summaryrefslogtreecommitdiff
path: root/doc/saned.man
blob: d8e89835815caef88779fbe31f3fa6a138527296 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
.TH saned 8 "20 Apr 2009" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
.IX saned
.SH NAME
saned \- SANE network daemon
.SH SYNOPSIS
.B saned
.B [ \-a 
.I [ username ]
.B | \-d 
.I [ n ]
.B | \-s
.I [ n ]
.B | \-h
.B ]
.SH DESCRIPTION
.B saned
is the SANE (Scanner Access Now Easy) daemon that allows remote clients
to access image acquisition devices available on the local host.
.SH OPTIONS
.PP
The
.B \-a
flag requests that
.B saned
run in standalone daemon mode. In this mode, 
.B saned
will detach from the console and run in the background, listening for incoming
client connections; 
.B inetd
is not required for
.B saned
operations in this mode. If the optional
.B username
is given after
.B \-a
,
.B saned
will drop root privileges and run as this user (and group).
.PP
The
.B \-d
and
.B \-s
flags request that
.B saned
run in debug mode (as opposed to
.BR inetd (8)
daemon mode).  In this mode,
.B saned
explicitly waits for a connection request.  When compiled with
debugging enabled, these flags may be followed by a number to request
debug info. The larger the number, the more verbose the debug output.
E.g.,
.B \-d128
will request printing of all debug info. Debug level 0 means no debug output
at all. The default value is 2. If flag
.B \-d
is used, the debug messages will be printed to stderr while
.B \-s
requests using syslog.
.PP
If 
.B saned
is run from inetd, xinetd or systemd, no option can be given.
.PP
The
.B \-h
flag displays a short help message.
.SH CONFIGURATION
First and foremost: 
.B saned
is not intended to be exposed to the internet or other non-trusted
networks. Make sure that access is limited by tcpwrappers and/or a firewall
setup. Don't depend only on 
.BR saned 's
own authentication. Don't run
.B saned
as root if it's not necessary. And do
.B not
install
.B saned
as setuid root.
.PP
The 
.I saned.conf
configuration file contains both options for the daemon and the access
list.
.TP
\fBdata_portrange\fP = \fImin_port\fP - \fImax_port\fP
Specify the port range to use for the data connection. Pick a port
range between 1024 and 65535; don't pick a too large port range, as it
may have performance issues. Use this option if your \fBsaned\fP
server is sitting behind a firewall. If that firewall is a Linux
machine, we strongly recommend using the Netfilter
\fInf_conntrack_sane\fP module instead.
.PP
The access list is a list of host names, IP addresses or IP subnets
(CIDR notation) that are permitted to use local SANE devices. IPv6
addresses must be enclosed in brackets, and should always be specified
in their compressed form. Connections from localhost are always
permitted. Empty lines and lines starting with a hash mark (#) are
ignored. A line containing the single character ``+'' is interpreted
to match any hostname. This allows any remote machine to use your
scanner and may present a security risk, so this shouldn't be used
unless you know what you're doing.
.PP
A sample configuration file is shown below:
.PP
.RS
# Daemon options
.br
data_portrange = 10000 - 10100
.br
# Access list
.br
scan\-client.somedomain.firm
.br
# this is a comment
.br
192.168.0.1
.br
192.168.2.12/29
.br
[::1]
.br
[2001:db8:185e::42:12]/64
.RE
.PP
The case of the host names does not matter, so AHost.COM is considered
identical to ahost.com.
.SH SERVER DAEMON CONFIGURATION
For
.B saned
to work properly in its default mode of operation, it is also necessary to 
add the appropriate configuration for 
.I (x)inetd or systemd.
(see below).
Note that your inetd must support IPv6 if you
want to connect to saned over IPv6 ; xinetd, openbsd-inetd and systemd 
are known to support IPv6, check the documentation for your inetd daemon.
.PP
In the sections below the configuration for 
.I inetd, xinetd
and
.I systemd
are described in more detail.
.PP
For the configurations below it is necessary to add a line of the following 
form to
.IR /etc/services :
.PP
.RS
sane\-port 6566/tcp # SANE network scanner daemon
.RE
.PP
The official IANA short name for port 6566 is "sane\-port". The older name 
"sane" is now deprecated.
.SH INETD CONFIGURATION
It is required to add a single line to the inetd configuration file
.IR (/etc/inetd.conf)
.
.PP
The configuration line normally looks like this:
.PP
.RS
sane\-port stream tcp nowait saned.saned @SBINDIR@/saned saned
.E
.PP
However, if your system uses
.BR tcpd (8)
for additional security screening, you may want to disable saned
access control by putting ``+'' in
.IR saned.conf
and use a line of the following form in
.IR /etc/inetd.conf
instead:
.PP
.RS
sane\-port stream tcp nowait saned.saned /usr/sbin/tcpd @SBINDIR@/saned
.RE
.PP
Note that both examples assume that there is a
.B saned
group and a
.B saned
user.  If you follow this example, please make sure that the 
access permissions on the special device are set such that
.B saned
can access the scanner (the program generally needs read and
write access to scanner devices).
.SH XINETD CONFIGURATION
If xinetd is installed on your system instead of inetd the following example
for 
.I /etc/xinetd.conf 
may be helpful:
.PP
.RS
.ft CR
.nf
# default: off
# description: The sane server accepts requests 
# for network access to a local scanner via the
# network.
service sane\-port
{
   port        = 6566
   socket_type = stream
   wait        = no
   user        = saned
   group       = saned
   server      = @SBINDIR@/saned
}
.fi
.ft R
.RE
.SH SYSTEMD CONFIGURATION
for systemd we need to add 2 configuation files in 
.I /etc/systemd/system.
.PP
The first file we need to add here is called 
.I saned.socket. 
It shall have
the following contents:
.PP
.RS
.ft CR
.nf
[Unit]
Description=saned incoming socket

