseas version of the PX-405A"
+
+:model "ME-401"
+:interface "USB"
+:usbid "0x04b8" "0x0898"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-435A"
+
:model "PM-A700" ; product spec (JP)
:interface "USB"
:usbid "0x04b8" "0x0814"
@@ -861,6 +1225,24 @@
:status :good
:comment "all-in-one<br>PM-A970 with network interface"
+:model "PX-045A"
+:interface "USB"
+:usbid "0x04b8" "0x0895"
+:status :complete
+:comment "all-in-one"
+
+:model "PX-1600F"
+:interface "USB"
+:usbid "0x04b8" "0x0869"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "PX-1700F"
+:interface "USB"
+:usbid "0x04b8" "0x087c"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
:model "PX-401A"
:interface "USB"
:usbid "0x04b8" "0x0841"
@@ -873,6 +1255,36 @@
:status :good
:comment "all-in-one"
+:model "PX-403A"
+:interface "USB"
+:usbid "0x04b8" "0x087f"
+:status :complete
+:comment "all-in-one"
+
+:model "PX-404A"
+:interface "USB"
+:usbid "0x04b8" "0x0881"
+:status :complete
+:comment "all-in-one"
+
+:model "PX-405A"
+:interface "USB"
+:usbid "0x04b8" "0x0897"
+:status :complete
+:comment "all-in-one"
+
+:model "PX-434A"
+:interface "USB"
+:usbid "0x04b8" "0x0880"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "PX-435A"
+:interface "USB"
+:usbid "0x04b8" "0x0898"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
:model "PX-501A"
:interface "USB"
:usbid "0x04b8" "0x084a"
@@ -885,12 +1297,66 @@
:status :good
:comment "all-in-one"
+:model "PX-503A"
+:interface "USB"
+:usbid "0x04b8" "0x085e"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "PX-504A"
+:interface "USB"
+:usbid "0x04b8" "0x0891"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "PX-505F"
+:interface "USB"
+:usbid "0x04b8" "0x08a5"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "PX-535F"
+:interface "USB"
+:usbid "0x04b8" "0x08a6"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
:model "PX-601F"
:interface "USB"
:usbid "0x04b8" "0x0847"
:status :good
:comment "network interface probably supported"
+:model "PX-602F"
+:interface "USB"
+:usbid "0x04b8" "0x0855"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "PX-603F"
+:interface "USB"
+:usbid "0x04b8" "0x085d"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "PX-605F"
+:interface "USB"
+:usbid "0x04b8" "0x0899"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "PX-673F"
+:interface "USB"
+:usbid "0x04b8" "0x086a"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "PX-675F"
+:interface "USB"
+:usbid "0x04b8" "0x0899"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
:model "PX-A550" ; product spec (JP)
:interface "USB"
:usbid "0x04b8" "0x080e"
@@ -927,6 +1393,12 @@
:status :good
:comment "all-in-one"
+:model "PX-B750F"
+:interface "USB"
+:usbid "0x04b8" "0x087d"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
:model "PX-FA700"
:interface "USB"
:usbid "0x04b8" "0x083a"
@@ -995,28 +1467,24 @@
:usbid "0x04b8" "0x010f"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection 1250 PHOTO"
:interface "USB"
:usbid "0x04b8" "0x010f"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection 1260"
:interface "USB"
:usbid "0x04b8" "0x011d"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection 1260 PHOTO"
:interface "USB"
:usbid "0x04b8" "0x011d"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection 1270"
:interface "USB"
@@ -1077,9 +1545,8 @@
:comment "overseas version of the GT-9300UF"
:model "Perfection 2450 PHOTO" ; command spec
-:interface "USB IEEE-1394"
+:interface "USB IEEE1394"
:usbid "0x04b8" "0x0112"
-:scsi "EPSON" "GT-9700" "processor"
:status :complete
:comment "overseas version of the GT-9700F"
@@ -1088,26 +1555,22 @@
:usbid "0x04b8" "0x0121"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection 2580 PHOTO"
:interface "USB"
:usbid "0x04b8" "0x0121"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection 3170 PHOTO"
:interface "USB"
:usbid "0x04b8" "0x0116"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection 3200 PHOTO" ; command spec
-:interface "USB IEEE-1394"
+:interface "USB IEEE1394"
:usbid "0x04b8" "0x011c"
-:scsi "EPSON" "GT-9800" "processor"
:status :complete
:comment "overseas version of the GT-9800F"
@@ -1116,28 +1579,24 @@
:usbid "0x04b8" "0x0122"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection 3590 PHOTO"
:interface "USB"
:usbid "0x04b8" "0x0122"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection 4180 PHOTO"
:interface "USB"
:usbid "0x04b8" "0x0118"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection 4490 PHOTO"
:interface "USB"
:usbid "0x04b8" "0x0119"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection 4870 PHOTO" ; command spec
:interface "USB"
@@ -1161,56 +1620,72 @@
:usbid "0x04b8" "0x012d"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection V30"
:interface "USB"
:usbid "0x04b8" "0x0131"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
+
+:model "Perfection V33"
+:interface "USB"
+:usbid "0x04b8" "0x0142"
+:status :unsupported
+:comment "supported by the epkowa backend plus non-free interpreter"
+
+:model "Perfection V37"
+:interface "USB"
+:usbid "0x04b8" "0x014a"
+:status :unsupported
+:comment "supported by the epkowa backend plus non-free interpreter"
:model "Perfection V100 Photo"
:interface "USB"
:usbid "0x04b8" "0x012d"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection V200 Photo"
:interface "USB"
:usbid "0x04b8" "0x012e"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection V300 Photo"
:interface "USB"
:usbid "0x04b8" "0x0131"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
+
+:model "Perfection V330 Photo"
+:interface "USB"
+:usbid "0x04b8" "0x0142"
+:status :unsupported
+:comment "supported by the epkowa backend plus non-free interpreter"
+
+:model "Perfection V370 Photo"
+:interface "USB"
+:usbid "0x04b8" "0x014a"
+:status :unsupported
+:comment "supported by the epkowa backend plus non-free interpreter"
:model "Perfection V350 Photo"
:interface "USB"
:usbid "0x04b8" "0x012f"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection V500 Photo"
:interface "USB"
:usbid "0x04b8" "0x0130"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection V600 Photo"
:interface "USB"
:usbid "0x04b8" "0x013a"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Perfection V700 Photo"
:interface "USB"
@@ -1312,14 +1787,12 @@
:usbid "0x04b8" "0x083f"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Stylus CX4400"
:interface "USB"
:usbid "0x04b8" "0x083f"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Stylus CX4500"
:interface "USB"
@@ -1386,14 +1859,12 @@
:usbid "0x04b8" "0x083f"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Stylus CX5600"
:interface "USB"
:usbid "0x04b8" "0x083f"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Stylus CX5700F"
:interface "USB"
@@ -1531,7 +2002,6 @@
:usbid "0x04b8" "0x083f"
:status :unsupported
:comment "supported by the epkowa backend plus non-free interpreter"
-:url "http://download.ebz.epson.net/dsc/search/01/search/?OSC=LX"
:model "Stylus DX4800"
:interface "USB"
@@ -1585,7 +2055,25 @@
:interface "USB"
:usbid "0x04b8" "0x0848"
:status :good
-:comment "all-in-one"
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "Stylus Office BX305F"
+:interface "USB"
+:usbid "0x04b8" "0x0863"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "Stylus Office BX305FW"
+:interface "USB"
+:usbid "0x04b8" "0x0863"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "Stylus Office BX305FW Plus"
+:interface "USB"
+:usbid "0x04b8" "0x0870"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
:model "Stylus Office BX310FN Series"
:interface "USB"
@@ -1593,6 +2081,30 @@
:status :good
:comment "all-in-one"
+:model "Stylus Office BX320FW Series"
+:interface "USB"
+:usbid "0x04b8" "0x085f"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "Stylus Office BX535WD"
+:interface "USB"
+:usbid "0x04b8" "0x0891"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>overseas version of the PX-504A"
+
+:model "Stylus Office BX630FW Series"
+:interface "USB"
+:usbid "0x04b8" "0x0890"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "Stylus Office BX525WD"
+:interface "USB"
+:usbid "0x04b8" "0x085e"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-503A"
+
:model "Stylus Office BX600FW"
:interface "USB"
:usbid "0x04b8" "0x0847"
@@ -1602,14 +2114,44 @@
:model "Stylus Office BX610FW Series"
:interface "USB"
:usbid "0x04b8" "0x0855"
-:status :unsupported
-:comment "supported by the epkowa backend plus non-free interpreter"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-602F"
+
+:model "Stylus Office BX625FWD"
+:interface "USB"
+:usbid "0x04b8" "0x085d"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "Stylus Office BX635FWD"
+:interface "USB"
