summaryrefslogtreecommitdiff
path: root/doc/sane-coolscan3.man
diff options
context:
space:
mode:
authorJörg Frings-Fürst <debian@jff-webhosting.net>2019-07-31 17:00:20 +0200
committerJörg Frings-Fürst <debian@jff-webhosting.net>2019-07-31 17:00:20 +0200
commit3759ce55ba79b8d3b9d8ed247a252273ee7dade3 (patch)
treed69692a274dd1c7d0672e6bb7155a0fc106f9d49 /doc/sane-coolscan3.man
parentc8bd2513ecba169cff44c09c8058c36987357b18 (diff)
parent1687222e1b9e74c89cafbb5910e72d8ec7bfd40f (diff)
Update upstream source from tag 'upstream/1.0.28'
Update to upstream version '1.0.28' with Debian dir ec5bb298266630fc3801ff6dc0c258f6df7ba979
Diffstat (limited to 'doc/sane-coolscan3.man')
-rw-r--r--doc/sane-coolscan3.man27
1 files changed, 13 insertions, 14 deletions
diff --git a/doc/sane-coolscan3.man b/doc/sane-coolscan3.man
index 364d5ef..238f127 100644
--- a/doc/sane-coolscan3.man
+++ b/doc/sane-coolscan3.man
@@ -6,11 +6,11 @@ sane\-coolscan3 \- SANE backend for Nikon Coolscan film scanners
The
.B sane\-coolscan3
library implements a SANE (Scanner Access Now Easy) backend that
-provides access to Nikon Coolscan film scanners. Some functions of this
-backend should be considered
+provides access to Nikon Coolscan film scanners. Some functions of this
+backend should be considered
.B beta-quality
-software. Most functions have been stable for a long time, but of
-course new development can not and will not function properly from
+software. Most functions have been stable for a long time, but of
+course new development can not and will not function properly from
the very first day.
.PP
@@ -31,27 +31,27 @@ LS-8000 ED IEEE 1394
.ft R
.RE
-Please send mail to sane-devel@lists.alioth.debian.org to report successes
+Please send mail to sane-devel@alioth-lists.debian.net to report successes
or failures.
.SH OPTIONS
-The options the backend supports can either be selected through command line
+The options the backend supports can either be selected through command line
options to programs like scanimage or through GUI elements in xscanimage or xsane.
-Valid command line options and their syntax can be listed by using
+Valid command line options and their syntax can be listed by using
.RS
scanimage \-\-help \-d coolscan3:<interface>:<device>
.RE
where <interface> and <device> specify the device in question, as in the
configuration file (see next section). The \-d parameter and its argument
can be omitted to obtain information on the first scanner identified. Use
-the command
+the command
.RS
scanimage \-L
.RE
to list all devices recognized by your SANE installation.
-The options should be fully described by the description or tooltips given by
+The options should be fully described by the description or tooltips given by
frontend. Here is a description of some of the most important options, in the
syntax with which they must be supplied to scanimage:
.TP
@@ -69,7 +69,7 @@ unit is mm).
.I \-\-infrared=yes/no
If set to "yes", the scanner will read the infrared channel, thus allowing
defect removal in software. The infrared image is read during a second scan,
-with no options altered. The backend must not be restarted between the scans.
+with no options altered. The backend must not be restarted between the scans.
If you use scanimage, perform a batch scan with batch\-count=2 to obtain the
IR information.
.TP
@@ -109,7 +109,7 @@ Eject the film strip or mounted slide when using the slide loader.
Reset scanner. The scanner will perform the same action as when power is
turned on: it will eject the film strip and calibrate itself. Use this
whenever the scanner refuses to load a film strip properly, as a result of
-which
+which
.I \-\-eject
does not work.
@@ -126,7 +126,7 @@ entries are case-sensitive:
These lines are ignored, thus '#' can be used to include comments.
.TP
.I containing only the word """auto"""
-This instructs the backend to probe for a scanner by scanning the buses for
+This instructs the backend to probe for a scanner by scanning the buses for
devices with know identifiers. This is the action taken when no
configuration file is present.
.TP
@@ -178,5 +178,4 @@ No real bugs currently known, please report any to the SANE developers' list.
.SH AUTHORS
coolscan3 written by A. Zummo (a.zummo@towertech.it), based heavily on
-coolscan2 written by Andr\['a]s Major (andras@users.sourceforge.net).
-
+coolscan2 written by Andr\['a]s Major (andras@users.sourceforge.net).