[Socket]
ListenStream=6566
Accept=yes
MaxConnections=1

[Install]
WantedBy=sockets.target
.fi
.ft R
.RE
.PP
The second file to be added is 
.I saned@.service 
with the following contents:
.PP
.RS
.ft CR
.nf
[Unit]
Description=Scanner Service
Requires=saned.socket

[Service]
ExecStart=/usr/sbin/saned
User=saned
Group=saned
StandardInput=null
StandardOutput=syslog
StandardError=syslog
# Environment=SANE_CONFIG_DIR=@CONFIGDIR@ SANE_DEBUG_DLL=255
.fi
.ft R
.RE
.PP
Is you need to set an environment variable for saned like
.B SANE_CONFIG_DIR
you will have to remove the # on the last line and set the variable 
appropriately.  Multiple variables can be set by separating the assignments 
by spaces as shown in the example above.
.PP
Unlike 
.I (x)inetd
systemd allows debugging output from backends set using
.B SANE_DEBUG_<backend_name> 
to be captured. With the service unit as described above, the debugging output is 
forwarded to the system log.
.SH FILES
.TP
.I /etc/hosts.equiv
The hosts listed in this file are permitted to access all local SANE
devices.  Caveat: this file imposes serious security risks and its use
is not recommended.
.TP
.I @CONFIGDIR@/saned.conf
Contains a list of hosts permitted to access local SANE devices (see
also description of
.B SANE_CONFIG_DIR
below).
.TP
.I @CONFIGDIR@/saned.users
If this file contains lines of the form

user:password:backend

access to the listed backends is restricted. A backend may be listed multiple
times for different user/password combinations. The server uses MD5 hashing
if supported by the client.
.SH ENVIRONMENT
.TP
.B SANE_CONFIG_DIR
This environment variable specifies the list of directories that may
contain the configuration file.  Under UNIX, the directories are
separated by a colon (`:'), under OS/2, they are separated by a
semi-colon (`;').  If this variable is not set, the configuration file
is searched in two default directories: first, the current working
directory (".") and then in @CONFIGDIR@.  If the value of the
environment variable ends with the directory separator character, then
the default directories are searched after the explicitly specified
directories.  For example, setting
.B SANE_CONFIG_DIR
to "/tmp/config:" would result in directories "tmp/config", ".", and
"@CONFIGDIR@" being searched (in this order).

.SH "SEE ALSO"
.BR sane (7),
.BR scanimage (1),
.BR xscanimage (1),
.BR xcam (1),
.BR sane\-dll (5),
.BR sane\-net (5),
.BR sane\-"backendname" (5)
.br
.I http://www.penguin-breeder.org/?page=sane\-net
.SH AUTHOR
David Mosberger