+:usbid "0x04b8" "0x088f"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "Stylus Office BX925FWD"
+:interface "USB"
+:usbid "0x04b8" "0x086a"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-673F"
+
+:model "Stylus Office BX935FWD"
+:interface "USB"
+:usbid "0x04b8" "0x0892"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
:model "Stylus Office TX300F"
:interface "USB"
:usbid "0x04b8" "0x0848"
:status :good
-:comment "all-in-one"
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "Stylus Office TX320F Series"
+:interface "USB"
+:usbid "0x04b8" "0x0863"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
:model "Stylus Office TX510FN Series"
:interface "USB"
@@ -1617,6 +2159,12 @@
:status :good
:comment "all-in-one"
+:model "Stylus Office TX525FW"
+:interface "USB"
+:usbid "0x04b8" "0x085f"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
:model "Stylus Office TX600FW"
:interface "USB"
:usbid "0x04b8" "0x0847"
@@ -1626,14 +2174,26 @@
:model "Stylus Office TX610FW Series"
:interface "USB"
:usbid "0x04b8" "0x0855"
-:status :unsupported
-:comment "supported by the epkowa backend plus non-free interpreter"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-602F"
+
+:model "Stylus Office TX620FWD Series"
+:interface "USB"
+:usbid "0x04b8" "0x085d"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
:model "Stylus Photo PX650 Series"
:interface "USB"
:usbid "0x04b8" "0x0850"
-:status :unsupported
-:comment "supported by the epkowa backend plus non-free interpreter"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-702A"
+
+:model "Stylus Photo PX660 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0862"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-703A"
:model "Stylus Photo PX700W"
:interface "USB Network"
@@ -1644,8 +2204,20 @@
:model "Stylus Photo PX710W Series"
:interface "USB"
:usbid "0x04b8" "0x0852"
-:status :unsupported
-:comment "supported by the epkowa backend plus non-free interpreter"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-802A"
+
+:model "Stylus Photo PX720WD Series"
+:interface "USB"
+:usbid "0x04b8" "0x0861"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-803A"
+
+:model "Stylus Photo PX730WD Series"
+:interface "USB"
+:usbid "0x04b8" "0x087b"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-804A"
:model "Stylus Photo PX800FW"
:interface "USB"
@@ -1656,8 +2228,20 @@
:model "Stylus Photo PX810FW Series"
:interface "USB"
:usbid "0x04b8" "0x0853"
-:status :unsupported
-:comment "supported by the epkowa backend plus non-free interpreter"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-902A"
+
+:model "Stylus Photo PX820FWD Series"
+:interface "USB"
+:usbid "0x04b8" "0x0860"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-903A"
+
+:model "Stylus Photo PX830FWD Series"
+:interface "USB"
+:usbid "0x04b8" "0x0879"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-904F"
:model "Stylus Photo RX420"
:interface "USB"
@@ -1794,8 +2378,8 @@
:model "Stylus Photo TX650 Series"
:interface "USB"
:usbid "0x04b8" "0x0850"
-:status :unsupported
-:comment "supported by the epkowa backend plus non-free interpreter"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-702A"
:model "Stylus Photo TX700W"
:interface "USB"
@@ -1806,8 +2390,20 @@
:model "Stylus Photo TX710W Series"
:interface "USB"
:usbid "0x04b8" "0x0852"
-:status :unsupported
-:comment "supported by the epkowa backend plus non-free interpreter"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-802A"
+
+:model "Stylus Photo TX720WD Series"
+:interface "USB"
+:usbid "0x04b8" "0x0861"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-803A"
+
+:model "Stylus Photo TX730WD Series"
+:interface "USB"
+:usbid "0x04b8" "0x087b"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-804A"
:model "Stylus Photo TX800FW"
:interface "USB"
@@ -1815,6 +2411,12 @@
:status :good
:comment "network interface probably supported<br>all-in-one<br>overseas version of the EP-901A"
+:model "Stylus Photo TX820FWD Series"
+:interface "USB"
+:usbid "0x04b8" "0x0860"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-903A"
+
:model "Stylus NX100"
:interface "USB"
:usbid "0x04b8" "0x0841"
@@ -1827,6 +2429,24 @@
:status :good
:comment "all-in-one<br>overseas version of the PX-402A"
+:model "Stylus NX125"
+:interface "USB"
+:usbid "0x04b8" "0x085c"
+:status :complete
+:comment "all-in-one"
+
+:model "Stylus NX127"
+:interface "USB"
+:usbid "0x04b8" "0x085c"
+:status :complete
+:comment "all-in-one"
+
+:model "Stylus NX130 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0883"
+:status :complete
+:comment "all-in-one"
+
:model "Stylus NX200"
:interface "USB"
:usbid "0x04b8" "0x0849"
@@ -1839,11 +2459,29 @@
:status :good
:comment "all-in-one"
-:model "Stylus NX300"
+:model "Stylus NX220 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0865"
+:status :complete
+:comment "all-in-one"
+
+:model "Stylus NX230 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0885"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "Stylus NX300 Series"
:interface "USB"
:usbid "0x04b8" "0x0848"
:status :good
-:comment "all-in-one"
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "Stylus NX330 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0880"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
:model "Stylus NX400"
:interface "USB"
@@ -1857,12 +2495,42 @@
:status :good
:comment "network interface probably supported<br>all-in-one"
+:model "Stylus NX420 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0864"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "Stylus NX430W Series"
+:interface "USB"
+:usbid "0x04b8" "0x0884"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
:model "Stylus NX510 Series"
:interface "USB"
:usbid "0x04b8" "0x0856"
:status :good
:comment "all-in-one<br>overseas version of the PX-502A"
+:model "Stylus NX530 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0891"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-504A"
+
+:model "Stylus NX625"
+:interface "USB"
+:usbid "0x04b8" "0x085e"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-503A"
+
+:model "Stylus NX635"
+:interface "USB"
+:usbid "0x04b8" "0x0891"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>overseas version of the PX-504A"
+
:model "Stylus SX100"
:interface "USB"
:usbid "0x04b8" "0x0841"
@@ -1878,7 +2546,13 @@
:model "Stylus SX125"
:interface "USB"
:usbid "0x04b8" "0x085c"
-:status :untested
+:status :complete
+:comment "all-in-one"
+
+:model "Stylus SX130 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0883"
+:status :complete
:comment "all-in-one"
:model "Stylus SX200"
@@ -1899,6 +2573,24 @@
:status :good
:comment "all-in-one"
+:model "Stylus SX218"
+:interface "USB"
+:usbid "0x04b8" "0x0865"
+:status :complete
+:comment "all-in-one"
+
+:model "Stylus SX230 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0881"
+:status :complete
+:comment "all-in-one<br>overseas version of the PX-404A"
+
+:model "Stylus SX235W"
+:interface "USB"
+:usbid "0x04b8" "0x0885"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
:model "Stylus SX400"
:interface "USB"
:usbid "0x04b8" "0x084a"
@@ -1917,12 +2609,42 @@
:status :good
:comment "network interface probably supported<br>all-in-one"
+:model "Stylus SX420W Series"
+:interface "USB"
+:usbid "0x04b8" "0x0864"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "Stylus SX430W Series"
+:interface "USB"
+:usbid "0x04b8" "0x0880"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "Stylus SX440W Series"
+:interface "USB"
+:usbid "0x04b8" "0x0884"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
:model "Stylus SX510W Series"
:interface "USB"
:usbid "0x04b8" "0x0856"
:status :good
:comment "all-in-one<br>overseas version of the PX-502A"
+:model "Stylus SX525WD"
+:interface "USB"
+:usbid "0x04b8" "0x085e"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-503A"
+
+:model "Stylus SX535WD"
+:interface "USB"
+:usbid "0x04b8" "0x0891"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>overseas version of the PX-504A"
+
:model "Stylus SX600FW"
:interface "USB"
:usbid "0x04b8" "0x0847"
@@ -1932,8 +2654,14 @@
:model "Stylus SX610FW Series"
:interface "USB"
:usbid "0x04b8" "0x0855"
-:status :unsupported
-:comment "supported by the epkowa backend plus non-free interpreter"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-602F"
+
+:model "Stylus SX620FW Series"
+:interface "USB"
+:usbid "0x04b8" "0x085d"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
:model "Stylus Scan 2000"
:interface "USB"
@@ -1959,6 +2687,18 @@
:status :good
:comment "all-in-one<br>overseas version of the PX-402A"
+:model "Stylus TX120 Series"
+:interface "USB"
+:usbid "0x04b8" "0x085c"
+:status :complete
+:comment "all-in-one"
+
