From 1687222e1b9e74c89cafbb5910e72d8ec7bfd40f Mon Sep 17 00:00:00 2001 From: =?UTF-8?q?J=C3=B6rg=20Frings-F=C3=BCrst?= Date: Wed, 31 Jul 2019 16:59:49 +0200 Subject: New upstream version 1.0.28 --- doc/sane-plustek.man | 24 +++++++++--------------- 1 file changed, 9 insertions(+), 15 deletions(-) (limited to 'doc/sane-plustek.man') diff --git a/doc/sane-plustek.man b/doc/sane-plustek.man index a6bb993..2df85b6 100644 --- a/doc/sane-plustek.man +++ b/doc/sane-plustek.man @@ -1,4 +1,4 @@ -.TH sane\-plustek 5 "13 Feb 2013" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy" +.TH sane\-plustek 5 "03 Nov 2017" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy" .IX sane\-plustek .SH NAME sane\-plustek \- SANE backend for LM983[1/2/3] based @@ -241,7 +241,7 @@ The Options: option warmup t .RS .I t -specifies the warmup period in seconds, if set to \-1, the +specifies the warmup period in seconds, if set to \-1, the automatic warmup function will be used .RE .PP @@ -468,8 +468,6 @@ export SANE_DEBUG_PLUSTEK=10 .BR sane\-gt68xx (5), .br .I @DOCDIR@/plustek/Plustek-USB.changes -.br -.I http://www.gjaeger.de/scanner/plustek/ .SH "CONTACT AND BUG-REPORTS" Please send any information and bug-reports to: @@ -482,16 +480,12 @@ Mailing-List archive at: .br .B http://www.sane\-project.org/mailing\-lists.html .PP -or directly from the projects' homepage at: -.br -.B http://www.gjaeger.de/scanner/plustek/ -.PP To obtain debug messages from the backend, please set the environment-variable .I SANE_DEBUG_PLUSTEK -before calling your favorite scan-frontend (i.e. xscanimage). +before calling your favorite scan-frontend (i.e. scanimage). .br -.B i.e.: export SANE_DEBUG_PLUSTEK=20 ; xscanimage +.B i.e.: export SANE_DEBUG_PLUSTEK=20 ; scanimage .PP The value controls the verbosity of the backend. Please note, that values greater than 24 force the backend to output raw data files, @@ -505,13 +499,13 @@ For problem reports it should be enough the set the verbosity to * The driver does not support these manic scalings up to 16 times the physical resolution. The only scaling is done on resolutions between the physical resolution -of the CCD-/CIS-sensor and the stepper motor i.e. you -have a 600x1200 dpi scanner and you are scanning using -800dpi, so scaling is necessary, because the sensor only -delivers 600dpi but the motor is capable to perform +of the CCD-/CIS-sensor and the stepper motor i.e. you +have a 600x1200 dpi scanner and you are scanning using +800dpi, so scaling is necessary, because the sensor only +delivers 600dpi but the motor is capable to perform 1200dpi steps. .PP -* Plusteks' model policy is somewhat inconsistent. They +* Plusteks' model policy is somewhat inconsistent. They sell technically different devices under the same product name. Therefore it is possible that some devices like the UT12 or U12 won't work \- please check -- cgit v1.2.3