summaryrefslogtreecommitdiff
path: root/doc/sane-sm3840.man
blob: 58f07b0c965a781a4ca0cf49536a3941896b1498 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
.TH sane\-sm3840 5 "11 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
.IX sane\-sm3840
.SH NAME
sane\-sm3840 \- SANE backend for Microtek scanners with SCAN08 USB chip
.SH DESCRIPTION
The
.B sane\-sm3840
library implements a SANE (Scanner Access Now Easy) backend that
provides access to some Microtek scanners with the SCAN08
USB chip.
.PP
There exist backends for Microtek scanners with SCSI command set.
Refer to
.BR sane\-microtek (5)
and
.BR sane\-microtek2 (5)
for details.
.PP
There also exists a Microtek 3600 series driver, see
.BR sane\-sm3600 (5)
for details.
.PP
At present, the following
scanners are known positively to work with this backend:
.PP
.RS
.ft CR
.nf
Vendor     Product ID:     Remark:
--------   --------------  -----------
Microtek   ScanMaker 3840  All modes OK
Microtek   ScanMaker 4800  All modes OK
.fi
.ft R
.RE
.PP
If you own a Microtek scanner with the SCAN08 chip other than the ones
listed above, it may or may not work with SANE.  Feel free to contact the
backend author
.RI ( earle@ziplabel.com )
to report results with scanners not on the list.


.SH "FRONTEND OPTIONS"
.PP
The following options are supported by the
.BR sane\-sm3840
driver:
.TP
.B \-\-mode color|gray|lineart|halftone
Color or grayscale mode.

.TP
.B \-\-resolution 150|300|600|1200
Pixels per inch for scans.

.TP
.B \-\-depth 8|16
Note that the least significant bits of 16bpp mode may be noise.

.TP
.B \-\-brightness 1..4096
Higher numbers increase brightness of returned image.

.TP
.B \-\-contrast 0.1..9.9
Larger numbers decrease contrast of returned image.

.TP
.B \-\-lamp\-timeout 1..15
Time in minutes until the lamp is turned off after a scan.

.SH CONFIGURATION
This backend does not support a configuration file right now.

.SH FILES
.TP
.I @LIBDIR@/libsane\-sm3840.a
The static library implementing this backend.
.TP
.I @LIBDIR@/libsane\-sm3840.so
The shared library implementing this backend (present on systems that
support dynamic loading).


.SH ENVIRONMENT
.TP
.B SANE_DEBUG_SM3840
If the library was compiled with debug support enabled, this
environment variable controls the debug level for this backend.  E.g.,
a value of 128 requests all debug output to be printed.  Smaller
levels reduce verbosity. To see error messages on stderr set
.B SANE_DEBUG_SM3840
to 1.

.SH "SEE ALSO"
.BR sane (7),
.BR sane\-microtek (5),
.BR sane\-microtek2 (5),
.BR sane\-sm3600 (5)
.br
.I http://www.ziplabel.com/sm3840

.SH AUTHOR
Earle F. Philhower III
.RI < earle@ziplabel.com >