1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
|
.TH sane\-canon_lide70 5 "22 Aug 2020" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
.IX sane\-canon_lide70
.SH NAME
sane\-canon_lide70 \- SANE backend for the Canon LiDE 70 and 600(F) USB flatbed scanners
.SH DESCRIPTION
The
.B canon_lide70
library implements a SANE (Scanner Access Now Easy) backend that
provides access to the Canon Inc. CanoScan LiDE 70 and 600(F)
flatbed scanners. The film unit of the LiDE 600F is not supported.
.PP
Due to Canon's unwillingness to provide scanner documentation, this
software was developed by analyzing the USB traffic of the Windows
XP driver. The precise meaning of the individual commands that are sent
to the scanner is known only to a very limited extent. Some sophistication
present in the Windows XP driver has been left out. There is, for example,
no active calibration.
.PP
Testers and reviewers are welcome. Send your bug reports and comments to
the sane\-devel mailing list
.IR <sane\-devel@alioth-lists.debian.net> .
.PP
.SH CONFIGURATION
The
.I @CONFIGDIR@/canon_lide70.conf
file identifies the LiDE 70 by its vendor code 0x04a9 and its
product code 0x2225. For the LiDE 600(f) the product code is 0x2224.
.SH BACKEND SPECIFIC OPTIONS
.B Scan Mode:
.TP
.B \-\-resolution 75|150|300|600|1200 [default 600]
Sets the resolution of the scanned image in dots per inch. Scanning at 1200 dpi
is not available on the LiDE 600(F) and it is very slow on the LiDE 70.
.TP
.B \-\-mode Color|Gray|Lineart [default: Color]
Selects the scan mode. Lineart means fully black and fully white pixels only.
.TP
.B \-\-threshold 0..100 (in steps of 1) [default 75]
Select minimum-brightness percentage to get a white point, relevant only for Lineart
.TP
.B \-\-non-blocking[=(yes|no)] [inactive]
This option has not yet been implemented. Scans are captured in a temporary file with a typical size of 100MB.
.PP
.B Geometry:
.TP
.B \-l 0..216.069 [default 0]
Top-left x position of scan area in millimeters.
.TP
.B \-t 0..297 [default 0]
Top-left y position of scan area in millimeters.
.TP
.B \-x 0..216.069 [default 80]
Width of scan-area in millimeters.
.TP
.B \-y 0..297 [default 100]
Height of scan-area in millimeters.
.SH FILES
.TP
.I @CONFIGDIR@/canon_lide70.conf
The backend configuration file
.TP
.I @LIBDIR@/libsane\-canon_lide70.a
The static library implementing this backend.
.TP
.I @LIBDIR@/libsane\-canon_lide70.so
The shared library implementing this backend (present on systems that
support dynamic loading).
.SH ENVIRONMENT
.TP
.B SANE_DEBUG_CANON_LIDE70
If the library was compiled with debug support enabled, this
environment variable controls the debug level for this backend. Higher
debug levels increase the verbosity of the output.
Example:
.br
SANE_DEBUG_CANON_LIDE70=128 scanimage > /dev/null
.SH KNOWN PROBLEMS
At low resolutions (75 and 150 dpi, implying high slider speeds)
the LiDE 70 misses the top one millimeter of the scan area. This can
be remedied by shifting the document one millimeter downward, in cases
where such precision matters. Note that
.BR xsane (1)
uses the 75 dpi mode for prescans. The problem is worse on the LiDE 600(F),
where the offset is five millimeters.
.PP
It is recommended that in
.BR xsane (1)
the gamma value be set to approximately 1.7
to get more realistic colors. This also wipes out some artifacts caused by
the lack of real calibration.
.SH "SEE ALSO"
.BR sane (7),
.BR sane\-usb (5),
.BR sane\-find\-scanner (1),
.BR scanimage (1),
.BR xsane (1),
.br
http://www.juergen-ernst.de/info_sane.html
.SH AUTHOR
pimvantend, building upon pioneering work by Juergen Ernst.
|