+:model "Stylus TX130 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0883"
+:status :complete
+:comment "all-in-one"
+
:model "Stylus TX200"
:interface "USB"
:usbid "0x04b8" "0x0849"
@@ -1983,6 +2723,24 @@
:status :good
:comment "all-in-one"
+:model "Stylus TX220 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0865"
+:status :complete
+:comment "all-in-one"
+
+:model "Stylus TX230W Series"
+:interface "USB"
+:usbid "0x04b8" "0x0885"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "Stylus TX235"
+:interface "USB"
+:usbid "0x04b8" "0x0881"
+:status :complete
+:comment "all-in-one<br>overseas version of the PX-404A"
+
:model "Stylus TX400"
:interface "USB"
:usbid "0x04b8" "0x084a"
@@ -1995,24 +2753,174 @@
:status :good
:comment "network interface probably supported<br>all-in-one"
+:model "Stylus TX420W Series"
+:interface "USB"
+:usbid "0x04b8" "0x0864"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "Stylus TX430W Series"
+:interface "USB"
+:usbid "0x04b8" "0x0880"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "Stylus TX435W"
+:interface "USB"
+:usbid "0x04b8" "0x0884"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
:model "Stylus TX550W Series"
:interface "USB"
:usbid "0x04b8" "0x0856"
:status :good
:comment "all-in-one<br>overseas version of the PX-502A"
+:model "Stylus TX560WD Series"
+:interface "USB"
+:usbid "0x04b8" "0x085e"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-503A"
+
+:model "WF-2510 Series"
+:interface "USB"
+:usbid "0x04b8" "0x08a5"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-505F"
+
+:model "WF-2520 Series"
+:interface "USB"
+:usbid "0x04b8" "0x08a6"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-535F"
+
+:model "WF-2530 Series"
+:interface "USB"
+:usbid "0x04b8" "0x08a6"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-535F"
+
+:model "WF-2540 Series"
+:interface "USB"
+:usbid "0x04b8" "0x08a6"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-535F"
+
+:model "WF-3520 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0899"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-605F"
+
+:model "WF-3530 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0899"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-675F"
+
+:model "WF-3540 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0899"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "WF-7510 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0869"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-1600F"
+
+:model "WF-7520 Series"
+:interface "USB"
+:usbid "0x04b8" "0x087c"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-1700F"
+
+:model "WF-M1560 Series"
+:interface "USB"
+:usbid "0x04b8" "0x08ab"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "WP-4511"
+:interface "USB"
+:usbid "0x04b8" "0x087d"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-B750F"
+
+:model "WP-4515"
+:interface "USB"
+:usbid "0x04b8" "0x087d"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "WP-4521"
+:interface "USB"
+:usbid "0x04b8" "0x087d"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-B750F"
+
+:model "WP-4525"
+:interface "USB"
+:usbid "0x04b8" "0x087d"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-B750F"
+
+:model "WP-4530 Series"
+:interface "USB"
+:usbid "0x04b8" "0x087d"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-B750F"
+
+:model "WP-4540 Series"
+:interface "USB"
+:usbid "0x04b8" "0x087d"
+:status :complete
+:comment "network interface option supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-B750F"
+
+:model "WP-4590 Series"
+:interface "USB"
+:usbid "0x04b8" "0x087e"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
:model "WorkForce 310 Series"
:interface "USB"
:usbid "0x04b8" "0x0854"
:status :good
:comment "all-in-one"
+:model "WorkForce 320 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0863"
+:status :complete
+:comment "network interface (option) supported via DFSG non-free iscan-network-nt package<br>some models in the series have a built-in network interface<br>all-in-one"
+
+:model "WorkForce 435"
+:interface "USB"
+:usbid "0x04b8" "0x0870"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
:model "WorkForce 500"
:interface "USB"
:usbid "0x04b8" "0x084c"
:status :good
:comment "all-in-one"
+:model "WorkForce 520 Series"
+:interface "USB"
+:usbid "0x04b8" "0x085f"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "WorkForce 545"
+:interface "USB"
+:usbid "0x04b8" "0x0890"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
:model "WorkForce 600"
:interface "USB"
:usbid "0x04b8" "0x0847"
@@ -2022,6 +2930,166 @@
:model "WorkForce 610 Series"
:interface "USB"
:usbid "0x04b8" "0x0855"
-:status :unsupported
-:comment "supported by the epkowa backend plus non-free interpreter"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-602F"
+
+:model "WorkForce 625"
+:interface "USB"
+:usbid "0x04b8" "0x085e"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-503A"
+
+:model "WorkForce 630 Series"
+:interface "USB"
+:usbid "0x04b8" "0x085d"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "WorkForce 645"
+:interface "USB"
+:usbid "0x04b8" "0x088f"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "WorkForce 840 Series"
+:interface "USB"
+:usbid "0x04b8" "0x086a"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-673F"
+
+:model "WorkForce 845"
+:interface "USB"
+:usbid "0x04b8" "0x0892"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "WorkForce K301"
+:interface "USB"
+:usbid "0x04b8" "0x0872"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "XP-100 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0895"
+:status :complete
+:comment "all-in-one<br>overseas version of the PX-045A"
+
+:model "XP-200 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0896"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "XP-211"
+:interface "USB"
+:usbid "0x04b8" "0x08ae"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "XP-212"
+:interface "USB"
+:usbid "0x04b8" "0x08ae"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "XP-215"
+:interface "USB"
+:usbid "0x04b8" "0x08ae"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "XP-300 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0898"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-435A"
+
+:model "XP-310 Series"
+:interface "USB"
+:usbid "0x04b8" "0x08af"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package"
+
+:model "XP-400 Series"
+:interface "USB"
+:usbid "0x04b8" "0x0898"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the PX-435A"
+
+:model "XP-410 Series"
+:interface "USB"
+:usbid "0x04b8" "0x08b0"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "XP-600 Series"
+:interface "USB"
+:usbid "0x04b8" "0x089e"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-775A"
+
+:model "XP-700 Series"
+:interface "USB"
+:usbid "0x04b8" "0x089d"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one"
+
+:model "XP-750 Series"
+:interface "USB"
+:usbid "0x04b8" "0x089c"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-805A/EP-805AR/EP-805AW"
+
+:model "XP-800 Series"
+:interface "USB"
+:usbid "0x04b8" "0x089b"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-905A"
+
+:model "XP-850 Series"
+:interface "USB"
+:usbid "0x04b8" "0x089a"
+:status :complete
+:comment "network interface supported via DFSG non-free iscan-network-nt package<br>all-in-one<br>overseas version of the EP-905F"
+
+:model "Epson ME 350"
+:interface "USB"
+:usbid "0x04b8" "0x088d"
+:status :good
+
+:model "WP-M4525, WP-M4521, PX-K751F, WP-M4595"
+:interface "USB"
+:usbid "0x04b8" "0x08a7"
+:status :good
+
+:model "EP-976A3, XP-950"
+:interface "USB"
+:usbid "0x04b8" "0x08b3"
+:status :good
+
+:model "EP-906F, XP-810"
+:interface "USB"
+:usbid "0x04b8" "0x08b4"
+:status :good
+
+:model "EP-806A, XP-710"
+:interface "USB"
+:usbid "0x04b8" "0x08b5"
+:status :good
+
+:model "EP-776A, XP-610"
+:interface "USB"
+:usbid "0x04b8" "0x08b6"
+:status :good
+
+:model "EP-706A, XP-510"
+:interface "USB"
+:usbid "0x04b8" "0x08b7"
+:status :good
+
+:model "LP-M8040, LP-M8040A, LP-M8040F"
+:interface "USB"
+:usbid "0x04b8" "0x08ad"
+:status :good
diff --git a/doc/descriptions/fujitsu.desc b/doc/descriptions/fujitsu.desc
index 1691ad5..e74a7f6 100644
--- a/doc/descriptions/fujitsu.desc
+++ b/doc/descriptions/fujitsu.desc
@@ -12,9 +12,9 @@
:backend "fujitsu" ; name of backend
:url "http://www.thebility.com/fujitsu/"
-:version "117" ; version of backend
+:version "118" ; version of backend
:manpage "sane-fujitsu" ; name of manpage (if it exists)
-:comment "Backend updated for SANE release 1.0.24, see sane-fujitsu manpage"
+:comment "Backend updated for SANE release 1.0.25, see sane-fujitsu manpage"
:devicetype :scanner ; start of a list of devices....
