1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
|
BACKEND TECO1
Relisys RELI 2412 (no ADF, no transparency adapter)
single pass scanner - 300*1200 dpi - 8.5*14
Inquiry:
000: 06 00 02 02 30 00 00 10 52 45 4c 49 53 59 53 20 ....0...RELISYS
016: 56 4d 33 35 33 30 2b 20 20 20 20 20 20 20 20 20 VM3530+
032: 31 2e 30 38 31 2e 30 38 02 00 54 45 43 4f 20 56 1.081.08..TECO V
048: 4d 33 35 33 41 M353A
Inquiry page 0x82
000: 06 82 00 12 11 54 45 43 4f 20 56 4d 33 35 33 41 .....TECO VM353A
016: 20 56 31 2e 30 36 V1.06
AVEC Colour 2412
three pass scanner - 300*600 dpi - 8.5*14
000: 06 00 02 02 30 00 00 10 20 20 20 20 20 20 20 20 ....0...
016: 49 6d 61 67 65 20 53 63 61 6e 6e 65 72 20 20 20 Image Scanner
032: 31 2e 30 38 31 2e 30 38 02 00 54 45 43 4f 20 56 1.081.08..TECO V
048: 4d 33 35 32 41 M352A
Avec Color Office 2400 (no ADF, no transparency adapter)
three pass scanner - 300*600 dpi - 8.5*14
Inquiry:
000: 06 00 02 02 30 00 00 10 20 20 20 20 20 20 20 20 ....0...
016: 49 6d 61 67 65 20 53 63 61 6e 6e 65 72 20 20 20 Image Scanner
032: 32 2e 30 34 32 2e 30 34 02 00 54 45 43 4f 20 56 2.042.04..TECO V
048: 4d 33 35 32 30 M3520
Inquiry page 0x82
000: 06 82 00 12 11 54 45 43 4f 20 56 4d 33 35 32 30 .....TECO VM3520
016: 20 56 32 2e 30 34 V2.04
RELI 4830 (no ADF, with transparency adapter)
000: 06 00 02 02 30 00 00 10 52 45 4c 49 53 59 53 20 ....0...RELISYS
016: 52 45 4c 49 20 34 38 33 30 20 20 20 20 20 20 20 RELI 4830
032: 31 2e 30 33 31 2e 30 33 02 00 54 45 43 4f 20 56 1.031.03..TECO V
048: 4d 34 35 34 32 M4542
Inquiry page 0x82
000: 06 82 00 12 11 54 45 43 4f 20 56 4d 34 35 34 32 .....TECO VM4542
016: 20 56 31 2e 30 33 V1.03
Dextra DF-600P - VM3510
000: 06 00 02 02 24 00 00 10 44 46 2D 36 30 30 4D 20 ....$...DF-600M
016: 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
032: 31 2E 31 37 31 2E 31 37 02 1.171.17.
/*--------------------------------------------------------------------------*/
SCSI commands supported by the RELISYS VM3530+:
TEST UNIT READY
00 00 00 00 00 00
REQ SENSE
03 00 00 00 12 00
VENDOR-09
09 00 00 78 00 00
3-4 = length of data to receive. Always 30720 bytes.
Probably 12 lines of calibration at 300dpi.
8.5*300*12=30600
VENDOR-0E (?)
0E 00 00 00 00 00
Always follows VENDOR-09 command
INQUIRY:
12 00 00 00 35 00
12 01 82 00 21 00
standard inquiry
52 bytes - appears to never change
32-39: firmware version
42-52: real scanner name
page 0x82 (vendor specific) - real scanner name with version
0-3 = page header
4 = string length
5-21 = real scanner name with version
MODE SELECT
15 10 00 00 18 00
always sends:
00 00 00 00 00 00 00 08 00 00 00 00 00 00 00 01
03 06 02 00 00 01 00 00
SCAN
1B 00 00 00 00 00
SET WINDOW
24 00 00 00 00 00 00 00 63 00
Total length is 99
07 = length (99-8 = 91)
10-11 = X Resolution
12-13 = Y resolution
14-17 = X top left corner
18-21 = Y top left corner
22-25 = width (size in inches * 300)
26-29 = length (size in inches * 300)
31 = 0x80 ?
33 = scan mode
0x00 = black & white
0x02 = grayscale
0x05 = color
34 = bit depth? - invariants, always 8
36 = dither pattern - only for B&W
0x00 = line art
0x01 = 2 X 2
0x02 = 3 X 3
0x03 = 4 X 4 Bayer
0x04 = 4 X 4 Smooth
0x05 = 8 X 8 Bayer
0x06 = 8 X 8 Smooth
0x07 = 8 X 8 Horizontal
0x08 = 8 X 8 Vertical
37 =
0x80 = RIF (VM353A only?)
63 = calibration?
0x00 yes
0x02 no
81 = ??? transparency adapter
0x00 no
0x01 yes
93 =
0x80 = ? (seems to activate a contrast value on VM353A)
37, 55, 57, 59, 61, 65, 67, 69, 71, 73, 75, 77, 79 = 0x80
85, 89, 93, 97 = 0xff
READ
28 00 00 00 00 00 00 00 3E 00
6-8 = length
SEND
2A 00 03 00 00 02 00 04 00 00
2 = data type code
0x03 = gamma - 4*256 bytes
GET DATA BUFFER STATUS
34 01 00 00 00 00 00 00 12 00
1 = bit 1 is wait
7-8 allocation length
returned buffer is 0x10 bytes long.
0-2 = additional length (0x10-3 = 0x0D)
3 = reserved(?)
8 = ?
9-11 = filled data buffer
12-13 = number of lines (constant during a scan)
14-15 = bytes per line (constant during a scan)
/*--------------------------------------------------------------------------*/
Command sequence
(simplified, since the TWAIN driver seems to be quite stupid)
Get some info:
INQUIRY
INQUIRY page 0x82
Setup the scan:
TUR
MODE SELECT
SET WINDOWS
GET BUFFER STATUS
VENDOR-09
VENDOR-0E
SEND(10)
SET WINDOWS (same as the first one)
SCAN
loop until all data read:
GET BUFFER STATUS
READ(10) if any data available
park the CCD:
SET WINDOWS
SCAN
/*--------------------------------------------------------------------------*/
The vendor specific command 0x09 and 0x0e are issued by the windows driver to the AVEC 2400, but the scanner rejects them.
/*--------------------------------------------------------------------------*/
The Dextra DF600-P is a VM3510. It's older than the other scanner and
is a little more primitive. The driver recognizes its scsi id and fake
a more evolved one. The scan sequence is also simplified. The rest is