summaryrefslogtreecommitdiff
path: root/doc/sane-coolscan3.man
blob: 7c59f4347b86fc6df656af1f511ffb0919de6eb7 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
.TH sane\-coolscan3 5 "11 Jul 2008"  "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
.IX sane\-coolscan3
.SH NAME
sane\-coolscan3 \- SANE backend for Nikon Coolscan film scanners
.SH DESCRIPTION
The
.B sane\-coolscan3
library implements a SANE (Scanner Access Now Easy) backend that
provides access to Nikon Coolscan film scanners.  Some functions of this
backend should be considered
.B beta-quality
software. Most functions have been stable for a long time, but of
course new development can not and will not function properly from
the very first day.

.PP
At present, the following scanners are known to work with this backend:
.PP
.RS
.ft CR
.nf
Model:                       Connection Type
---------------------------  -------------------
LS-30 (Coolscan III)         SCSI
LS-40 ED (Coolscan IV)       USB
LS-50 ED (Coolscan V)        USB
LS-2000                      SCSI
LS-4000 ED                   IEEE 1394
LS-8000 ED                   IEEE 1394
.fi
.ft R
.RE

Please send mail to
.I sane-devel@alioth-lists.debian.net
to report successes or failures.

.SH OPTIONS
The options the backend supports can either be selected through command line
options to programs like
.BR scanimage (1)
or through GUI elements in
.BR xscanimage (1)
or
.BR xsane (1).

Valid command line options and their syntax can be listed by using:
.PP
.RS
scanimage \-\-help \-d coolscan3:<interface>:<device>
.RE
.PP
where <interface> and <device> specify the device in question, as in the
configuration file (see next section). The
.B \-d
parameter and its argument can be omitted to obtain information on the
first scanner identified. Use the command:
.PP
.RS
scanimage \-L
.RE
.PP
to list all devices recognized by your SANE installation.

The options should be fully described by the description or tooltips given by
frontend. Here is a description of some of the most important options, in the
syntax with which they must be supplied to
.BR scanimage (1):
.TP
.B \-\-frame <n>
This option specifies which frame to operate on, if a motorized film strip
feeder or APS adapter are used. The frame number
.I <n>
ranges from 1 to the number of frames available, which is sensed each time
the backend is initialized (usually each time you start the frontend).
.TP
.B \-\-subframe <x>
This option shifts the scan window by the specified amount (default
unit is mm).
.TP
.B \-\-infrared=yes/no
If set to "yes", the scanner will read the infrared channel, thus allowing
defect removal in software. The infrared image is read during a second scan,
with no options altered. The backend must not be restarted between the scans.
If you use scanimage, perform a batch scan with
.B \-\-batch\-count=2
to obtain the IR information.
.TP
.B \-\-depth <n>
Here <n> can either be 8 or the maximum number of bits supported by the
scanner (10, 12, or 14). It specifies whether or not the scanner reduces
the scanned data to 8 bits before sending it to the backend. If 8 bits are
used, some information and thus image quality is lost, but the amount of data
is smaller compared to higher depths. Also, many imaging programs and image
formats cannot handle depths greater than 8 bits.
.TP
.B \-\-autofocus
Perform autofocus operation. Unless otherwise specified by the other options (
.B \-\-focus\-on\-centre
and friends), focusing is performed on the centre of the selected scan area.
.TP
.B \-\-ae\-wb
.TP
.B \-\-ae
Perform a pre-scan to calculate exposure values automatically.
.B \-\-ae\-wb
will maintain the white balance, while
.B \-\-ae
will adjust each channel separately.
.TP
.B \-\-exposure
Multiply all exposure times with this value. This allows exposure
correction without modifying white balance.
.TP
.B \-\-load
Load the next slide when using the slide loader (SF\-200 bulk loader only).
.TP
.B \-\-eject
Eject the film strip or mounted slide when using the slide loader.
.TP
.B \-\-reset
Reset scanner. The scanner will perform the same action as when power is
turned on: it will eject the film strip (with the SF\-200 bulk loader)
and calibrate itself. Use this
whenever the scanner refuses to load a film strip properly, as a result of
which
.B \-\-eject
does not work.

.SH CONFIGURATION FILE
The configuration file
.I @CONFIGDIR@/coolscan3.conf
specifies the device(s) that the backend will use. Owing to the nature of
the supported connection types SCSI, USB, and IEEE 1394, the default
configuration file supplied with the SANE distribution should work without
being edited.

Each line in the configuration file is either of the following, where all
entries are case-sensitive:
.TP
.I blank or starting with a '#' character
These lines are ignored, thus '#' can be used to include comments.
.TP
.I containing only the word """auto"""
This instructs the backend to probe for a scanner by scanning the buses for
devices with known identifiers. This is the default action when no
configuration file is present.
.TP
.I a line of the form <interface>:<device>
Here <interface> can be one of "scsi" or "usb", and <device> is the device
file of the scanner. Note that IEEE 1394 devices are handled by the SBP-2
module in the kernel and appear to SANE as SCSI devices.

.SH FILES
.TP
.I @LIBDIR@/libsane\-coolscan3.a
The static library implementing this backend.
.TP
.I @LIBDIR@/libsane\-coolscan3.so
The shared library implementing this backend (present on systems that
support dynamic loading).
.TP
.I @CONFIGDIR@/coolscan3.conf
Configuration file for this backend, read each time the backend is
initialized.

.SH ENVIRONMENT
.TP
.B SANE_DEBUG_COOLSCAN3
If the library was compiled with debug support enabled, this
environment variable controls the debug level for this backend.  E.g.,
a value of 128 requests all debug output to be printed.  Smaller
levels reduce verbosity.

.SH "SEE ALSO"
.BR sane\-scsi (5),
.BR sane\-usb (5),
.BR scanimage (1),
.BR xscanimage (1),
.BR xsane (1)

.SH BUGS
Currently, the SANE protocol does not allow automatically updating options
whenever the hardware changes. Thus the number of choices for the
.B \-\-frame
option will be fixed when the backend is initialized (usually when the user
runs the frontend). In particular, if there is no film strip in the
automatic film strip feeder when the backend is initialized, the
.B \-\-frame
option will not appear at all.
Also, restarting the frontend after swapping film adapters is strongly recommended.

Linux kernels prior to 2.4.19 had a patch that truncated INQUIRY data
from IEEE 1394 scanners to 36 bytes, discarding vital information
about the scanner. The IEEE 1394 models therefore only work with
2.4.19 or later.

No real bugs currently known, please report any to the SANE developers' list.

.SH AUTHORS
coolscan3 written by A. Zummo
.RI < a.zummo@towertech.it >,
based heavily on coolscan2 written by Andr\['a]s Major
.RI < andras@users.sourceforge.net >.