; other types: :stillcam, :vidcam,
; :meta, :api
@@ -143,6 +143,18 @@
:usbid "0x04c5" "0x1150"
:comment "small, recent, discontinued"
+:model "fi-6130Z"
+:interface "USB"
+:status :complete
+:usbid "0x04c5" "0x11f3"
+:comment "small, recent, discontinued"
+
+:model "fi-6230Z"
+:interface "USB"
+:status :complete
+:usbid "0x04c5" "0x11f4"
+:comment "small, recent, discontinued"
+
:model "ScanSnap S1500"
:interface "USB"
:status :complete
@@ -173,16 +185,16 @@
:usbid "0x04c5" "0x11fc"
:comment "small, current"
-:model "fi-6130Z"
+:model "fi-7160"
:interface "USB"
:status :complete
-:usbid "0x04c5" "0x11f3"
+:usbid "0x04c5" "0x132e"
:comment "small, current"
-:model "fi-6230Z"
+:model "fi-7260"
:interface "USB"
:status :complete
-:usbid "0x04c5" "0x11f4"
+:usbid "0x04c5" "0x132f"
:comment "small, current"
:model "ScanSnap iX500"
@@ -311,6 +323,18 @@
:usbid "0x04c5" "0x11f2"
:comment "medium, current"
+:model "fi-7180"
+:interface "USB"
+:status :complete
+:usbid "0x04c5" "0x132c"
+:comment "medium, current"
+
+:model "fi-7280"
+:interface "USB"
+:status :complete
+:usbid "0x04c5" "0x132d"
+:comment "medium, current"
+
;==================================================
; DISCONTINUED OLDER MODELS, BIG
:model "M3099A"
diff --git a/doc/descriptions/genesys.desc b/doc/descriptions/genesys.desc
index 4cb2fc0..eb060f6 100644
--- a/doc/descriptions/genesys.desc
+++ b/doc/descriptions/genesys.desc
@@ -79,7 +79,7 @@
:model "ScanJet 4850C"
:interface "USB"
:usbid "0x03f0" "0x1b05"
-:status :untested
+:status :good
:comment "resolution from 100 to 2400 supported, UTA not supported yet"
:model "ScanJet G4010"
@@ -127,6 +127,12 @@
:usbid "0x04a9" "0x221c"
:status :good
+:model "CanoScan LiDE 80"
+:interface "USB"
+:usbid "0x04a9" "0x2214"
+:status :basic
+:comment "No 2400 dpi support, slow speed at lower resolution"
+
:model "CanoScan LiDE 100"
:interface "USB"
:usbid "0x04a9" "0x1904"
diff --git a/doc/descriptions/kodakaio.desc b/doc/descriptions/kodakaio.desc
index 7882513..5fb18ed 100644
--- a/doc/descriptions/kodakaio.desc
+++ b/doc/descriptions/kodakaio.desc
@@ -1,6 +1,6 @@
:backend "kodakaio"
:url "http://sourceforge.net/projects/cupsdriverkodak/"
-:version "2.4.6"
+:version "2.4.7"
:manpage "sane-kodakaio"
:comment "Backend for Kodak AiO ESP and Hero printers. Also possibly Advent AWL10"
:devicetype :scanner
diff --git a/doc/descriptions/pixma.desc b/doc/descriptions/pixma.desc
index 5983b0a..f354ada 100644
--- a/doc/descriptions/pixma.desc
+++ b/doc/descriptions/pixma.desc
@@ -11,7 +11,7 @@
; See doc/descriptions.txt for details.
:backend "pixma" ; name of backend
-:version "0.17.4" ; version of backend (or "unmaintained")
+:version "0.17.14" ; version of backend (or "unmaintained")
:manpage "sane-pixma" ; name of manpage (if it exists)
:url "http://home.arcor.de/wittawat/pixma/" ; 0.13.2 backend's web page
:url "http://mp610.blogspot.com/" ; the pixma backend blog
@@ -24,6 +24,18 @@
:mfg "Canon" ; name a manufacturer
:url "http://www.canon.com/"
+:model "PIXMA E400"
+:interface "USB"
+:usbid "0x04a9" "0x177a"
+:status :untested
+:comment "Testers needed!"
+
+:model "PIXMA E460 Series"
+:interface "USB"
+:usbid "0x04a9" "0x1788"
+:status :untested
+:comment "Testers needed!"
+
:model "PIXMA E500"
:interface "USB"
:usbid "0x04a9" "0x1758"
@@ -36,6 +48,12 @@
:status :untested
:comment "Testers needed!"
+:model "PIXMA E560"
+:interface "USB"
+:usbid "0x04a9" "0x177b"
+:status :untested
+:comment "Testers needed!"
+
:model "PIXMA E600"
:interface "USB"
:usbid "0x04a9" "0x175a"
@@ -63,8 +81,8 @@
:model "PIXMA MG2400 Series"
:interface "USB"
:usbid "0x04a9" "0x176c"
-:status :untested
-:comment "Testers needed!"
+:status :complete
+:comment "All resolutions supported (up to 600DPI)."
:model "PIXMA MG2500 Series"
:interface "USB"
@@ -72,23 +90,29 @@
:status :untested
:comment "Testers needed!"
+:model "PIXMA MG2900 Series"
+:interface "USB WiFi"
+:usbid "0x04a9" "0x1780"
+:status :complete
+:comment "All resolutions supported (up to 600DPI)."
+
:model "PIXMA MG3100 Series"
-:interface "USB WLAN"
+:interface "USB WiFi"
:usbid "0x04a9" "0x1752"
:status :complete
:comment "All resolutions supported (up to 1200DPI)."
:model "PIXMA MG3200 Series"
-:interface "USB"
+:interface "USB WiFi"
:usbid "0x04a9" "0x1762"
-:status :untested
-:comment "Testers needed!"
+:status :complete
+:comment "All resolutions supported (up to 1200DPI)."
:model "PIXMA MG3500 Series"
-:interface "USB"
+:interface "USB WiFi"
:usbid "0x04a9" "0x176e"
-:status :untested
-:comment "Testers needed!"
+:status :complete
+:comment "All resolutions supported (up to 1200DPI)."
:model "PIXMA MG4100 Series"
:interface "USB"
@@ -127,8 +151,14 @@
:comment "Testers needed!"
:model "PIXMA MG5500 Series"
-:interface "USB"
+:interface "USB WiFi"
:usbid "0x04a9" "0x1771"
+:status :complete
+:comment "All resolutions supported (up to 1200DPI)."
+
+:model "PIXMA MG5600 Series"
+:interface "USB"
+:usbid "0x04a9" "0x177f"
:status :untested
:comment "Testers needed!"
@@ -162,9 +192,21 @@
:status :untested
:comment "Testers needed!"
+:model "PIXMA MG6600 Series"
+:interface "USB"
+:usbid "0x04a9" "0x177e"
+:status :untested
+:comment "Testers needed!"
+
:model "PIXMA MG7100 Series"
:interface "USB"
:usbid "0x04a9" "0x1772"
+:status :complete
+:comment "All resolutions supported (up to 2400DPI)."
+
+:model "PIXMA MG7500 Series"
+:interface "USB"
+:usbid "0x04a9" "0x177c"
:status :untested
:comment "Testers needed!"
@@ -545,7 +587,7 @@
:interface "USB"
:usbid "0x04a9" "0x174d"
:status :complete
-:comment "Flatbed and ADF scan. All resolutions supported (up to 1200DPI). ADF empty buggy."
+:comment "Flatbed and ADF scan. All resolutions supported (up to 1200DPI)."
:model "PIXMA MX370 Series"
:interface "USB"
@@ -560,16 +602,16 @@
:comment "Testers needed!"
:model "PIXMA MX410"
-:interface "USB Ethernet"
+:interface "USB Ethernet WiFi"
:usbid "0x04a9" "0x174e"
-:status :untested
-:comment "Same protocol as Pixma MX420? Testers needed!"
+:status :complete
+:comment "Flatbed and ADF scan. All resolutions supported (up to 1200DPI)."
:model "PIXMA MX420"
:interface "USB Ethernet"
:usbid "0x04a9" "0x174f"
:status :complete
-:comment "Flatbed and ADF scan. All resolutions supported (up to 1200DPI). ADF empty buggy."
+:comment "Flatbed and ADF scan. All resolutions supported (up to 1200DPI)."
:model "PIXMA MX430 Series"
:interface "USB Ethernet"
@@ -583,17 +625,29 @@
:status :untested
:comment "Testers needed!"
-:model "PIXMA MX510 Series"
+:model "PIXMA MX470 Series"
:interface "USB Ethernet"
-:usbid "0x04a9" "0x175c"
+:usbid "0x04a9" "0x1774"
:status :untested
:comment "Testers needed!"
+:model "PIXMA MX510 Series"
+:interface "USB Ethernet"
+:usbid "0x04a9" "0x175c"
+:status :complete
+:comment "Flatbed and ADF scan. All resolutions supported (up to 1200DPI)."
+
:model "PIXMA MX520 Series"
-:interface "USB"
+:interface "USB Ethernet WiFi"
:usbid "0x04a9" "0x1769"
-:status :untested
-:comment "Testers needed!"
+:status :complete
+:comment "Flatbed and ADF scan. All resolutions supported (up to 1200DPI)."
+
+:model "PIXMA MX530 Series"
+:interface "USB WiFi"
+:usbid "0x04a9" "0x1775"
+:status :complete
+:comment "Flatbed and ADF scan. All resolutions supported (up to 1200DPI)."
:model "PIXMA MX700"
:interface "USB Ethernet"
@@ -608,10 +662,10 @@
:comment "Testers needed!"
