summaryrefslogtreecommitdiff
path: root/debian/man/dispcal.1
blob: 20e9442f6c4b0c4c39986ab62a333c31c7ae9c7c (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
.\" DO NOT MODIFY THIS FILE!  It was generated by help2man 1.44.1.
.TH CALIBRATE "1" "September 2014" "dispcal" "User Commands"
.SH NAME
Calibrate \- Calibrate a Display.
.SH DESCRIPTION
Calibrate a Display
.SH SYNOPSIS
.B dispcal 
.RB [options]\ outfile
.TP
\fB\-v\fR [n]
Verbose mode
.HP
\fB\-display\fR displayname Choose X11 display name
.TP
\fB\-d\fR n[,m]
Choose the display n from the following list (default 1)
Optionally choose different display m for VideoLUT access
.IP
1 = 'Screen 1, Output DVI\-I\-1 at 0, 0, width 1920, height 1080'
.TP
\fB\-dweb[\fR:port]
Display via a web server at port (default 8080)
.TP
\fB\-c\fR listno
Set communication port from the following list (default 1)
.IP
** No ports found **
.TP
\fB\-r\fR
Report on the calibrated display then exit
.TP
\fB\-R\fR
Report on the uncalibrated display then exit
.TP
\fB\-m\fR
Skip adjustment of the monitor controls
.TP
\fB\-o\fR [profile.icc]
Create fast matrix/shaper profile [different filename to outfile.icc]
.TP
\fB\-O\fR "description"
Fast ICC Profile Description string (Default "outfile")
.TP
\fB\-u\fR
Update previous calibration and (if \fB\-o\fR used) ICC profile VideoLUTs
.TP
\fB\-q\fR [vlmh]
Quality \- Very Low, Low, Medium (def), High
.TP
\fB\-p\fR
Use telephoto mode (ie. for a projector) (if available)
.TP
\fB\-t\fR [temp]
White Daylight locus target, optional target temperaturee in deg. K (deflt.)
.TP
\fB\-T\fR [temp]
White Black Body locus target, optional target temperaturee in deg. K
.TP
\fB\-w\fR x,y
Set the target white point as chromaticity coordinates
.TP
\fB\-b\fR bright
Set the target white brightness in cd/m^2
.TP
\fB\-g\fR gamma
Set the target response curve advertised gamma (Def. 2.4)
Use "\-gl" for L*a*b* curve
Use "\-gs" for sRGB curve
Use "\-g709" for REC 709 curve (should use \fB\-a\fR as well!)
Use "\-g240" for SMPTE 240M curve (should use \fB\-a\fR as well!)
Use "\-G2.4 \fB\-f0\fR" for BT.1886
.TP
\fB\-G\fR gamma
Set the target response curve actual technical gamma
.TP
\fB\-f\fR [degree]
Amount of black level accounted for with output offset (default all output offset)
.TP
\fB\-a\fR ambient
Use viewing condition adjustment for ambient in Lux
.TP
\fB\-k\fR factor
Amount to correct black hue, 0 = none, 1 = full, Default = Automatic
.TP
\fB\-A\fR rate
Rate of blending from neutral to black point. Default 4.0
.TP
\fB\-B\fR blkbright
Set the target black brightness in cd/m^2
.TP
\fB\-e\fR [n]
Run n verify passes on final curves
.TP
\fB\-z\fR
Run only verify pass on installed calibration curves
.TP
\fB\-P\fR ho,vo,ss[,vs]
Position test window and scale it
ho,vi: 0.0 = left/top, 0.5 = center, 1.0 = right/bottom etc.
ss: 0.5 = half, 1.0 = normal, 2.0 = double etc.
.TP
\fB\-F\fR
Fill whole screen with black background
.TP
\fB\-n\fR
Don't set override redirect on test window
.TP
\fB\-E\fR
Encode the test values for video range 16..235/255
.TP
\fB\-J\fR
Run instrument calibration first (used rarely)
.TP
\fB\-N\fR
Disable initial calibration of instrument if possible
.TP
\fB\-H\fR
Use high resolution spectrum mode (if available)
.TP
\fB\-X\fR file.ccmx
Apply Colorimeter Correction Matrix
.TP
\fB\-X\fR file.ccss
Use Colorimeter Calibration Spectral Samples for calibration
.TP
\fB\-Q\fR observ
Choose CIE Observer for spectrometer or CCSS colorimeter data:
1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2, 1964_10c
.TP
\fB\-I\fR b|w
Drift compensation, Black: \fB\-Ib\fR, White: \fB\-Iw\fR, Both: \fB\-Ibw\fR
.TP
\fB\-Y\fR R:rate
Override measured refresh rate with rate Hz
.TP
\fB\-Y\fR A
Use non\-adaptive integration time mode (if available).
.TP
\fB\-Y\fR p
Don't wait for the instrument to be placed on the display
.TP
\fB\-C\fR "command"
Invoke shell "command" each time a color is set
.TP
\fB\-M\fR "command"
Invoke shell "command" each time a color is measured
.TP
\fB\-W\fR n|h|x
Override serial port flow control: n = none, h = HW, x = Xon/Xoff
.TP
\fB\-D\fR [level]
Print debug diagnostics to stderr
.TP
inoutfile
Base name for created or updated .cal and .icc output files