summaryrefslogtreecommitdiff
path: root/doc/sane-microtek.man
blob: 674f0bdc0acc92afb283cd8ac1ea5a5c1575d38b (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
.TH sane\-microtek 5 "13 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
.IX sane\-microtek
.SH NAME
sane\-microtek \- SANE backend for Microtek scanners
.SH DESCRIPTION
The
.B sane\-microtek
library implements a SANE (Scanner Access Now Easy) backend that
provides access to the "second generation" Microtek scanners.  At present,
the following hardware is known to work with this backend:
.PP
.RS
Microtek ScanMaker E2, E3, E6
.br
Microtek ScanMaker II, IIG, IIHR, IISP, III
.br
Microtek ScanMaker 35t, 35t+, 45t
.br
Microtek ScanMaker 600GS, 600ZS (see bug notes)
.br
Agfa StudioScan
.br
Agfa StudioScan II, StudioScan IIsi
.br
Agfa Arcus II (but not the "Arcus")
.br
Agfa DuoScan (preliminary)
.br
Vobis "Highscreen Realscan"
.br
Microtek Color PageWiz (preliminary)
.br
.PP
Transparent Media Adapter
.br
Document AutoFeeder
.br
.RE
.PP
The driver supports line art, halftone, 8bpp gray, and 24bpp color scans
at normal and "expanded" resolutions (i.e. 1200x1200 on an E6), fast scans
for color previews, and downloadable gamma tables.
.PP
The supported scanners are all SCSI scanners.  However, some parallel
port models may work (under Linux), if they use a parport->scsi chip,
and if you can find a scsi->parport driver.  This is known to be the
case for the Color PageWiz.
.PP
The driver does
.B not
support the newest Microtek scanners, such as the V330 and V660, which use
a new and very different SCSI-II command set.  For those, try the alternate
.BR microtek2 (5)
backend.  Most non-SCSI scanners would use the new command set.  Most
scanners newer than the Scanmaker E6 would use the new command set.
.PP
If you own a Microtek scanner other than the ones listed above, tell us
what happens --- see the
.BR BUGS
section at the end of this document.
.PP
Although this manual page is generally updated with each release,
up-to-date information on new releases and extraneous helpful hints
are available from the backend homepage:
.br
.PP
.RS
.I http://www.mir.com/mtek/
.RE

.SH "DEVICE NAMES"
This backend expects device names of the form:
.PP
.RS
.I special
.RE
.PP
Where
.I special
is the UNIX path-name for the special device that corresponds to the
scanner.  The special device name must be a generic SCSI device or a
symlink to such a device.  Under Linux, such a device name could be
.I /dev/sga
or
.IR /dev/sge ,
for example.
.PP

.SH CONFIGURATION
The contents of the
.I microtek.conf
file is a list of device names that correspond to Microtek
scanners.  Empty lines and lines starting with a hash mark (#) are
ignored.  A sample configuration file is shown below:
.PP
.RS
/dev/scanner
.br
# this is a comment
.br
/dev/sge
.RE
.PP
The configuration file may also contain the special tokens
.I norealcal
or
.I noprecal.
.I norealcal
will disable the use of magic, undocumented scanner calibration commands
which are known to work on the E6, but may not work with other models.
.I noprecal
will disable logic which tries to avoid scanner precalibration.  This logic
would only have been activated if the magic calibration code was turned off.

.PP
.SH FILES
.TP
.I @CONFIGDIR@/microtek.conf
The backend configuration file (see also description of
.B SANE_CONFIG_DIR
below).
.TP
.I @LIBDIR@/libsane\-microtek.a
The static library implementing this backend.
.TP
.I @LIBDIR@/libsane\-microtek.so
The shared library implementing this backend (present on systems that
support dynamic loading).

.SH ENVIRONMENT
.TP
.B SANE_CONFIG_DIR
This environment variable specifies the list of directories that may
contain the configuration file.  On *NIX systems, the directories are
separated by a colon (`:'), under OS/2, they are separated by a
semi-colon (`;').  If this variable is not set, the configuration file
is searched in two default directories: first, the current working
directory (".") and then in
.IR @CONFIGDIR@ .
If the value of the
environment variable ends with the directory separator character, then
the default directories are searched after the explicitly specified
directories.  For example, setting
.B SANE_CONFIG_DIR
to "/tmp/config:" would result in directories
.IR "tmp/config" ,
.IR "." ,
and
.I "@CONFIGDIR@"
being searched (in this order).
.TP
.B SANE_DEBUG_MICROTEK
If the library was compiled with debugging support enabled, this
environment variable controls the debug level for this backend.
A value of 128 requests maximally copious debug output; smaller
levels reduce verbosity.

.SH "SEE ALSO"
.BR sane (7),
.BR sane\-scsi (5),
.BR sane\-microtek2 (5)

.SH AUTHOR
Matt Marjanovic

.SH BUGS
Known bugs/limitations are:
.PP
.RS
Brightness and contrast broken.
.br
The 600GS is grayscale only, and will lock up if you select color.
(Unfortunately, the 600GS and 600ZS are indistinguishable by software.)
.br
.RE
.PP
i.e. don't complain about these --- but if brightness and/or contrast
.B do
work for you, please tell me.
.PP
If your scanner locks up, try setting the
.I norealcal
or
.I noprecal
option in the configuration file (first one, then both), and see if it helps.
(If it does, report it.)
.PP
Send lengthy bug reports and new scanner information to
.IR mtek\-bugs@mir.com .
All bug reports and new scanner inquiries should include an error log file.
You can generate copious
stderr output by setting the
.B SANE_DEBUG_MICROTEK
environment variable described above.  For example:
.PP
.RS
setenv SANE_DEBUG_MICROTEK 128
.RE
.PP
More general comments, suggestions, and inquiries about frontends
or SANE should go to
.IR sane\-devel@alioth-lists.debian.net ,
the SANE Developers mailing list. Have a look at
.I http://www.sane\-project.org/mailing\-lists.html
concerning subscription to sane\-devel.