:model "PIXMA MX720 Series"
-:interface "USB"
+:interface "USB Ethernet WiFi"
:usbid "0x04a9" "0x176a"
-:status :untested
-:comment "Testers needed!"
+:status :complete
+:comment "All resolutions supported (up to 2400DPI). Flatbed, ADF simplex and Duplex supported."
:model "PIXMA MX850"
:interface "USB Ethernet"
@@ -629,37 +683,37 @@
:interface "USB Ethernet"
:usbid "0x04a9" "0x1743"
:status :complete
-:comment "All resolutions supported (up to 2400DPI). Flatbed, ADF simplex and Duplex supported, ADF empty buggy."
+:comment "All resolutions supported (up to 2400DPI). Flatbed, ADF simplex and Duplex supported."
:model "PIXMA MX880 Series"
:interface "USB Ethernet"
:usbid "0x04a9" "0x1750"
:status :complete
-:comment "All resolutions supported (up to 2400DPI). Flatbed, ADF simplex and Duplex supported, ADF empty buggy."
+:comment "All resolutions supported (up to 2400DPI). Flatbed, ADF simplex and Duplex supported."
:model "PIXMA MX882"
:interface "USB Ethernet"
:usbid "0x04a9" "0x1750"
:status :complete
-:comment "All resolutions supported (up to 2400DPI). Flatbed, ADF simplex and Duplex supported, ADF empty buggy."
+:comment "All resolutions supported (up to 2400DPI). Flatbed, ADF simplex and Duplex supported."
:model "PIXMA MX885"
:interface "USB Ethernet"
:usbid "0x04a9" "0x1750"
:status :complete
-:comment "All resolutions supported (up to 2400DPI). Flatbed, ADF simplex and Duplex supported, ADF empty buggy."
+:comment "All resolutions supported (up to 2400DPI). Flatbed, ADF simplex and Duplex supported."
:model "PIXMA MX890 Series"
:interface "USB Ethernet"
:usbid "0x04a9" "0x175e"
:status :complete
-:comment "All resolutions supported (up to 2400DPI). Flatbed, ADF simplex and Duplex supported, ADF empty buggy."
+:comment "All resolutions supported (up to 2400DPI). Flatbed, ADF simplex and Duplex supported."
:model "PIXMA MX920 Series"
:interface "USB"
:usbid "0x04a9" "0x176b"
-:status :untested
-:comment "Testers needed!"
+:status :good
+:comment "All resolutions supported (up to 2400DPI). Flatbed, ADF simplex and Duplex supported."
:model "PIXMA MX7600"
:interface "USB Ethernet"
@@ -679,6 +733,12 @@
:status :complete
:comment "All resolutions supported (up to 600DPI). Flatbed, ADF simplex and Duplex supported."
+:model "imageCLASS D530"
+:interface "USB"
+:usbid "0x04a9" "0x2775"
+:status :complete
+:comment "All resolutions supported (up to 600DPI)"
+
:model "i-SENSYS MF3010"
:interface "USB Ethernet"
:usbid "0x04a9" "0x2759"
@@ -781,23 +841,17 @@
:status :good
:comment "Flatbed and ADF scan. All resolutions supported (up to 600DPI). ADF empty buggy."
-:model "i-SENSYS MF4550d"
+:model "i-SENSYS MF4500 Series"
:interface "USB"
:usbid "0x04a9" "0x2736"
:status :good
:comment "Flatbed and ADF scan. All resolutions supported (up to 600DPI)."
-:model "imageCLASS MF4770n"
-:interface "USB Ethernet"
-:usbid "0x04a9" "0x2774"
-:status :good
-:comment "Flatbed scan. All resolutions supported (up to 600DPI). ADF buggy."
-
:model "imageCLASS MF4570dw"
:interface "USB"
:usbid "0x04a9" "0x275a"
-:status :untested
-:comment "Testers needed!"
+:status :complete
+:comment "All resolutions supported (up to 600DPI)"
:model "imageCLASS MF4660"
:interface "USB"
@@ -811,6 +865,18 @@
:status :complete
:comment "Flatbed and ADF scan. All resolutions supported (up to 600DPI)"
+:model "i-SENSYS MF4700 Series"
+:interface "USB Ethernet"
+:usbid "0x04a9" "0x2774"
+:status :good
+:comment "Flatbed scan. All resolutions supported (up to 600DPI). ADF buggy."
+
+:model "i-SENSYS MF4800 Series"
+:interface "USB Ethernet"
+:usbid "0x04a9" "0x2773"
+:status :complete
+:comment "Flatbed and ADF scan. All resolutions supported (up to 600DPI). Ethernet buggy."
+
:model "imageCLASS MF5630"
:interface "USB"
:usbid "0x04a9" "0x264e"
@@ -877,6 +943,18 @@
:status :untested
:comment "Testers needed!"
+:model "i-SENSYS MF8200C Series"
+:interface "USB Ethernet"
+:usbid "0x04a9" "0x2779"
+:status :complete
+:comment "Flatbed and ADF scan. All resolutions supported (up to 600DPI). Note: document feeder does not have 600DPI capability."
+
+:model "i-SENSYS MF8500C Series"
+:interface "USB Ethernet"
+:usbid "0x04a9" "0x277a"
+:status :untested
+:comment "Same protocol as MF8200C Series? Testers needed!"
+
:model "imageRUNNER 1020/1024/1025"
:interface "USB"
:usbid "0x04a9" "0x26e6"
@@ -889,6 +967,30 @@
:status :untested
:comment "Testers needed!"
+:model "MAXIFY MB2000 Series"
+:interface "USB"
+:usbid "0x04a9" "0x1778"
+:status :untested
+:comment "Testers needed!"
+
+:model "MAXIFY MB2300 Series"
+:interface "USB"
+:usbid "0x04a9" "0x1779"
+:status :untested
+:comment "Testers needed!"
+
+:model "MAXIFY MB5000 Series"
+:interface "USB"
+:usbid "0x04a9" "0x1776"
+:status :untested
+:comment "Testers needed!"
+
+:model "MAXIFY MB5300 Series"
+:interface "USB"
+:usbid "0x04a9" "0x1777"
+:status :untested
+:comment "Testers needed!"
+
:model "CanoScan 8800F"
:interface "USB"
:usbid "0x04a9" "0x1901"
diff --git a/doc/descriptions/unsupported.desc b/doc/descriptions/unsupported.desc
index 4f59ebf..d7e4128 100644
--- a/doc/descriptions/unsupported.desc
+++ b/doc/descriptions/unsupported.desc
@@ -424,13 +424,6 @@
:status :unsupported
:comment "Philips chip. Backend started, see link"
-:model "CanoScan LiDE 80"
-:url "/unsupported/canon-lide-80.html"
-:interface "USB"
-:usbid "0x04a9" "0x2214"
-:status :unsupported
-:comment "GL841 based, to be added to genesys backend"
-
:model "CanoScan LiDE 90"
:url "/unsupported/canon-lide-90.html"
:interface "USB"
@@ -788,13 +781,6 @@
:status :unsupported
:comment "Not supported yet by SANE. See link for details."
-:model "ScanJet 2400c"
-:url "/unsupported/hp-scanjet-2400c.html"
-:interface "USB"
-:usbid "0x03f0" "0x0a01"
-:status :unsupported
-:comment "GL646 based, to be added to genesys backend"
-
:model "Photosmart C3180"
:url "/unsupported/hp-photosmart-3180.html"
:interface "USB"
@@ -821,13 +807,6 @@
:comment "Not supported. See ScanJet 4600 entry."
:status :unsupported
-:model "ScanJet 4850C"
-:url "/unsupported/hp-scanjet-4850.html"
-:interface "USB"
-:usbid "0x03f0" "0x1b05"
-:comment "GL841, maybe can be added to genesys backend "
-:status :unsupported
-
:model "ScanJet 4890C"
:url "/unsupported/hp-scanjet-4850.html"
:interface "USB"
diff --git a/doc/releases.txt b/doc/releases.txt
index 320c8a0..a1b5478 100644
--- a/doc/releases.txt
+++ b/doc/releases.txt
@@ -38,14 +38,19 @@ Making the release:
* unpack tar.gz in temporary directory
* make diff from last release by unpacking it also in temporary directory
and running e.g.
- diff -uNr sane-backends-1.0.14 sane-backends-1.0.15 > sane-backends-1.0.14-1.0.15.diff
+ diff -uNr sane-backends-1.0.23 sane-backends-1.0.24 > sane-backends-1.0.23-1.0.24.diff
* check that the diff applies cleanly to the old version
* gzip the diff
* install devel headers required to build optional backends (1284,gphoto,etc)
* check that the new version .tar.gz can be compiled
-* upload these files together with the .diff.gz to the FTP/HTTP servers
+* upload the .tar.gz, tar.gz.md5 and .diff.gz to the FTP/HTTP servers
(at the moment: alioth.debian.org, ftp files are in
/srv/alioth.debian.org/chroot/ftproot/pub/sane/ )
+ In the alioth web interface, you should upload the smallest file first,
+ since you don't get error messages until after an upload completes,
+ and you might need to change something.
