1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
|
How to configure, build, and install SANE.
Introduction:
=============
SANE stands for Scanner Access Now Easy.
This package contains the SANE libraries (this means backends and
network scanning parts) and the command line frontend scanimage.
You always find the most recent version of SANE on:
http://www.sane-project.org/
At the same location there are also links to snapshots of the Git server and
sometimes beta releases of sane-backends. These are unstable development
versions, so be careful when using them. Please report any problems to us. See
contact section for details.
There are several graphical frontends available for SANE, see the list at
http://www.sane-project.org/sane-frontends.html.
Quick install:
==============
./autogen.sh # only if you just cloned the git repository
./configure
make
make install
man sane
Prerequisites
=============
In order to build SANE, the following tools and libraries are required:
- GNU make: version 3.70 or newer
- ISO C99 compiler: GNU C (gcc) is recommended for best results,
but any ISO C99 compliant compiler should do
Some more libraries are not strictly necessary to compile SANE, but some
functionality may be lost if they are not available. Make sure that these
libraries and their respective header files are available before running
configure. On some Linux distributions the header files are part of separate
packages (e.g. usb.h in libusb-devel or libusb-dev). These must also be
installed.
- libusb: Strongly recommended if you use a USB scanner.
Some backends won't work without libusb at all.
- libjpeg (>=6B): For the dc210, dc240, and gphoto2 backends.
- libieee1284 (>=0.1.5): For some parallel port backends.
- libgphoto2 (>=2.0): For the gphoto2 backend.
- a C++11 compliant C++ compiler for the genesys backend.
If you got the source straight from the git repository, as opposed to
a source tarball, you will need a few more utilities. These utilities
should normally *not* be needed for source archives downloaded from
the project's website at http://www.sane-project.org/.
- autoconf (>= 2.69) as well as the autoconf-archive (for the
AX_CXX_COMPILE_STDCXX and AX_CXX_COMPILE_STDCXX_11 macros)
- automake (>=1.15)
- libtool (>=2.4.6)
- gettext (>=0.19.8)
- git (>= 2.1.4)
SANE should build on most Unix-like systems. Support for OS/2, MacOS X, BeOS,
and Microsoft Windows is also available. For more details look at the
operating system specific README.* files. For a detailed support matrix, see:
http://www.sane-project.org/sane-support.html
This table may be out of date. Please tell us about any corrections or
additions. Please mention your operating system and platform and all the other
details mentioned in the table. See also the contact section.
Please check that there aren't any older versions of SANE installed on your
system. Especially if SANE libraries are installed in a different prefix
directory (e.g. /usr/lib/) this may cause problems with external
frontends. Please remove these libraries (libsane.*, sane/libsane-*) by using
your package manager or manually before installing this version of SANE.
Configuration
=============
Simply invoke configure in the top-level directory. Besides the usual GNU
configure options, there are the following SANE specific options:
--disable-shared
Don't use shared libraries. Useful for debugging or when there
is a problem building shared libraries. This implicitly turns
on --disable-dynamic --enable-static as well.
--disable-dynamic
Disable dynamic loading of backends (in the dll backend).
configure normally turns on dynamic loading when it
can find the appropriate header files and libraries
(<dlfcn.h> and -ldl).
--enable-static
Use static libraries (turned off by default).
--enable-preload
Preload backends into DLL backend. This is useful for debugging,
when dynamic loading is unavailable, to reduce runtime linking
overheads, or when you only want to distribute a single DLL with
all backends available. If dynamic loading or shared libraries are
unavailable or disabled, this option is turned on automatically.
--enable-scsibuffersize=N
Specify the buffer size of the buffer for SCSI commands. The default
value is 131072 bytes (128 kb). This may be changed at runtime by
setting the environment variable SANE_SG_BUFFERSIZE to the desired
value. The option is Linux-only at this time.
--enable-scsibuffersize and SANE_SG_BUFFERSIZE have no effect for
the Mustek, Umax and Sharp backends. For these backends, the buffer
size is set automatically and/or can be specified in the backend's
configuration file. Please refer to the backend's man pages for
details.
--enable-locking
Means, that some backends will use a lockfile for allowing multiple
access to one scanner. This is useful, i.e. one frontend is scanning
the button status and another one will scan. The path to the lock
files is define by --localstatedir at the configure step and is
$localstatedir/lock/sane. The default group is uucp and can be
changed by using --with-group=newgroup. If you do not want any
backend to use a lockfile, simply use --disable-locking.
To limit the backends that are compiled, set the variable BACKENDS to
the list of backends to compile. The following will limit compiling
to the epson2 and fujitsu backends:
./configure BACKENDS="epson2 fujitsu"
To limit the backends that are preloaded into the DLL, set the variable
PRELOADABLE_BACKENDS. The following will limit compiling to the epson2
and fujitsu backends but only preloads the epson2 backend:
./configure BACKENDS="epson2 fujitsu" PRELOADABLE_BACKENDS="epson2"
In addition to these configuration options, there are some more SANE-specific
options and many standard-options. To get a description of available options,
invoke configure with option --help.
If you plan on debugging one of the SANE programs, we recommend to run
configure like this:
CFLAGS="-g -O -Wall" ./configure --disable-shared
For operating system specific information, look at the README.* files.
Build
=====
To build SANE, simply type "make" in the top-level directory.
To clean up the executables and libraries in the source directory, type "make
clean". To restore everything to the status after unpacking the package, type
"make distclean".
Installation and Configuration
==============================
Once the build has finished, install SANE with "make install". By
default, this will place the SANE libraries in /usr/local/lib/, the
configuration files in /usr/local/etc/sane.d/, and the manual pages in
/usr/local/man/. The location of these directories can be overridden
with configure options; see "configure --help" for details.
Before running any SANE program, read the PROBLEMS file in this directory.
For information on configuring and trouble-shooting the various SANE
components, please refer to the manual page sane(7).
The tools/ directory contains some small programs that may be helpful. They
are described in tools/README.
Removing
========
Type "make uninstall" to remove SANE from your system. This will also remove
older versions of SANE if they have been installed at the same prefix.
Warning: Your configuration files will be deleted also so make sure you have a
backup. By default the configuration files are located in the directory
/usr/local/etc/sane.d/.
Contact
=======
For questions and general discussion about SANE contact the sane-devel mailing
list. You must be subscribed to the list to send mail. See
http://www.sane-project.org/mailing-lists.html for details.
If you want to submit a bug report or feature request please use our bug
tracking system. See http://www.sane-project.org/bugs.html for details. You
may also contact the author of a specific backend directly. See the AUTHORS
file for a list of addresses.
|