+ You can add the larger files afterwards. You may have to split larger
+ files.
Announcing the release:
@@ -55,15 +60,15 @@ Announcing the release:
* rebuild sane-backends.html and sane-mfgs.html (make -C doc html-pages)
* use man2html from http://hydra.nac.uci.edu/indiv/ehood/man2html.html
to rebuild html man pages (make -C doc html-man) (no other version works)
-* add md5 sum to sane-md5sum.txt
+* add md5 sum to sane-md5sums.txt
* check and update platforms page (sane-support.html)
* add announcement to index.html
* git commit -a && git push
* check that website was updated automatically. if not, see:
- /org/alioth.debian.org/chroot/home/groups/sane/bin/update-htdocs.sh
+ /home/groups/sane/bin/update-htdocs.sh
* rebuild descriptions.db (make -C doc descriptions.db)
* scp doc/descriptions.db to alioth:
- /org/alioth.debian.org/chroot/home/groups/sane/search/release
+ /home/groups/sane/search/release
* write announcements sane-devel, maybe others (e.g. freshmeat),
include the md5 hash
diff --git a/doc/sane-cardscan.man b/doc/sane-cardscan.man
index 75cd161..7c081af 100644
--- a/doc/sane-cardscan.man
+++ b/doc/sane-cardscan.man
@@ -53,7 +53,7 @@ used by the backend:
.PP
"lines_per_block 16" (or other number from 1 to 32)
.RS
-Controls the number of lines of image data which will be aquired in each pass.
+Controls the number of lines of image data which will be acquired in each pass.
Older scanners will require this number set lower, often 1.
.RE
.PP
diff --git a/doc/sane-coolscan.man b/doc/sane-coolscan.man
index bf83014..5952039 100644
--- a/doc/sane-coolscan.man
+++ b/doc/sane-coolscan.man
@@ -39,7 +39,7 @@ permissions of that device, have a look at sane\-scsi.
Some SCSI-adapters and low-level SCSI drivers do not work correctly with this backend and the
Coolscan scanners. These systems hang when the autofocus command is send to the Scanner.
-To see a list of which card/driver combinations work or dont work have a look at:
+To see a list of which card/driver combinations work or don't work have a look at:
http://andreas.rick.free.fr/sane/autofocus.html.
diff --git a/doc/sane-epjitsu.man b/doc/sane-epjitsu.man
index 1e201c0..ebb87e1 100644
--- a/doc/sane-epjitsu.man
+++ b/doc/sane-epjitsu.man
@@ -1,4 +1,4 @@
-.TH sane\-epjitsu 5 "09 Feb 2010" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
+.TH sane\-epjitsu 5 "12 Jun 2014" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
.IX sane\-epjitsu
.SH NAME
@@ -7,10 +7,10 @@ sane\-epjitsu \- SANE backend for Epson-based Fujitsu USB scanners.
.SH DESCRIPTION
The
.B sane\-epjitsu
-library implements a SANE (Scanner Access Now Easy) backend which provides basic access the Fujitsu fi\-60F and ScanSnap S300/S1300 scanners.
+library implements a SANE (Scanner Access Now Easy) backend which provides basic access the Fujitsu fi\-60F/fi\-65F and ScanSnap S300/S1300/S1100 scanners.
.SH HARDWARE SUPPORT
-These scanners are fairly limited, only supporting a couple of modes and resolutions, and always scanning full width. The backend supports missing modes (binary, grayscale) in software, but makes no effort to offer intermediate resolutions or scan area controls. See
+These scanners are fairly limited, only supporting a couple of modes and resolutions, and always scanning full width. The backend supports missing modes (binary, grayscale) in software, but makes no effort to offer intermediate resolutions and only minimal scan area controls. See
.B KNOWN ISSUES.
This backend may support other scanners. If physical inspection reveals an Epson chipset, please contact the author for instructions on collecting a USB trace under Windows to verify.
@@ -84,13 +84,10 @@ The backend uses a single environment variable, SANE_DEBUG_EPJITSU, which enable
.SH KNOWN ISSUES
.PP
.RS
-No scan area options are exposed.
+Only limited scan area options are exposed.
.br
.br
-fi\-60F hardware grayscale mode is not used.
-.br
-.br
-The S1100 is not currently supported, but a patch is available.
+fi\-60F and fi\-65F hardware grayscale mode is not used.
.RE
.SH CREDITS
diff --git a/doc/sane-epson.man b/doc/sane-epson.man
index 3790df6..d474bb7 100644
--- a/doc/sane-epson.man
+++ b/doc/sane-epson.man
@@ -91,7 +91,7 @@ are "None", "Halftone A (Hard Tone)", "Halftone B (Soft Tone)", "Halftone C
The
.I \-\-dropout
-switch selects the so called dropout color. Vald options are None,
+switch selects the so called dropout color. Valid options are None,
Red, Green and Blue. The default is None. The dropout color is used for
monochrome scanning and selects the color that is not scanned. This can
be used to e.g. scan an original with a colored background.
@@ -269,7 +269,7 @@ environment variable controls the SCSI related debug level for this backend.
Only a value of 2 is supported.
.TP
.B SANE_EPSON_CMD_LVL
-This allows to override the function or command level that the backend
+This allows one to override the function or command level that the backend
uses to communicate with the scanner. The function level a scanner
supports is determined during the initialization of the device. If
the backend does not recognize the function level reported by the
diff --git a/doc/sane-epson2.man b/doc/sane-epson2.man
index 27ee34e..896b340 100644
--- a/doc/sane-epson2.man
+++ b/doc/sane-epson2.man
@@ -137,7 +137,7 @@ are "None", "Halftone A (Hard Tone)", "Halftone B (Soft Tone)", "Halftone C
The
.I \-\-dropout
-switch selects the so called dropout color. Vald options are None,
+switch selects the so called dropout color. Valid options are None,
Red, Green and Blue. The default is None. The dropout color is used for
monochrome scanning and selects the color that is not scanned. This can
be used to e.g. scan an original with a colored background.
@@ -323,7 +323,7 @@ backend. E.g., a value of 128 requests all debug output to be printed.
Smaller levels reduce verbosity.
.TP
.B SANE_EPSON2_CMD_LVL
-This allows to override the function or command level that the backend
+This allows one to override the function or command level that the backend
uses to communicate with the scanner. The function level a scanner
supports is determined during the initialization of the device. If
the backend does not recognize the function level reported by the
diff --git a/doc/sane-genesys.man b/doc/sane-genesys.man
index 0cd1ffb..2b96483 100644
--- a/doc/sane-genesys.man
+++ b/doc/sane-genesys.man
@@ -48,11 +48,17 @@ GL841, GL843, GL847 or GL124 chipset, you can try to add it to the backend.
.SH "CALIBRATION"
To give correct image quality, sheet fed scanners need to be calibrated using the
calibration sheet sold with the scanner. To do calibration, you must insert this target
-in the feeder then start calibration either by passing the --calibrate option to scanimage
+in the feeder then start calibration either by passing the \-\-calibrate option to scanimage
or by clicking on the available 'calibrate' button in the 'advanced options' in a graphical
frontend. The result of the calibration is stored in a file in the home directory of the user doing it.
If you plug the scanner in another machine or use it with another account, calibration
-will have to be redone.
+will have to be redone, unles you use the \-\-calibration\-file option.
+If no home directory is defined,
+USERAPPPROFILE will be used, then TMPDIR or TMP. If none of these directories exist, the backend will try
+to write in the current working directory. Flatbed scanners alos make use of the calibration file as a cache
+to avoid calibration before each scan. Calibration file name is the name of the scanner model if only
+one scanner is detected. In the case of several identical model, the file name will be the name
+of the logical USB device name.
.SH EXTRAS SCAN OPTIONS
@@ -69,13 +75,13 @@ whith brightness below that value will be scanned as black.
.B \-\-brightness value
.RS
- -100..100 (in steps of 1). Set the brightness enhancement. 0 for no enhancement, negative
+ \-100..100 (in steps of 1). Set the brightness enhancement. 0 for no enhancement, negative
values to decrease brigthness, and positive values to increase it.
.RE
.B \-\-contrast value
.RS
- -100..100 (in steps of 1). Set the contrast enhancement. 0 for no enhancement, negative
+ \-100..100 (in steps of 1). Set the contrast enhancement. 0 for no enhancement, negative
values to decrease contrast, and positive values to increase it.
.RE
@@ -112,9 +118,9 @@ next scan will happen.
.B \-\-calibration\-file
.RS
Specify the calibration file name to use. At least the directory containing the file
-must exist, since it won't be created. This allow to handle the case of several identical devices
-that would otherwise use the same calibration data. This option is disabled if the backend is ran
-as root.
+must exist, since it won't be created. This option is disabled if the backend is ran
+as root. It maybe used in case of sheet-fed scanners to share a calibration file for several
+users.
.RE
.PP
@@ -295,7 +301,7 @@ Alexey Osipov <simba@lerlan.ru> for HP2400 final support
Powersaving isn't implemented for gl646 based scanner. Dynamic (emulated from gray data and with dithering) isn't enabled for gl646 scanners. Hardware lineart is limited up to 600 dpi for gl847 based scanners, due to the way image sensors are built.
.br
.TP
-This backend will be much slower if not using libusb-1.0. So be sure that sane-backends is built with the --enable-libusb_1_0 option.
+This backend will be much slower if not using libusb\-1.0. So be sure that sane\-backends is built with the \-\-enable-libusb_1_0 option.
.br
.SH "BUGS"
diff --git a/doc/sane-gt68xx.man b/doc/sane-gt68xx.man
index 4296ed4..e3d29af 100644
--- a/doc/sane-gt68xx.man
+++ b/doc/sane-gt68xx.man
@@ -117,7 +117,7 @@ can set the "correct" name here.
.PP
The
.B afe
-option allows to set custom offset and gain values for the Analog FrontEnd of
+option allows one to set custom offset and gain values for the Analog FrontEnd of
the scanner. This option can be either used to select the AFE values if
automatic coarse calibration is disabled, or to make automatic coarse
calibration faster. For the latter usage, enable debug level 3 (see below),
diff --git a/doc/sane-kodakaio.man b/doc/sane-kodakaio.man
index e5303b6..40310ed 100644
--- a/doc/sane-kodakaio.man
+++ b/doc/sane-kodakaio.man
@@ -1,4 +1,4 @@
-.TH sane\-kodakaio 2.4 "17 Jun 2012" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
+.TH sane\-kodakaio 5 "17 Jun 2012" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
.IX sane\-kodakaio
.SH NAME
diff --git a/doc/sane-pixma.man b/doc/sane-pixma.man
index b108679..c780ba8 100644
--- a/doc/sane-pixma.man
+++ b/doc/sane-pixma.man
@@ -1,4 +1,4 @@
-.TH "sane\-pixma" "5" "24 Sep 2013" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
+.TH "sane\-pixma" "5" "29 Oct 2014" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
.IX sane\-pixma
.SH NAME
sane\-pixma \- SANE backend for Canon Multi-Function Printers and CanoScan Scanners
@@ -8,16 +8,18 @@ The
library implements a SANE (Scanner Access Now Easy) backend that provides
access to Canon PIXMA / i-SENSYS / imageCLASS / imageRUNNER multi-function
devices (All-in-one printers) and the Canon CanoScan Flatbed/TPU scanners.
-The backend implements both USB interface and network interface
-using Canon's BJNP protocol. The network interface supports scanners over
-IPv4 as well as IPv6.
+The backend implements both the USB interface and network interface
+(using Canon's BJNP and MFNP protocols). The network interface supports scanners
+over IPv4 as well as IPv6 (MFNP over IPv6 is untested).
.PP
Currently, the following models work with this backend:
.PP
.RS
-PIXMA MG2100, MG3100, MG4200, MG5100, MG5200, MG5300
+PIXMA MG2100, MG2400, MG2900, MG3100, MG3200, MG3500, MG4200
.br
-PIXMA MG6100, MG6200, MG6300, MG8200
+PIXMA MG5100, MG5200, MG5300, MG5500, MG6100, MG6200, MG6300
+.br
+PIXMA MG7100, MG8200
.br
PIXMA MP140, MP150, MP160, MP170, MP180, MP190
.br
@@ -39,9 +41,9 @@ PIXMA MP960, MP970, MP980, MP990
.br
PIXMA MX300, MX310, MX330, MX340, MX350, MX360, MX370
.br
-PIXMA MX420, MX700, MX7600
+PIXMA MX410, MX420, MX510, MX520, MX530, MX700, MX720, MX7600
.br
-PIXMA MX850, MX860, MX870, MX882, MX885, MX890
+PIXMA MX850, MX860, MX870, MX882, MX885, MX890, MX920
.br
imageCLASS MF3110, MF3240, MF4010, MF4018
.br
@@ -49,11 +51,13 @@ imageCLASS MF4120, MF4122, MF4140, MF4150
.br
imageCLASS MF4270, MF4350d, MF4370dn, MF4380dn
.br
-imageCLASS MF4410, MF4430, MF4660, MF4690, MF4770n
+imageCLASS MF4410, MF4430, MF4570dw, MF4660, MF4690
+.br
+imageCLASS MF5730, MF5770, MF6550, D420, D480, D530
.br
-imageCLASS MF5730, MF5770, MF6550, D420, D480
+i-SENSYS MF3010, MF4320d, MF4330d, MF4500 Series
.br
-i-SENSYS MF3010, MF4320d, MF4330d, MF4550d
+i-SENSYS MF4700 Series, MF4800 Series, MF8200C Series
.br
imageRUNNER 1020/1024/1025
.br
@@ -65,8 +69,6 @@ and must be switched off and on.
.PP
.RS
PIXMA MP760, MP770, MP780, MP790
-.br
-PIXMA MX360
.RE
.PP
The following models may use the same Pixma protocol as those listed
@@ -75,23 +77,23 @@ in the backend so that they get recognized and activated.
Feedback in the sane\-devel mailing list welcome.
.PP
.RS
-PIXMA E500, E510, E600, E610
+PIXMA E400, E460, E500, E510, E560, E600, E610
.br
-PIXMA MG2200, MG2400, MG2500, MG3200, MG4100, MG5400, MG5500
+PIXMA MG2200, MG2500, MG4100, MG5400, MG5600
.br
-PIXMA MG6400, MG6500, MG7100, MG8100
+PIXMA MG6400, MG6500, MG6600, MG7500, MG8100
.br
PIXMA MP375R, MP493, MP495, MP740
.br
-PIXMA MX320, MX390, MX410, MX430, MX450, MX510, MX520
+PIXMA MX320, MX390, MX430, MX450, MX470, MX710
.br
-PIXMA MX710, MX720, MX920
-.br
-imageCLASS MF4570dw, MF5630, MF5650, MF5750, MF8030, MF8170c
+imageCLASS MF5630, MF5650, MF5750, MF8030, MF8170c
.br
imageRUNNER 1133
.br
-i-SENSYS MF5880dn, MF6680dn
+i-SENSYS MF5880dn, MF6680dn, MF8500C Series
+.br
+MAXIFY MB2000, MB2300, MB5000, MB5300
.RE
.PP
\#The following models may use partly the same Pixma protocol as other devices
@@ -119,11 +121,14 @@ The backend supports:
.PP
The device name for USB devices is in the form pixma:xxxxyyyy_zzzzz
where x, y and z are vendor ID, product ID and serial number respectively.
+.PP
Example: pixma:04A91709_123456 is a MP150.
.PP
-Device names for BJNP devices is in the form pixma:aaaa_bbbbb
+Device names for BJNP/MFNP devices is in the form pixma:aaaa_bbbbb
where aaaa is the scanners model and bbbb is the hostname or ip-adress.
.PP
+Example: pixma:MF4800_192.168.1.45 is a MF4800 Series multi-function peripheral.
+.PP
This backend, based on cloning original Canon drivers protocols, is in
a production stage. Designed has been carried out without any applicable
manufacturer documentation, probably never available. However, we have tested
@@ -136,10 +141,10 @@ provides the following
\#.B experimental
options for button handling, i.e. the options might change in the future.
.br
-The button status can be polled i.e. with 'scanimage -A'.
+The button status can be polled i.e. with 'scanimage \-A'.
.br
Button scan is disabled on MAC OS X due to darwin libusb not handling
-timeouts in usb interrupt reads.
+timeouts in usb interrupt reads, but may work when using the network protocol.
.TP
.I button\-controlled
This option can be used by applications (like
@@ -154,7 +159,7 @@ first page in the scanner, press the button, then the next page, press
the button and so on. When you finished, press the gray-scan button. (For
MP150 you have to stop the frontend by pressing Ctrl-C for example.)
.TP
-.I button\-update
+.I button\-update (deprecated)
(write only) In the past this option was required to be set to force
reading of the button status for
.I button\-1
@@ -202,25 +207,36 @@ support dynamic loading).
.I @CONFIGDIR@/pixma.conf
The backend configuration file (see also description of
.B SANE_CONFIG_DIR
-below). The files contains an optional list of scanners. Normally only scanners
-that can not be auto-detected because they are on a different subnet shall be
-listed here. If your OS does not allow enumeration of interfaces (i.e. it does not
-support the getifaddrs() function) you may need to add your scanner here as well.
+below). The files contains an optional list of networked scanners. Normally
+only scanners that can not be auto-detected because they are on a different
+subnet shall be listed here. If your OS does not allow enumeration of
+interfaces (i.e. it does not support the getifaddrs() function) you may need
+to add your scanner here as well.
+.PP
Scanners shall be listed as:
.PP
.RS
-.I bjnp://<host>
+.I <method>://<host>[:port]
.RE
.RS
-where host is the hostname or IP address of the scanner, e.g. bjnp://10.0.1.4
+.PP
+where method indicates the protocol used (bjnp is used for inkjet multi-functionals
+and mfnp is used for laser multi-functionals).
+.PP
+host is the hostname or IP address of the scanner, e.g. bjnp://10.0.1.4
for IPv4, bjnp://[2001:888:118e:18e2:21e:8fff:fe36:b64a] for a literal
-IPv6-address or bjnp://myscanner.mydomain.org. Define each scanner on a new
-line.
+IPv6-address or bjnp://myscanner.mydomain.org for a hostname.
+.PP
+The port number is optional and in normally implied by the method.
+Port 8610 is the standard port for mfnp, 8612 for bjnp.
+.PP
+Define each scanner on a new line.
.SH USB SUPPORT
USB scanners will be auto-detected and require no configuration.
.SH NETWORKING SUPPORT
The pixma backend supports network scanners using the so called Canon BJNP
-protocol. Both IPv4 and IPv6 are supported.
+protocol and MFNP protocol. Both IPv4 and IPv6 are supported, but IPv6 is as
+yet untested with MFNP. Please report your results on the mailing list.
.PP
Configuration is normally not required.
The pixma backend will auto-detect your scanner if it is within
@@ -229,24 +245,27 @@ the same subnet as your computer if your OS does support this.
If your scanner can not be auto-detected, you can add it to the pixma
configuration file (see above).
.SH FIREWALLING FOR NETWORKED SCANNERS
-The sane pixma backend communicates with port 8612 on the scanner. So
-you will have to allow outgoing traffic TO port 8612 on the common subnet
-for scanning.
+The sane pixma backend communicates with port 8610 for MFNP or port 8612
+for BJNP on the scanner. So
+you will have to allow outgoing traffic TO port 8610 or 8612 on the
+common subnet for scanning.
.PP
Scanner detection is slightly more complicated. The pixma backend sends
a broadcast on all direct connected subnets it can find (provided your OS
allows for enumeration of all netowrk interfaces). The broadcast is sent FROM
-port 8612 TO port 8612 on the broadcast address of each interface.
+port 8612 TO port 8610 or 8612 on the broadcast address of each interface.
The outgoing packets will be allowed by the rule described above.
.PP
Responses from the scanner are sent back to the computer TO port 8612.
Connection tracking however does not see a match as the response does not come
from the broadcast address but from the scanners own address.
For automatic detection of your scanner, you will therefore have to allow
-incoming packets TO port 8612 on your computer.
+incoming packets TO port 8612 on your computer. This applies to both MFNP and
+BJNP.
.PP
-So in short: open the firewall for all traffic from your computer to port 8612
-AND to port 8612 to your computer.
+So in short: open the firewall for all traffic from your computer to port
+8610 (for MFNP) or 8612 (for BJNP)
+AND to port 8612 (for both BJNP and MFNP) to your computer.
.PP
With the firewall rules above there is no need to add the scanner to the
pixma.conf file, unless the scanner is on a network that is not directly
@@ -266,6 +285,8 @@ the verbosity and includes the information printed at the lower levels.
.br
3 print debug-level messages
.br
+4 print verbose debug-level messages
+.br
11 dump USB traffic
.br
21 full dump USB traffic
@@ -275,8 +296,8 @@ the verbosity and includes the information printed at the lower levels.
.B SANE_DEBUG_BJNP
If the library was compiled with debug support enabled, this environment
variable controls the debug level for the
-.B BJNP
-network protocol for this backend. Higher value increases
+.B BJNP and MFNP
+network protocols for this backend. Higher value increases
the verbosity and includes the information printed at the lower levels.
.RS
0 print nothing (default)
diff --git a/doc/sane-scsi.man b/doc/sane-scsi.man
index c1032ee..bcb7d77 100644
--- a/doc/sane-scsi.man
+++ b/doc/sane-scsi.man
@@ -28,7 +28,7 @@ for Epson scanners,
for HP scanners, etc.).
.PP
For some operating systems (e.g. Linux and OS/2), there is an alternate way of
-specifying scanner devices. This alternate way allows to identify scanners by
+specifying scanner devices. This alternate way allows one to identify scanners by
the SCSI vendor and model string and/or by the SCSI device address (consisting
of bus number, channel number, id, and logical unit number). The syntax for
specifying a scanner in this way is:
diff --git a/doc/sane-test.man b/doc/sane-test.man
index 41b9aa4..e582895 100644
--- a/doc/sane-test.man
+++ b/doc/sane-test.man
@@ -40,7 +40,7 @@ Setting option
.B hand\-scanner
results in the test-backend behaving like a hand-scanner. Hand-scanners do
not know the image height a priori. Instead, they return a height of \-1.
-Setting this option allows to test whether a frontend can handle this
+Setting this option allows one to test whether a frontend can handle this
correctly. This option also enables a fixed width of 11 cm.
.PP
Setting option
@@ -68,7 +68,7 @@ ADF will be "empty".
.SH SPECIAL OPTIONS
Option
.B test\-picture
-allows to set the image that's returned to the frontend. While "Solid white"
+allows one to set the image that's returned to the frontend. While "Solid white"
and "Solid black" are quite obvious, the other options need some more
explanation. Color patterns are used to determine if all modes and their
colors are represented correctly by the frontend. The grid should look like the
@@ -76,10 +76,10 @@ same in every mode and resolution. A table of all the test pictures can be
found at: http://www.meier\-geinitz.de/sane/test\-backend/test\-pictures.html.
.PP
If option
-.B invert\-endianess
+.B invert\-endianness
is set, the upper and lower bytes of image data in 16 bit modes are exchanged.
This option can be used to test the 16 bit modes of frontends, e.g. if the
-frontend uses the correct endianess.
+frontend uses the correct endianness.
.PP
If option
.B read\-limit
diff --git a/doc/sane-umax_pp.man b/doc/sane-umax_pp.man
index 2a8349d..09e6ea0 100644
--- a/doc/sane-umax_pp.man
+++ b/doc/sane-umax_pp.man
@@ -58,7 +58,7 @@ needs to run as root. To allow user access to the scanner
run the backend through the network interface (See saned(8) and sane\-net(5)).
A more relaxed solution (security wise) is to add suid bit to the frontend
(See chmod(1)).
-The backend drop root priviledges as soon as it can, right after gaining direct
+The backend drop root privileges as soon as it can, right after gaining direct
access to IO ports, which lessen risks when being root.
.SH "DEVICE NAMES"
@@ -100,7 +100,7 @@ root (*BSD and linux), or with 'IOPL=yes' on
OS/2
.PP
.RE
-\fBNOTE:\fR in all cases, you must have sufficient priviledges
+\fBNOTE:\fR in all cases, you must have sufficient privileges
to get access to the chosen device or address. Depending on the
security settings, devices may not be available for all users.
You have to change permissions on the dev/ppi* or /dev/parport* devices.
diff --git a/doc/sane-usb.man b/doc/sane-usb.man
index 5052e41..8237a8a 100644
--- a/doc/sane-usb.man
+++ b/doc/sane-usb.man
@@ -90,7 +90,7 @@ can be found on the SANE webpage
and the individual backend manpages.
.PP
Most backends can detect USB scanners automatically using "usb" configuration
-file lines. This method allows to identify scanners by the USB vendor and
+file lines. This method allows one to identify scanners by the USB vendor and
product numbers. The syntax for specifying a scanner this way is:
.PP
.RS
diff --git a/doc/sane.man b/doc/sane.man
index b062782..4fad9a9 100644
--- a/doc/sane.man
+++ b/doc/sane.man
@@ -429,7 +429,7 @@ for details.
.TP
.B plustek
The SANE plustek backend supports USB flatbed scanners that use the National
-Semiconductor LM983[1/2/3]-chipset aka Merlin. Scanners using this LM983x chips
+Semiconductor LM983[1/2/3] chipset aka Merlin. Scanners using this LM983x chips
include some models from Plustek, KYE/Genius, Hewlett-Packard, Mustek, Umax,
Epson, and Canon. See
.BR sane\-plustek (5)
diff --git a/doc/saned.man b/doc/saned.man
index d8e8983..8721b15 100644
--- a/doc/saned.man
+++ b/doc/saned.man
@@ -164,7 +164,7 @@ The configuration line normally looks like this:
.PP
.RS
sane\-port stream tcp nowait saned.saned @SBINDIR@/saned saned
-.E
+.RE
.PP
However, if your system uses
.BR tcpd (8)